LLM correctors of ASR output are judged by aggregate WER, which hides what they fix and what they break. We decompose every WER change exactly into repaired tokens, damaged tokens and insertions, and use this to ask what the source audio adds to a corrector. We compare correction with and without the audio, for the model's own draft and for the output of an independent recogniser, on three corpora. With Gemini 2.5 Flash, text-only correction of its own draft breaks 13-32% of already-correct transcripts; with the audio, 1-3%. Damage falls in both settings. Repair falls against the own draft and rises against the recogniser. On medical dictation, kept insertions cancel the gain in net WER. The open-weight Voxtral, which rarely edits, does not show this pattern. Prompts differ between the two arms, so the contrasts bound the effect of the audio and do not isolate it.
Figures & tables
TTS RU
RuLibri RU
Medical EN
n=2,260
n=270
n=284
input systems (WER, %)
ASR output (recogniser)
3.95
7.29
16.06
Draft (audio LLM)
2.39
10.04
17.65
control, against the draft ( Δ WER, pt)
B audio, no hypothesis
+ 0.01
+ 0.18
+ 2.53
Table 1: Gemini 2.5 Flash. Top: WER (%) of the two input systems. Below: ΔWER (pt) of each cell against the system that supplied its input; positive is an improvement. Bold: 95% interval excludes zero.
rep
dam
ins
net
break-rate
self-correction: A (audio) vs. C (no audio)
TTS RU
− 0.15
− 2.83
+ 0.24
+ 2.92
31.9 → 2.6
RuLibri RU
− 0.50
− 0.88
+ 0.08
+ 0.45
16.3 → 1.0
Medical EN
− 0.74
− 1.72
− 1.08
− 0.09
12.8 → 2.3
cross-system: F (audio) vs. T (no audio)
TTS RU
+ 0.09
− 1.31
+ 0.08
+ 1.48
18.1 → 2.6
Table 2: Effect of the audio, Gemini 2.5 Flash: grounded minus text-only cell, pt; net = rep − dam + ins. Negative dam: less damage; positive ins: fewer insertions left. Bold: 95% interval excludes zero. Break-rates (%, text-only → grounded) have no intervals.
#
Reference
Input hypothesis
Output without audio
Output with audio
1
loss of hair
loss of hair
loss of hearing
loss of hair
2
postoperative imaging …
post operative imaging …
postoperative imaging …
post operative imaging …
3
forxiga 10mg tablet
forxa 10 mg tablet
forxiga 10 mg tablet
forxa 10 mg tablet
4
seizure
see you soon
see you soon
seizure
5
oxiconazole
oxyconosol
oxycontin
oxiconazole
Table 3: Illustrative examples from the medical corpus (Gemini 2.5 Flash, normalized text); italics mark tokens changed by the corrector. Rows 1–3: self-correction, the input is the draft; row 2 shows the first tokens of a 32-token utterance. Rows 4–5: cross-system, the input is the Whisper output.
ASR
T
F
draft
C
A
B
WER
3.79
3.26
1.74
2.37
5.12
2.18
2.75
CER
0.79
1.23
0.42
0.67
2.57
0.67
1.18
DTR
65.5
67.5
69.7
69.0
66.1
69.3
69.1
WER, original
–
–
–
–
5.03
2.19
2.76
WER, 15 dB
–
–
–
–
6.16
3.20
4.05
WER, 8 dB
–
–
–
–
8.91
6.02
7.45
Table 4: Synthetic corpus, Gemini 2.5 Flash, raw rates in % (WER and CER: lower is better; not Δ WER). Top: each system over its own complete outputs ( n=2,262 – 3,000 ); columns cover different utterance sets and are not paired. Bottom: WER on 250 clips, original and with reverberation and noise. No intervals are available.
TTS RU
RuLibri RU
Medical EN
n=467
n=96
n=96
input systems (WER, %)
ASR output (recogniser)
5.17
8.02
17.03
Draft (audio LLM)
7.90
26.31
43.86
cells ( Δ WER, pt)
B audio, no hypothesis
− 1.61
+ 6.09
− 21.15
Table 5: Voxtral-Small-24B on subsets of the same clips; layout and units as in Tables 1 and 2 . The ins rows are obtained by subtraction and have no intervals. Bold: 95% interval excludes zero.
Idiap Research Institute, Martigny, Switzerland · KTH Royal Institute of Technology, Stockholm, Sweden · Brno University of Technology, Brno, Czech Republic
†Institute of Advanced Intelligence and Computing, Agency for Science, Technology and Research, Singapore · ⋆Nanyang Technological University, Singapore