Routine chest CT captures upper-abdominal structures that may contain clinically relevant incidental abnormalities. Detecting these findings requires feature extraction from organs with different spatial extents and attenuation patterns. We propose FD-AA, a lightweight organ-aware classification head adaptable for frozen 3-D CT encoders. Within each organ, an attenuation-aware module preserves sparse focal evidence, while masked generalized-mean pooling captures diffuse anomaly patterns. In seven abdominal organs, FD-AA with Pillar-0 achieved state-of-the-art (SOTA) performance in both the CT-RATE test set (AUC = 0.798) and the external RAD-ChestCT dataset (AUC = 0.713). More specifically, FD-AA improved macro AUC/AP from 0.763/0.346 to 0.798/0.405 over direct classification using frozen Pillar-0 only (p = 0.034/0.016). Such performance gain generalizes across multiple frozen encoders (AUC improvement on MedicalNet +9.8%, CT-CLIP +14.7%, ResNet +3.7%), demonstrating the effectiveness of FD-AA across different feature representations. These results support the effectiveness of integrating focal-diffuse aggregation with explicit HU evidence for incidental abdominal abnormality detection.

Figures & tables

Explore similar work

Apr 27, 2026cs.CV

EXACT: an explainable anomaly-aware vision foundation model for analysis of 3D chest CT

Chest computed tomography (CT) is central to the detection and management of thoracic disease, yet the growing scale and complexity of volumetric imaging increasingly exceed what can be addressed by scan-level prediction alone. Clinically useful AI for CT must not only recognize disease across the whole volume, but also localize abnormalities and provide interpretable visual evidence. Existing vision-language foundation models typically compress scans and reports into global image-text representations, limiting their ability to preserve spatial evidence and support clinically meaningful interpretation. Here we developed EXACT, an explainable anomaly-aware foundation model for three-dimensional chest CT that learns spatially resolved representations from paired clinical scans and radiology reports. EXACT was pre-trained on 25,692 CT-reports pairs using anatomy-aware weak supervision, jointly learning organ segmentation and multi-instance anomaly localization without manual voxel-level annotations. The resulting organ-specific anomaly-aware maps assign each voxel a disease-specific anomaly score confined to its corresponding anatomy, jointly encoding lesion extent and organ-level context. In retrospective multinational and multi-center evaluations, EXACT showed broad and consistent improvements across clinically relevant CT tasks, spanning multi-disease diagnosis, zero-shot anomaly localization, downstream adaptation, and visually grounded report generation, outperforming existing three-dimensional medical foundation models. By transforming routine clinical CT scans and free-text reports into explainable voxel-level representations, EXACT establishes a scalable paradigm for trustworthy volumetric medical AI.
May 9, 2026cs.CV

CT-IDP: Segmentation-Derived Quantitative Phenotypes for Interpretable Abdominal CT Disease Classification

In this retrospective multi-institutional study, a quantitative phenotyping framework, CT-IDP (CT Image-Derived Phenotypes) was developed on the MERLIN abdominal CT benchmark (training, validation, and test sets- 15,175, 5,018, and 5,082 studies, respectively) and externally evaluated on two independent dataset: Duke-Abdomen (2,000) and AMOS (1,107). Multi-organ segmentations were generated with TotalSegmentator and used to derive over 900 organ and compartment-level descriptors spanning morphometry, attenuation, and contextual/burden findings. Sparse disease-specific logistic regression with elastic-net regularization was trained on MERLIN and externally validated under a frozen specification. Performance was compared against a DINOv3-based vision-transformer baseline using AUC and average precision (AP), supported by phenotype-stratified audits and coefficient-level inspection. Macro-AUC for CT-IDP versus the baseline was 0.897 versus 0.880 on MERLIN, 0.877 versus 0.857 on the Duke-Abdomen dataset, and 0.780 versus 0.756 on AMOS.
Jun 3, 2026cs.CV

ORACLE-CT: Anatomy-Aware Support Pooling for CT Classification

Abdominal CT disease classification is challenging because each scan is a large 3D volume with many possible findings, while diagnostic evidence is often confined to specific organs or anatomical compartments. Most study-level classifiers aggregate encoder features using anatomy-agnostic pooling or attention, creating a mismatch between localized disease evidence and global evidence aggregation. We propose ORACLE--CT, an encoder-agnostic anatomy-aware aggregation framework that uses multi-organ segmentation to define label-specific anatomical supports and restrict attention pooling to relevant regions. The framework supports single-organ, multi-organ union, comparative, localized, and global support strategies. We evaluate ORACLE--CT with three encoder families: DINOv3, I3D--ResNet-121, and the radiology-native Pillar--0 encoder. Models are trained end-to-end on MERLIN and evaluated internally and under frozen external transfer to Duke--Abdomen and AMOS. Compared with global average pooling, support-masked pooling improved MERLIN macro-AUROC/AUPRC from 0.838/0.638 to 0.858/0.676 for DINOv3 and from 0.829/0.617 to 0.848/0.659 for I3D--ResNet-121. On harmonized 10-label external evaluation, DINOv3 improved on Duke--Abdomen from 0.802/0.628 to 0.835/0.683 and on AMOS from 0.742/0.313 to 0.762/0.350, with similar gains for I3D--ResNet-121. For Pillar--0, most gains came from learned attention, with smaller additional benefit from anatomical masking. ORACLE--CT improves discrimination and external robustness while preserving an auditable link between predictions and anatomical evidence.