RePrior: Measurement-Reconciled Prior Correction for Sparse-View CBCT Reconstruction

Authors: Mengrui Yin, Tianxingjian Ding, Wufan Zhao, Ziyang Yan, Yu Tian

Organizations: University of Central Florida · The Hong Kong University of Science and Technology (Guangzhou) · Tampere University · Ellis Institute Finland

Abstract

Sparse-view cone-beam computed tomography (CBCT) is severely under-constrained by limited X-ray projections. Learned reconstruction can provide complementary anatomical information, but using it as a prior in patient-specific Gaussian reconstruction introduces two challenges. First, the discrepancy between the learned prior and current reconstruction is spatially non-uniform: some local differences contain useful missing 3D information, whereas others reflect prior bias. Second, even a volumetrically beneficial correction can conflict with the observed X-ray measurements. Since X-ray measurements are line integrals, spatially separated corrections may affect overlapping rays, with their signed projection responses reinforcing or partially canceling in the measurement residual, so their feasibility cannot always be assessed independently. In this paper, we introduce RePrior, a multi-stage progressive prior-correction framework that addresses correction actionability, measurement feasibility, and representation expressivity. Selective Correction Proposal (SCP) first identifies actionable signed local corrections from prior--reconstruction discrepancies. Measurement-Constrained Reconciliation (MCR) then jointly enforces their consistency with patient-specific X-ray measurements, while Hybrid Residual Enhancement (HRE) recovers additional correction capacity through complementary voxel- and Gaussian-domain degrees of freedom around the reconciled anchor. RePrior requires neither test-time ground truth nor case-specific network fine-tuning. RePrior gains approximately 2.6~dB in 3D PSNR over R2^2-Gaussian across LUNA16, PANORAMA, and PENGWIN. Beyond prior-assisted reconstruction, it delivers additional gains in volumetric quality and observed-view projection fidelity, with consistent gains in held-out-view fidelity in the backbone-matched evaluation.

Figures & tables

Appendix figures & tables8 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

CardsList
  1. AD-GS: Anatomical Density-guided 3D Gaussian Splatting for Sparse-View Dental CBCT Reconstruction

    Oct 10, 2026Zonglin Li, Kexian Xie, Feiran Li +5Sparse-View CT Reconstruction3D Gaussian Splatting

  2. ILV: Iterative Latent Volumes for Fast and Accurate Sparse-View CT Reconstruction

    Mar 16, 2026Seungryong Lee, Woojeong Baek, Joosang Lee +1Cone-Beam CTImage Reconstruction