cs.AIOct 17, 2026

MedPAO-Assist: Edge-Deployable, Modality-Aware Agentic AI for Radiology Report Structuring

Authors: Shrish Shrinath Vaidya, Minmini Selvam, Ganapathy Krishnamurthi

Organizations: Department of Data Science and Artificial Intelligence, Indian Institute of Technology Madras, Chennai, India · TANUH – The AI Centre of Excellence in Healthcare, Indian Institute of Science, Bengaluru, India

Abstract

The adoption of Large Language Models for radiology report structuring has been largely dominated by either proprietary cloud-based models or large open models requiring high-end GPUs for deployment, which is a critical bottleneck for clinical adoption in radiology workflows that demand data privacy and offline operation. To address this, we present MedPAO-Assist, an edge-deployable agentic framework that generates structured radiology reports directly from radiologist dictation and voice commands, requiring only ≈3.3\approx3.3 GB peak RAM and achieving an average end-to-end latency of ≈31\approx31 seconds on a standard laptop CPU through an asynchronous, multi-threaded execution pipeline. The system currently supports four major imaging modalities -- Chest X-ray, Chest CT, Abdomen CT, and Brain MRI. To our knowledge, it is among the earliest agentic systems to run its entire pipeline with a Small Language Model (SLM) in the 0.6B-parameter range. This multi-agent architecture, built around an Extract-Ground-Generate paradigm, performs concept extraction, SNOMED-CT grounding, and structured report generation, followed by a speech-driven human-in-the-loop correction phase, together forming a fully "no-touch" reporting workflow that requires no keyboard input, external API calls, or internet connectivity. We evaluate each pipeline stage individually -- concept extraction, ontology grounding, and concept categorization and report hardware profiling results demonstrating the system's feasibility for real-time, CPU-only clinical deployment.

Figures & tables

Explore similar work

Oct 15, 2026

MedPAO-VL: Interpretable and Protocol-Compliant Agent for Structured Radiology Report Generation

Despite the remarkable generalization capabilities of Large Language Models, generating clinically accurate and structured radiology reports from medical images remains a significant challenge. Current end-to-end approaches function as black boxes, prone to factual hallucinations and generating ungrounded findings. This lack of reliability and failure to adhere to domain-specific structuring protocols, fundamentally limits their clinical utility. We present MedPAO-VL, a multimodal agent that shifts the paradigm from monolithic generation to explainable, iterative, protocol-compliant structured report generation. Unlike deterministic models, our plan-act-observe loop functions as a goal-oriented agent: it first perceives the Chest X-Ray through an explainable vision module designed to capture inherent diagnostic uncertainty, then iteratively refines the generated report by observing semantic discrepancies and self-correcting its generation for better alignment with visually detected clinical findings. Evaluation of our framework demonstrates that this agentic reasoning improves clinical correctness and completeness, achieving an expert-rated accuracy score of 3.5/5 and a structural score of 4.3/5. By prioritizing pathology specific explainability and iterative refinement over opaque end-to-end mapping, MedPAO-VL offers a transparent and clinically viable alternative for automated structured radiology report generation.
Mar 14, 2026

EviAgent: Evidence-Driven Agent for Radiology Report Generation

Automated radiology report generation holds immense potential to alleviate the heavy workload of radiologists. Despite the formidable vision-language capabilities of recent Multimodal Large Language Models (MLLMs), their clinical deployment is severely constrained by inherent limitations: their "black-box" decision-making renders the generated reports untraceable due to the lack of explicit visual evidence to support the diagnosis, and they struggle to access external domain knowledge. To address these challenges, we propose the Evidence-driven Radiology Report Generation Agent (EviAgent). Unlike opaque end-to-end paradigms, EviAgent coordinates a transparent reasoning trajectory by breaking down the complex generation process into granular operational units. We integrate multi-dimensional visual experts and retrieval mechanisms as external support modules, endowing the system with explicit visual evidence and high-quality clinical priors. Extensive experiments on MIMIC-CXR, CheXpert Plus, and IU-Xray datasets demonstrate that EviAgent outperforms both large-scale generalist models and specialized medical models, providing a robust and trustworthy solution for automated radiology report generation.
Jul 7, 2026

Harrison.Rad 1.5 Technical Report: A radiology foundation model that can draft reports from images, priors and clinical context

Imaging demand is growing faster than the radiology workforce can expand, and reporting backlogs cannot be resolved through training and recruitment alone. The most direct opportunity is reducing the time and effort radiologists spend producing reports, a task that requires interpreting images, integrating clinical history and prior studies, and drafting structured findings. We present Harrison.Rad 1.5 (HR1.5), a radiology-specific multimodal large language model that accepts interleaved text and visual inputs and generates structured and unstructured text across plain-film radiology, spanning computed radiography, chest, musculoskeletal, abdominal, spine, and pelvic x-rays, and mammography. HR1.5 is trained through a three-stage pipeline: domain adaptation of a base language model on radiology reports, contrastive vision-encoder training with curriculum-based hard negatives on ~6 million image-report instances, and visual-question-answering fine-tuning on multi-turn conversations. We evaluate it with a Findings-Diagnosis scoring framework that extends RadGraph-XL entity extraction with ontology-based synonym matching and polarity-contradiction detection, benchmarked on RadBench, a simulated FRCR 2B Short Case examination scored against Angoff-method thresholds, ReXGradient, and internal multi-modality datasets. HR1.5 is the only system evaluated to meet the simulated FRCR passing standard and achieves the highest accuracy on closed-format clinical questions, across anatomical regions, on internal multi-body-part and mammography reporting, and on the primary clinically-aligned score for public chest reporting. We further examine explainability and model behaviour, including question-sensitive Grad-CAM heatmaps, attention analysis, and confidence estimation, to support responsible future evaluation toward clinical use, and a framework for clinically grounded assessment of report quality.