eess.IVOct 1, 2026

Image-Based Breast Implant Detection for Mammography Dataset Curation and Near-Real-Time Deployment: Comparing Foundation Models and Task-Specific Convolutional Models

Authors: Vasisht Ishwar, Hari Trivedi, Young Seok Jeon, Beatrice Brown-Mulry, Frank Li, Rohan Satya Isaac, Mohammadreza Chavoshi, Judy Wawira Gichoya

Organizations: Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA · University of Maryland, College Park, MD, USA

Abstract

Purpose: To evaluate the performance-feasibility tradeoffs of foundation models (FMs) and task-specific convolutional neural networks (CNNs) trained from scratch for breast implant classification in 2D mammography, with emphasis on suitability for near real-time clinical deployment. Methods: We evaluated four models: two FMs (RAD-DINO and MammoCLIP) and two CNNs trained from scratch for implant prediction (ResNet18 and our lightweight ResNetLite). Using the Emory Breast Imaging Dataset, 5,000 unilateral screening mammograms were used for training/validation and 1,000 manually reviewed unilateral images were held out for testing. For the FMs, global image embeddings from the pretrained encoder were classified using a support vector machine (SVM). The CNNs were trained end-to-end on 2D mammograms, with ResNetLite optimized via grid search over depth and width to balance accuracy and efficiency. Performance was evaluated using AUROC, sensitivity, specificity, accuracy, embedding visualization, and inference-latency. Results: All models demonstrated strong performance on held-out test data (n = 1,000). MammoCLIP achieved the highest AUROC (0.999) with the quickest training time of 493 seconds. RAD-DINO achieved the highest sensitivity (0.980; accuracy 0.989) but had the slowest inference and training times. ResNet18 and MammoCLIP achieved comparable accuracy (0.985). ResNetLite showed no statistically significant difference from ResNet18 (AUROC 0.993; accuracy 0.976) despite using only 1.4% of ResNet18's parameters, and had the fastest inference time. Conclusion: FMs and task-specific CNN models reliably detect breast implants on 2D mammography. Model selection is best guided by deployment context: MammoCLIP for GPU-equipped hospital settings requiring scalable integration, and lightweight CNNs such as ResNetLite for resource-constrained or edge deployments.

Figures & tables

Explore similar work

Jun 30, 2026cs.CV

AEGIS: A Multi-Task Joint-Embedding Predictive Architecture for Mammography

We present Aegis, a joint-embedding predictive architecture for breast cancer detection and density assessment in mammography. We train three Vision Transformer variants (Small/Base/Large) using self-supervised joint-embedding predictive architecture (JEPA) pre-training on 71,103 studies from 14 clinical sites, followed by supervised fine-tuning with progressive resolution scaling up to 2048x1536. On a curated 785-study test set, our largest model achieves area under the receiver operating characteristic curve (AUC) 0.949 for breast cancer triage with 93% sensitivity and 75% specificity at the optimal operating point. An ensemble combining our model with a U.S. Food and Drug Administration-cleared baseline further improves discrimination to 0.952 AUC. For breast density classification, the model achieves 0.953 AUC for binary (dense vs. non-dense) classification and 62.6% exact accuracy across four Breast Imaging Reporting and Data System (BI-RADS) categories, with 98.8% adjacent accuracy comparable to reported human inter-reader agreement. External validation on the public VinDr-Mammo dataset provides evidence of cross-population transfer under a different reference standard, with the largest model achieving 0.871 AUC for triage in a zero-shot setting.
Aug 10, 2026cs.CV

Modern Backbones Improve Multi-task DETR for Mammography Classification and Lesion Localization

Joint exam-level prediction and candidate-region localization may improve the usefulness of AI support in mammography. We study this setting using a multi-task DETR framework, where shared representations support both image-level malignancy prediction and lesion localization, and evaluate its performance on OPTIMAM and a biopsy-confirmed SGM1k cohort. Across both datasets, modern backbones consistently outperformed older ResNet-style features, with ConvNeXtV2 and DINOv3 giving the strongest overall results, whereas MambaVision was less competitive. On OPTIMAM, ConvNeXtV2 achieved the best overall performance, reaching 97.96% AUC, 99.89% sensitivity, 25.08% [email protected], and 74.38% [email protected]. On SGM1k, DINOv3 gave the strongest overall results, with 90.97% AUC, 86.28% sensitivity, 82.00% specificity, 27.04% [email protected], and 77.32% [email protected]. These findings suggest that backbone quality is a critical factor in effective multi-task mammography, with ConvNeXtV2 emerging as a particularly strong and well-matched CNN backbone for mammography in this framework.
Sep 22, 2026cs.CV

Foundation model embeddings capture pre-diagnostic changes on screening mammograms

Foundation model embeddings of screening mammograms may encode pre-diagnostic tissue change without task-specific adaptation. We tested whether embeddings move faster along a data-derived "cancer direction" in women later biopsied for cancer than in matched screen-negative controls, and whether this depends on pretraining domain. We studied 1,773 biopsied women (785 malignant, 988 biopsy-negative) and 1,773 matched controls, each with at least two annual screening exams before their index exam. An identical pipeline was applied to four 2D models: Mammo-CLIP (MC, out-of-distribution mammography), HOPPR (in-distribution mammography), MedImageInsight (MII, general medical imaging), and BiomedCLIP (biomedical vision-language pretraining on literature figures). Breast-level embeddings quantified longitudinal movement along the cancer direction. We compared cases and controls using a between-patient design with complementary mixed-effects analysis, and biopsied versus healthy contralateral breasts within patients. Under matched modality in MII embedding space, malignant cases drifted significantly faster than controls in the first two screening intervals preceding the index exam; biopsy-negative cases showed significance only in the first. MC differences were significant in the first interval for both biopsy groups. Within-patient comparisons showed a broadly similar pattern, with MC significance extending to the second interval in both groups and HOPPR showing significance at interval 1. BiomedCLIP showed no significant differences in either design or biopsy group. Overall, directional embedding velocity emerges as a property of clinically grounded rather than general biomedical pretraining, showing that foundation model embeddings can encode pre-diagnostic mammographic change without task-specific adaptation.