Cyber-physical attack detection approaches in the wide-area measurement system

Authors: Zakaria El Mrabet, Prakash Ranganathan

Organizations: University of North Dakota, Grand Forks, ND, USA

Abstract

Improving situational awareness within the Smart Grid is an effective preventive measure to detect potential anomalies, and avoid their adverse consequences. A wide area measurement system (WAMS) based Phasor Measurement Unit (PMU) can assist in improving visibility within the grid by collecting relevant measurements including magnitude, phase angle, frequency, voltage, and current, with a precise GPS-based timestamp. So far, there are more than 2500 PMUs deployed in the North American power grid, where each of which generates between 30 and 60 samples/s, roughly 1.5 TB/month of streamed data. Thus, processing such large PMU streams requires expensive computational resources and faster algorithms. This paper provides state-of-the-art cyber and physical anomalies in the WAMS and analyses their impact on the integrity and availability of the system. Next, it investigates the current anomaly detection approach in historical and streaming PMU data, including conventional machine learning and hybrid approaches, and assesses their advantages and main drawbacks. Lastly, it sheds light on the importance of handling missing PMU data and concept drifts.

Explore similar work

May 21, 2026

Cyber-Physical Anomaly Detection in IoT-Enabled Smart Grids Using Machine Learning and Metaheuristic Feature Optimization

Modern smart grids rely on dense measurement infrastructures, communication links, and intelligent field devices. Although this improves supervision and control, it also increases vulnerability to cyber-physical disruptions. Operators must distinguish physical incidents, such as faults or line disturbances, from malicious actions, such as false data injection or unauthorized command execution. This chapter investigates this problem using the well-known MSU/ORNL Power System Attack Dataset. The proposed method combines machine learning with genetic-algorithm-based feature selection. The objective is twofold: to classify attack and natural events accurately, and to determine whether a reduced set of physically informative PMU/IED measurements can support reliable detection. Several baseline models are evaluated, including logistic regression, RBF-SVM, XGBoost, Random Forest, and Extra Trees. The results show that tree-based ensemble models are the most effective for the considered dataset, with Extra Trees providing the strongest full-feature baseline. After feature selection, the GA + Extra Trees model reduces the clean PMU feature space from 112 attributes to an average of 27.4 attributes over five runs, while increasing macro-F1 from 0.9118 to 0.9212 and ROC-AUC from 0.9791 to 0.9837. These results indicate that many synchronized electrical measurements are redundant. A compact subset of phasor-based features can still provide accurate and interpretable anomaly detection in smart grids.
Nov 7, 2026

Interpretable Cyber-Physical Attack Detection in Smart Grids: A Leakage-Controlled Multi-Testbed Evaluation of Fusion, Robustness, and Observability Limits

Cyber-physical smart-grid detectors are typically treated as black boxes and validated exclusively on clean, temporally shuffled datasets, which risk overly optimistic performance claims. This work presents a multi-testbed evaluation study built around an interpretable, time-windowed fusion Random Forest, adopting the pessimistic result whenever evaluation protocols disagree. (i) On a public paired cyber-physical dataset, shuffled cross-validation is optimistic: macro-F1 falls from 0.96 to 0.88 +/- 0.06 under rolling-origin temporal evaluation. A topology-free graph convolutional network (GCN) serving as a control confirms that this lightweight model is competitive on these splits. (ii) The adaptive and adaptive-joint feature-space attacks, which are infeasible as realistic grid manipulations, degrade macro-F1 to 0.67 and 0.34, respectively. Adversarial training and randomized smoothing partially restore performance, and a physics-constrained evolution-strategy evasion on the IEEE 14-Bus testbed shows the same vulnerability pattern. (iii) On real IEC-104 traffic, the cyber view reliably catches structural attacks (recall of 0.87 to 0.98) but largely fails on semantic value manipulation (recall of 0.11 to 0.35). An observability taxonomy on the IEEE 14-Bus system reveals that stealthy false data injection defeats all three observation views. (iv) On a full AC weighted least-squares state-estimation testbed, a forecasting-aided temporal test is evaded by slow ramps precisely where a rate-invariant physics-manifold test sustains detection at a common 5% false-alarm target. A full end-to-end evaluation on IEEE 118-Bus confirms the ordering but bounds its strength: the manifold test detects every trial down to 0.05 degree/step and 0.48 at 0.02 degree/step, against 0.14 for the temporal test. All code and benchmarks are released.
Jun 14, 2026

Early Anomaly-Onset Detection based on Wigner--Ville Distribution Slice Spectra: A Transmission-Grid Test Case

Operational disturbance monitoring in power networks requires decisions to be made from waveform windows as they arrive, rather than from completed records after the event. This study evaluates full-vector Wigner--Ville Distribution Slice (WVDS) spectra for sequential anomaly-onset detection in high-voltage grid-voltage waveforms. The approach keeps the bilinear midpoint interaction structure of the Wigner--Ville distribution and represents each 128-sample voltage window by a 128-dimensional slice spectrum, avoiding manually selected fault-frequency markers. WVDS is used with a baseline-normalized deviation (BND) score and is compared against the BND of Fast Fourier Transform (FFT-BND), raw-window autoencoders, FFT autoencoders, and WVDS autoencoders under the same thresholding and three-window persistence rule. A synthetic autoencoder--clustering teacher is used to select RTE fault records that start from an initially normal region and then transition to anomalous behavior. On the filtered test set, FFT-BND achieves the highest sensitivity, whereas WVDS-BND provides the lowest false-alarm operating point, reducing record-level pre-onset false alarms to 0.69%. The autoencoder comparison follows the same selectivity pattern: WVDS reconstruction decreases false alarms relative to FFT reconstruction but misses more examples. The results indicate that preserved WVD cross-term information can form a selective representation for online grid-waveform anomaly monitoring when false alarms are costly.