cs.ROOct 2, 2026

Sparse Calibration-Based Personalization of Kernel-Based Gait Phase and Speed Estimation Using Wearable IMUs

Authors: Myeongju Cha, Pilwon Hur

Organizations: Department of Mechanical and Robotics Engineering, GIST, Gwangju, Korea

Abstract

This paper presents sparse calibration-based personalization for kernel-based gait phase and walking speed co-estimation from wearable inertial measurement units (IMUs). A 28-speed reference library was constructed from bilateral thigh and shank trajectories in a 20-subject locomotion dataset. Rather than directly applying population-average kernels, the method combines a user-specific baseline estimated from three calibration speeds with a principal-component (PC) model of baseline-centered kinematic deviations. Offline validation showed that personalized kernels reduced phase error relative to the population kernel. In a single-participant online pilot evaluation, the personalized kernels produced numerically lower mean phase and speed errors and ran in real time on embedded hardware. However, the speed effect was not significant, and pairwise phase differences did not remain significant after multiple-comparison correction. The pilot evaluation establishes wearable implementation feasibility while indicating reference-to-online dataset mismatch and the need for larger-cohort validation.

Figures & tables

Explore similar work

Oct 13, 2026

Tread: A Visuo-Inertial Framework for Terrain and Locomotion Context-Aware Gait-Phase and Speed Estimation in Wearable Robotics

A wearable assistive robot must continuously estimate terrain, locomotion mode, gait phase, and walking speed. These quantities are commonly addressed by separate, terrain-specific models, with datasets rarely collected under a common protocol. This paper presents a visuo-inertial framework that connects these estimates through a causal pipeline using a chest-mounted camera and four lower-limb inertial measurement units (IMUs). Anticipatory Terrain Perception (ATP) classifies incoming terrain with 96.3% accuracy and anticipates terrain transitions by 1.46 s on average. Terrain-Aware Locomotion Mode Identification (TALMI) achieves 93.7% and 98.8% accuracy for its level-ground and stairs experts respectively, with mean transition latencies being below 200 ms. The relevant TALMI posterior is retained as a Probabilistic Locomotion Context (PLC) vector and provided to a shared Gait Kinematic Encoder (GKE), which supports 50-Hz bilateral gait-phase estimation and 2-Hz walking-speed estimation. Leave-one-subject-out evaluation yields gait-phase RMSEs of 1.75%, 2.97%, and 4.55% for level walking, stair ascent, and stair descent respectively while estimating speed over 3.5-5.5 km/h with a RMSE of 0.218 km/h. All inertial sensing based models use sensor-fused Euler angles as input rather than raw accelerometer and gyroscope signals, reducing dependence on sensor mounting variation.
Sep 14, 2026

Two-Stage Personalized Gait Phase Estimation in Stroke Survivors During Exoskeleton-Assisted Walking: An Offline Feasibility Study

This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided reference phase labels for offline adaptation and evaluation. Stage 1 established a distillation-regularized participant-specific model, and Stage 2 performed conditional refinement using low-rank adaptation. Long Short-Term Memory (LSTM), Temporal Convolutional Network (TCN), and Transformer models were evaluated in five stroke survivors walking with a powered knee exoskeleton using leave-one-subject-out hyperparameter selection and sequential test-then-adapt Stage 2 replay. Relative to the non-adapted baselines, Stage 1+2 reduced the mean participant-wise phase root mean square error by 84.2%, 77.0%, and 60.7%, respectively. The Transformer achieved the lowest final error (2.90 +- 1.13$% of the gait cycle) and heel-strike timing error (23.7 +- 4.5ms). Policy-specific ablations showed that every-cycle updates generally produced the lowest or near-lowest error, whereas conditional updating reduced the update frequency with small accuracy differences. After personalization, alignment produced model-dependent changes in phase error while preserving or improving heel-strike detection and reducing heel-strike timing error for the LSTM and Transformer. Concurrent embedded tests showed that the TCN and Transformer maintained 100-Hz inference during Stage 2 updates without deadline misses, whereas the LSTM missed the 10-ms deadline in 6.6% of inferences. All updates completed within 0.8s. These results support the offline feasibility and embedded computational timing of the proposed framework for exoskeleton-assisted walking.
Jul 8, 2026

Generating Personalized Lower-Limb Kinematics Across Walking Speeds Using Subject-Conditioned Diffusion

Personalizing exoskeleton assistance requires user-specific gait data across many locomotor tasks, yet collecting this data demands repeated motion capture sessions that are costly, time-intensive, and especially burdensome for clinical populations. This challenge is most acute across walking speeds, where gait changes substantially and deviates further in clinical gait. This work introduces a subject-conditioned residual diffusion framework that generates personalized lower-limb kinematics at unseen walking speeds from a subject's gait sequence at a single seen speed. Given sagittal-plane hip, knee, and ankle trajectories at a seen speed and a desired unseen speed, the model generates a residual that transforms the seen trajectory into the unseen one, using a transformer denoiser conditioned on the subject's gait and the two speeds through feature-wise linear modulation. Trained only on able-bodied data, the model achieved a mean absolute error (MAE) of 3.4° on held-out able-bodied subjects. Without any stroke-specific fine-tuning, it achieved a 6.0° MAE on out-of-training-distribution stroke subjects, retaining subject identity for clinical gait. The framework reduced the MAE by over 70% relative to supervised feed-forward baselines, and a single seen speed matched the accuracy of four speeds within 0.4°. These results demonstrate that subject-conditioned residual diffusion can synthesize personalized gait across speeds from minimal data, reducing the collection burden for downstream exoskeleton personalization.