Abstract

Wearable electrocardiogram (ECG) recordings pass through multiple networks and systems before automated interpretation, making patient metadata vulnerable to loss. Digital watermarking embeds this metadata directly into the signal. However, conventional ECG watermarking methods fail under temporal desynchronization, and waveform similarity does not guarantee downstream diagnostic preservation. This article presents ECGWmark, a deep watermarking framework for single-lead ECG. A fully convolutional generator embeds the payload without signal quantization, a detector decodes the message frame by frame and verifies watermark presence, and a frozen arrhythmia classifier penalizes changes that would alter diagnostic predictions. To bridge the gap between bit accuracy and whole-message recovery, payloads are protected by extended Hamming codes, validation-selected interleaving, and soft-decision decoding. On the MIT-BIH Arrhythmia Database, ECGWmark maintains over 90% bit accuracy under time shifts of 10 to 50 samples, where transform baselines fall to chance level. With the coding layer, the protected 16-bit payload achieves 99.86% exact recovery on clean segments and sustains over 90% recovery under time shifts, 10% sample deletion, and 10% packet loss. Inter-patient evaluation confirms improved ventricular-beat sensitivity with preserved macro-F1. Requiring only 0.56 million parameters and about 15~ms per segment on a desktop CPU, ECGWmark highlights the need to assess physiological watermarking through whole-message recovery and diagnostic consistency.

Figures & tables

Explore similar work

May 26, 2026

Information-theoretic Multimodal Representation Learning for Electrocardiogram Signals

Electrocardiograms (ECGs) are widely used non-invasive measurements of cardiac activity and play a central role in clinical diagnosis. Recent multimodal approaches align ECG signals with clinical reports to incorporate diagnostic semantics, but clinical reports often fail to preserve the rich physiological structure of ECG waveforms, particularly across multiple levels of abstraction ranging from coarse diagnostic categories to fine-grained morphology. To address this limitation, we formulate ECG representation learning from an information-theoretic perspective and derive a tractable objective that jointly preserves signal structure and integrates clinical semantics. Based on this principle, we propose MERIT (Multimodal ECG Representation via Information Theory), a dual-branch pretraining framework combining masked ECG modeling with ECG--text contrastive alignment. Extensive experiments on PTB-XL and additional benchmarks demonstrate consistent improvements over prior methods, including gains exceeding 33% F1 on PTB-XL All and 55% F1 on SubClass classification. In zero-shot evaluation, MERIT further improves performance by up to +2.66% +2.66\% AUC and +2.11% +2.11\% F1 on PTB-XL SubClass, while also demonstrating robustness under multiple distribution-shift settings. Moreover, leveraging the learned ECG representations for ECG-conditioned clinical text generation with large language models improves text quality across several metrics, including ROUGE and METEOR. Together, these results demonstrate that MERIT learns more informative and clinically meaningful ECG representations, particularly for fine-grained clinical applications.
Feb 24, 2026

CG-DMER: Hybrid Contrastive-Generative Framework for Disentangled Multimodal ECG Representation Learning

Accurate interpretation of electrocardiogram (ECG) signals is crucial for diagnosing cardiovascular diseases. Recent multimodal approaches that integrate ECGs with accompanying clinical reports show strong potential, but they still face two main concerns from a modality perspective: (1) intra-modality: existing models process ECGs in a lead-agnostic manner, overlooking spatial-temporal dependencies across leads, which restricts their effectiveness in modeling fine-grained diagnostic patterns; (2) inter-modality: existing methods directly align ECG signals with clinical reports, introducing modality-specific biases due to the free-text nature of the reports. In light of these two issues, we propose CG-DMER, a contrastive-generative framework for disentangled multimodal ECG representation learning, powered by two key designs: (1) Spatial-temporal masked modeling is designed to better capture fine-grained temporal dynamics and inter-lead spatial dependencies by applying masking across both spatial and temporal dimensions and reconstructing the missing information. (2) A representation disentanglement and alignment strategy is designed to mitigate unnecessary noise and modality-specific biases by introducing modality-specific and modality-shared encoders, ensuring a clearer separation between modality-invariant and modality-specific representations. Experiments on three public datasets demonstrate that CG-DMER achieves state-of-the-art performance across diverse downstream tasks.
Sep 18, 2026

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.