cs.LGSep 26, 2026

Phenomenon-Graph JEPA: Label-Efficient Representation Learning for Contactless Cardiorespiratory Sensing

Authors: Constantino Álvarez Casado, Nhi Nguyen, Mohammad Rakibur Rahman, Le Nguyen, Manuel Lage Cañellas, Sasan Sharifipour, Miguel Bordallo López

Organizations: Center for Machine Vision and Signal Analysis (CMVS), University of Oulu, Finland · Candour Ltd, Oulu, Finland

Abstract

Millimeter-wave (mmWave) radar and RGB-D cameras can record cardiac and respiratory waveforms continuously and without contact, but labeled recordings remain scarce because every label requires a supervised acquisition session. Self-supervised pretraining can exploit the unlabeled signals, yet contrastive methods depend on signal transformations and negative pairs whose validity is uncertain for cardiorespiratory data, where time warping changes breathing rate and distant windows can share the same physiological state. We present Phenomenon-Graph JEPA, a joint-embedding predictive architecture that learns from four processed one-dimensional streams without negative pairs or synthetic augmentation in its base configuration. Each stream is encoded by a temporal convolutional branch and a band-limited spectral branch. During pretraining, the model predicts stopped target embeddings along typed edges, which connect streams assigned to the same physiological phenomenon, and forward in time within a state episode. We treat this physiological typing as a testable hypothesis and compare it with wrong-edge and all-pairs prediction graphs. In the OMuSense-23 dataset, pretraining improves label-efficiency area over matched supervised training by 3.91 percentage points (95% interval 2.08 to 5.80, Holm-adjusted p = 0.006), and by 3.74 points under a second configuration evaluated on the same test participants. However, the wrong-edge and all-pairs controls do not establish a benefit from physiological typing. Optional Takens-inspired delay coordinates improve a validation comparison with learned history, whereas two wrist-only WESAD protocols do not establish a pretraining advantage. The study therefore separates the measured benefit of predictive representations from the physiological prior used to organize their training.

Figures & tables

Explore similar work

Jul 3, 2026

MorphologyFM: A Foundation Model for Morphology-Aware Representation Learning from ECG and Pulse Oximetry Waveforms

Foundation models have recently emerged as a powerful paradigm for learning transferable representations from large scale biomedical data, yet existing approaches for physiological waveforms primarily optimize reconstruction or forecasting objectives that do not explicitly preserve clinically meaningful waveform morphology. Electrocardiograms (ECGs) and pulse oximetry (SpO2) waveforms encode rich cardiovascular and hemodynamic information through their morphological structure. In this work, we introduce MorphologyFM, a multimodal foundation model pretrained on paired ECG and SpO2 waveforms from the MIMIC critical care database using a morphology aware self supervised learning objective. MorphologyFM combines morphology guided masking, cross modal representation learning, and contrastive latent alignment to learn representations that capture clinically relevant physiological structure without requiring manual annotations. We evaluate MorphologyFM across multiple downstream prediction tasks, including arrhythmia classification, hypoxemia prediction, mortality prediction, and length of stay estimation, demonstrating consistent improvements over representative self supervised learning methods, including Masked Autoencoders (MAE), contrastive learning, Barlow Twins, and Joint Embedding Predictive Architectures (JEPA). Furthermore, we show that jointly modeling ECG and SpO2 waveforms produces more transferable representations than single modality pretraining. Our results establish waveform morphology as a powerful inductive bias for self supervised physiological representation learning and introduce MorphologyFM as a general purpose foundation model for continuous physiological monitoring.
Aug 21, 2026

Capturing Cardiac Cyclicity through Phase-Equivariant Self-Supervised Learning

The cyclic structure of physiological processes offers a natural prior for self-supervised representation learning, and the cardiac cycle provides a particularly well-defined setting in which to exploit it. We derive a phase-equivariant self-supervised objective and introduce Winder, a joint-embedding architecture that organises representations into phase-invariant coordinates and phase-rotating harmonic subspaces. Its transport operator is fixed and closed-form, derived from the cycle's geometry rather than learned, and adds no parameters. Evaluated on PTB-XL under a frozen linear-probe protocol, Winder attains diagnostic accuracy within the range reported by state-of-the-art self-supervised methods at a ~1 M parameter footprint, while exhibiting phase-equivariant latent geometry. These findings demonstrate that explicitly encoding cardiac-phase symmetry can preserve diagnostically useful information while yielding a latent geometry that is legible, parameter-efficient, and directly tied to a measurable physiological quantity.
Aug 13, 2026

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.