cs.CVSep 15, 2026

One-Step Is Optimal: Unconditional Rectified Flows are Noise2Noise Denoisers, and Multi-Step Integration Provably Hurts---A Benchmark and Task-Based Detectability Study on Low-Dose CT

Authors: Timothy Sereda, Debesh Jha

Organizations: Department of Computer Science Biomedical Perception & Intelligence Lab University of South Dakota Vermillion, South Dakota, USA

Abstract

Iterative and generative denoisers are increasingly used under the assumption that multi-step refinement outperforms a single regression pass. We show the opposite for label-free denoising. An unconditional rectified flow trained on two noisy observations of the same signal, as in Noise2Noise, has a minimiser whose one-step readout is exactly the MMSE denoiser without requiring clean targets. In contrast, multi-step integration provably departs from the MMSE solution because the flow terminates at the noisy data distribution rather than the clean-signal distribution. This departure is exact in a tractable Gaussian model and is confirmed experimentally: one-step flow matches a direct regressor, whereas multi-step Euler integration progressively reduces fidelity. Counterintuitively, the degradation increases with training quality, as a better velocity field more faithfully transports samples toward the noisy terminal law. The key ingredient is therefore the decorrelated pairing, not the flow machinery: a one-step regressor trained on matched noisy pairs gives our best label-free result (+1.99+1.99,dB). We evaluate these findings on CTDenoiser, a controlled low-dose CT benchmark spanning five architectures and supervised, similarity-based, blind-spot, and per-image methods. Among label-free approaches, only correlated-noise-aware Noise2Sim improves over the noisy baseline, while Noise2Void is flat-to-negative because CT noise violates its pixel-independence assumption. Finally, although supervised denoisers gain approximately 44,dB PSNR, a channelized Hotelling observer shows reduced low-contrast lesion detectability, revealing clinically relevant degradation missed by PSNR and SSIM.

Figures & tables

Appendix figures & tables4 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Aug 5, 2026

Rethinking Pixel Mean Flows via Interval Denoiser

Modern diffusion and flow-based models are increasingly moving toward few-step, latent-free generation to bypass the computational overhead of multi-step sampling and the reconstruction bottlenecks of external autoencoders. We propose the Interval Denoiser, a theoretically rigorous framework for latent-free generation. Derived directly from the flow matching ODE, it establishes an exact analytical mapping for intermediate trajectory states. Unlike prior formulations, our prediction is shown to reside on a low-dimensional manifold across any time interval, making the regression tractable for a network operating directly on pixels. Furthermore, by avoiding empirical algebraic substitutions, our formulation correctly isolates the pure time derivative to prevent biased gradient evaluations and ensure exact first-order optimization. By analyzing this objective, we equip our framework with residual clipping and a time-sampling curriculum, enabling effective long-interval training and improving few-step performance. Trained from scratch on ImageNet 256x256, our model achieves an FID of 4.55 in one step (1-NFE) and 3.98 in two steps (2-NFE) without perceptual losses.
Jun 18, 2026

Flow Map Denoisers: Traversing the Distortion-Perception Plane for Inverse Problems

Image restoration faces a fundamental tradeoff: methods that minimize error produce blurry reconstructions, while those that maximize perceptual quality yield sharp but less faithful images. Existing approaches either commit to a single operating point on this distortion perception (DP) frontier or require paired-data supervision, auxiliary models, or hyperparameter tuning of the sampler to access different points. We show that flow map models, a recent extension of flow matching for few-step sampling that learns an average field, implicitly define a one-parameter family of denoisers that continuously spans the DP frontier. The lookahead parameter t acts as a control knob between the MMSE and perceptual regimes. For Gaussian targets, we prove that varying t exactly recovers the optimal DP frontier; for natural images, we observe similar behavior empirically. Within a Plug-and-Play solver, the same mechanism extends to general inverse problems, where it controls a tradeoff between perceptual alignment and data consistency. Despite the lack of exact optimality guarantees in this setting, a single trained flow map spans the DP tradeoff, matching or exceeding specialized baselines at both extremes. Extensive experiments on CelebA (128×128128\times 128) and AFHQ (256×256256\times 256) across several linear and nonlinear inverse tasks validate our findings.
Apr 16, 2026

RelativeFlow: Taming Medical Image Denoising Learning with Noisy Reference

Medical image denoising (MID) lacks absolutely clean images for supervision, leading to a noisy reference problem that fundamentally limits denoising performance. Existing simulated-supervised discriminative learning (SimSDL) and simulated-supervised generative learning (SimSGL) treat noisy references as clean targets, causing suboptimal convergence or reference-biased learning, while self-supervised learning (SSL) imposes restrictive noise assumptions that are seldom satisfied in realistic MID scenarios. We propose RelativeFlow, a flow matching framework that learns from heterogeneous noisy references and drives inputs from arbitrary quality levels toward a unified high-quality target. RelativeFlow reformulates flow matching by decomposing the absolute noise-to-clean mapping into relative noisier-to-noisy mappings, and realizes this formulation through two key components: 1) consistent transport (CoT), a displacement map that constrains relative flows to be components of and progressively compose a unified absolute flow, and 2) simulation-based velocity field (SVF), which constructs a learnable velocity field using modality-specific degradation operators to support different medical imaging modalities. Extensive experiments on Computed Tomography (CT) and Magnetic Resonance (MR) denoising demonstrate that RelativeFlow significantly outperforms existing methods, taming MID with noisy references.