cs.CVSep 15, 2026

One-Step Is Optimal: Unconditional Rectified Flows are Noise2Noise Denoisers, and Multi-Step Integration Provably Hurts---A Benchmark and Task-Based Detectability Study on Low-Dose CT

Authors: Timothy Sereda, Debesh Jha

Organizations: Department of Computer Science Biomedical Perception & Intelligence Lab University of South Dakota Vermillion, South Dakota, USA

Abstract

Iterative and generative denoisers are increasingly used under the assumption that multi-step refinement outperforms a single regression pass. We show the opposite for label-free denoising. An unconditional rectified flow trained on two noisy observations of the same signal, as in Noise2Noise, has a minimiser whose one-step readout is exactly the MMSE denoiser without requiring clean targets. In contrast, multi-step integration provably departs from the MMSE solution because the flow terminates at the noisy data distribution rather than the clean-signal distribution. This departure is exact in a tractable Gaussian model and is confirmed experimentally: one-step flow matches a direct regressor, whereas multi-step Euler integration progressively reduces fidelity. Counterintuitively, the degradation increases with training quality, as a better velocity field more faithfully transports samples toward the noisy terminal law. The key ingredient is therefore the decorrelated pairing, not the flow machinery: a one-step regressor trained on matched noisy pairs gives our best label-free result (+1.99+1.99,dB). We evaluate these findings on CTDenoiser, a controlled low-dose CT benchmark spanning five architectures and supervised, similarity-based, blind-spot, and per-image methods. Among label-free approaches, only correlated-noise-aware Noise2Sim improves over the noisy baseline, while Noise2Void is flat-to-negative because CT noise violates its pixel-independence assumption. Finally, although supervised denoisers gain approximately 44,dB PSNR, a channelized Hotelling observer shows reduced low-contrast lesion detectability, revealing clinically relevant degradation missed by PSNR and SSIM.

Figures & tables

Appendix figures & tables4 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

CardsList
  1. Rethinking Pixel Mean Flows via Interval Denoiser

    Aug 5, 2026Alexander Zaytsev, Dmitry Baranchuk, Alexander Korotin +1Flow MatchingImage Generation

  2. Flow Map Denoisers: Traversing the Distortion-Perception Plane for Inverse Problems

    Jun 18, 2026Nicolas Zilberstein, Morteza Mardani, Santiago SegarraFlow MatchingFlow Map Learning

  3. RelativeFlow: Taming Medical Image Denoising Learning with Noisy Reference

    Apr 16, 2026Yuxin Liu, Yiqing Dong, Wenxue Yu +4Flow MatchingImage Denoising