cs.AISep 18, 2026

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

Authors: Luca Thiebaud, Paul Chauchat, Mustapha Ouladsine, Stéphane Delliaux

Organizations: AMU, AMU SCI, DIAPRO, LIS · Aix-Marseille Univ, CNRS, LIS, Marseille, France · AMU SCI, AMU, LIS, DIAPRO · AMU, APHM, C2VN · 

Abstract

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.

Explore similar work

May 2, 2026

ECG-biometrics-bench: A Unified Framework for Reproducible Benchmarking of ECG Biometrics

Electrocardiogram (ECG) biometrics have emerged as a promising modality for continuous, liveness-aware authentication in wearable systems. However, many prior studies report overly optimistic results due to data leakage (e.g., random splits within the same session). To address this issue, we introduce ECG-biometrics-bench, a modular, reproducible benchmarking framework that standardizes preprocessing, segmentation, and evaluation across seven widely used public ECG datasets spanning clinical, ambulatory, and large-scale cohort settings. The framework supports both closed-set and open-set (i.e., subject-disjoint generalization in this work) evaluation, as well as progressively realistic protocols including cross-session and long-term temporal separation. To facilitate reproducible research in the community, the ECG-biometrics-bench repository will be made publicly accessible on GitHub upon the acceptance of this manuscript. Through a comprehensive multi-dataset analysis, we expose the Random Split Fallacy, demonstrating that intra-session evaluation protocols artificially inflate performance while masking severe degradation caused by temporal drift and unseen identities. Furthermore, by evaluating multiple architectures, including DeepECG, ResNet1D, and CNN-LSTM, we show that these failures are not model-specific but are likely inherent to current supervised feature-learning paradigms. Finally, we demonstrate that performance degradation due to temporal aging can be partially mitigated through a heavy enrollment, lightweight authentication strategy based on dynamic multi-session template fusion. These findings establish a more realistic baseline for ECG biometrics and highlight critical challenges that must be addressed for reliable real-world deployment.
May 17, 2026

Attention-Guided Fusion of 1D and 2D CNNs for Robust ECG-Based Biometric Recognition

Electrocardiogram (ECG)-based biometric recognition has emerged as a promising solution for secure authentication and liveness detection. However, most existing methods rely on unimodal deep learning architectures that independently process either one-dimensional (1D) temporal signals or two-dimensional (2D) time-frequency representations, limiting robustness and generalization. To address this issue, this paper proposes a hybrid framework integrating 1D and 2D convolutional neural networks (CNNs) within a unified end-to-end architecture. The 1D branch extracts temporal and morphological features from raw ECG signals, while the 2D branch captures discriminative spectral information from time-frequency representations. An attention-guided fusion mechanism dynamically weights both modalities according to input characteristics, overcoming the limitations of conventional static fusion strategies. The framework was evaluated on three benchmark datasets (ECG-ID, MIT-BIH, and PTB), including healthy subjects and patients with cardiac pathologies, achieving identification accuracies of 99.56%, 100.00%, and 99.89%, respectively. To assess long-term biometric permanence, experiments were also conducted on the multi-session Heartprint dataset spanning ten years. The proposed approach achieved same-session accuracies of 98.54% (S1), 99.09% (S2), 94.93% (S3R), and 96.08% (S3L), while cross-session evaluations reached 56.33% (S1-S2) and 53.27% (S2-S3R), demonstrating the ability to capture stable biometric signatures over time. The optimal configuration combines InceptionTime for 1D processing, ResNet-34 for 2D analysis, and attention-based fusion. Ablation studies confirm that the proposed attention mechanism consistently outperforms conventional fusion approaches. Overall, the proposed framework provides a robust, scalable, and high-performance solution for ECG biometric recognition.
Apr 6, 2026

ECG Biometrics with ArcFace-Inception: External Validation on MIMIC and HEEDB

ECG biometrics has been studied mainly on small cohorts and short inter-session intervals, leaving open how identification behaves under large galleries, external domain shift, and multi-year temporal gaps. We evaluated a 1D Inception-v1 model trained with ArcFace on an internal clinical corpus of 164,440 12-lead ECGs from 53,079 patients and tested it on larger cohorts derived from MIMIC-IV-ECG and HEEDB. The study used a unified closed-set leave-one-out protocol with Rank@K and TAR@FAR metrics, together with scale, temporal-stress, reranking, and confidence analyses. Under general comparability, the system achieved Rank@1 of 0.9506 on ASUGI-DB, 0.8291 on MIMIC-GC, and 0.6884 on HEEDB-GC. In the temporal stress test at constant gallery size, Rank@1 declined from 0.7853 to 0.6433 on MIMIC and from 0.6864 to 0.5560 on HEEDB from 1 to 5 years. Scale analysis on HEEDB showed monotonic degradation as gallery size increased and recovery as more examinations per patient became available. On HEEDB-RR, post-hoc reranking further improved retrieval, with AS-norm reaching Rank@1 = 0.8005 from a 0.7765 baseline. ECG identity information therefore remains measurable under externally validated large-scale closed-set conditions, but its operational quality is strongly affected by domain heterogeneity, longitudinal drift, gallery size, and second-stage score processing.