cs.CVSep 29, 2026

You Cannot Recover What Was Never Measured: Quantifying the Information Ceiling of Ultra-Low-Field MRI Super-Resolution

Authors: Prathamesh Pradeep Khole, Shreya Handa, Utkarsh Gupta, Razvan Marinescu

Organizations: University of California, Santa Cruz · Johns Hopkins University

Abstract

Generative super-resolution models can turn portable 64 mT MRI into images that look like 3T scans, and the field evaluates them with PSNR, SSIM, and pixelwise uncertainty, most often on pairs built by synthetically degrading high-field images. Prior work acknowledges that these models hallucinate and that the problem is ill posed, but to our knowledge no study measures how much information about the individual subject the real low-field scan actually contains. We measure it. Using paired 64 mT and 3T scans of the same subjects from three public datasets, and a measurement protocol validated on tests whose correct answer is known in advance, we find that, judged over the whole brain, real 64 mT scans carry structure specific to the individual only down to approximately 3 to 4 mm half-pitch in plane, and coarser still through plane. Standard synthetic degradations preserve subject information roughly 1 mm beyond this ceiling, so models trained and benchmarked on synthetic pairs are evaluated on information that real scanners never record. We then test trained diffusion models and a publicly released external model on real paired acquisitions; 24 trained runs of five architectures (GAN, diffusion, and transformer families) give the coverage of the audit. On every subject where faithfulness can be measured, fine output detail is no more correlated with the subject's own 3T scan than with a stranger's, while sample-variance uncertainty does not distinguish fabricated structure from reconstruction difficulty. Because PSNR and SSIM score resemblance to a reference rather than whether detail belongs to the subject, a benchmark scored by them cannot tell recovery from fabrication. Code for the measurement protocol will be released so that recoverability claims can be tested for newer models.

Figures & tables

Appendix figures & tables11 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Aug 9, 2026cs.CV

MRI super-resolution in ten sampling steps using a diffusion bridge model

Objective. MRI provides excellent soft-tissue contrast, but long acquisition times can cause patient discomfort and lead to motion artifacts, forcing a trade-off between spatial resolution and scan time. Diffusion-based super-resolution (SR) reconstructs high-resolution (HR) images from low-resolution (LR) inputs, but typically needs many sampling steps and initializes from a Gaussian prior ill-suited to image restoration. We developed an efficient diffusion framework that reconstructs HR MRI directly from LR data. Approach. We propose super-resolution diffusion bridge model (SR-DBM), a super-resolution diffusion bridge model that casts SR as a stochastic transport between the LR and HR image distributions. Through a Doob's h-transform of a mean-reverting stochastic differential equation, SR-DBM pins the process to the paired HR and LR images at its endpoints, initializing reconstruction from the measured anatomy rather than from Gaussian noise. The HR image is recovered by a deterministic reverse trajectory in which a network predicts the clean image at each of only ten sampling steps. We evaluated SR-DBM on ultra-high-field 7T brain T1 MP2RAGE maps and pelvic T2-weighted prostate images against nine comparison methods using PSNR, SSIM, GMSD, and LPIPS. Main results. SR-DBM attained the highest PSNR and SSIM and the lowest GMSD on both datasets (brain: 27.66+-1.52 dB, 0.96+-0.02, 7.96+-1.86$; prostate: 27.87+-2.29 dB, 0.80+-0.05, 8.38+- 1.44), with statistically significant gains over every comparison method (two-sided Wilcoxon signed-rank test with Holm correction, p<0.05). The strongest baseline, SR-EMamba, ranked second. Qualitatively, SR-DBM produced the smallest residual errors and best preserved fine structures and lesions.
May 23, 2026cs.CV

ULF-Synth: Physics-Guided Ultra-Low-Field MRI Enhancement for Pediatric Neuroimaging

Ultra-low-field (ULF) MRI offers portable and accessible neuroimaging but suffers from reduced signal-to-noise ratio and limited spatial resolution compared to high-field (HF) systems. Acquiring paired ULF-HF data for supervised enhancement is often difficult, particularly in resource-limited settings. We introduce ULF-Synth, a framework that combines: (i) acquisition-based synthesis of realistic ULF images from HF volumes to create large-scale paired training data, (ii) a spatial-frequency domain objective that prioritizes recovery of high-frequency anatomical detail. This formulation is architecture-agnostic, consistently improving structural similarity and perceptual fidelity across encoder-decoder, adversarial, and diffusion-based translation models. When trained exclusively on synthetic data, the resulting models generalize effectively to real 64mT ULF acquisitions, improving downstream multiclass brain segmentation and achieving higher radiologist preference and diagnostic acceptability in a blinded reader study. These findings demonstrate that synthetic paired supervision provides a practical and scalable pathway for enhancing ULF MRI without requiring real paired acquisitions. Code, Models and Dataset: https://github.com/toufiqmusah/ULF-Synth
May 29, 2026eess.IV

A physics-informed foundation model for quantitative diffusion MRI

Understanding the human brain requires access to its microscopic tissue architecture. Diffusion magnetic resonance imaging (MRI) provides the only noninvasive window into whole-brain microstructure in vivo, yet reliable quantitative mapping remains confined to specialized research settings requiring dense sampling and optimized acquisition protocols. To address this gap, we present a physics-informed generative microstructure network (PIGMENT) that learns a universal generative prior of human brain microstructure and adapts it zero-shot to each participant's measured data to recover subject-specific maps. Trained on 11375 scans spanning multiple sites, vendors, and field strengths, PIGMENT enabled reliable quantitative mapping for tensor, kurtosis, and NODDI models across external datasets from five independent centers. It remains effective where conventional fitting becomes unreliable, recovering meaningful maps from extremely sparse acquisitions while supporting downstream tractography and structural connectivity mapping. PIGMENT estimates demonstrated strong biological validity, preserving submillimeter cortical microarchitectural patterns and early-childhood white matter developmental trajectories from 10-fold accelerated scans. Furthermore, PIGMENT enables reliable quantitative tensor mapping on cost-efficient low-field systems and the extraction of tumor-related biomarkers using ultra-fast clinical protocols. Together, these results establish PIGMENT as a physics-informed foundation model that extends quantitative diffusion MRI into regimes traditionally too sparse, heterogeneous, or clinically constrained for reliable analysis.