cs.CVNov 1, 2026

Biological Congruence: Evaluating Microscopy Generation Across Representations

Authors: Duway Nicolas Lesmes-Leon, Shumpei Takezaki, Fabian Schmeisser, Ryoma Bise, Gillian Lovell, Bianca Migliori, Andreas Dengel, Sheraz Ahmed

Organizations: German Research Center for Artificial Intelligence (DFKI), Kaiserslautern, Germany · RPTU Kaiserslautern-Landau, Kaiserslautern, Germany · Kyushu University, Fukuoka, Japan · Sartorius Corporate, Royston, UK

Abstract

Generative models increasingly produce realistic microscopy images, yet conventional evaluation primarily characterizes visual fidelity and distributional coverage rather than the biological information represented by synthetic data. We introduce biological congruence as an evaluation principle describing whether biologically relevant information forms a coherent description across representations and remains consistent with its empirical biological context. To study this principle, we develop a text-conditioned diffusion framework that jointly generates microscopy images and instance masks, exposing the same generated biological state through conditioning, visual appearance, and instance structure. Across prompt--mask, prompt--image, image--mask, and population-level analyses, we find strongly feature-dependent behavior: density and confluency are consistently preserved, morphology exhibits recurrent disagreement, while nearest-neighbor distance reveals that strong image--mask agreement can coexist with weaker conditioning and population fidelity. Stress testing increasingly unsupported phenotype combinations further shows that target controllability can increase while untargeted phenotypes reorganize and the complete generated state moves toward configurations better supported by real data. These findings demonstrate that generative quality, controllability, cross-representation agreement, and population fidelity capture complementary properties, motivating biological congruence as a relational perspective for evaluating scientific generative models.

Figures & tables

Appendix figures & tables9 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Jun 8, 2026

Assessing Sample Quality in Conditional Generation under Compositional Shift

Conditional generators provide a natural tool for controllable generation, including settings where the desired condition is a new composition of observed attributes or experimental factors. In many applications, especially in scientific domains, such models are attractive to explore conditions for which real samples are rare, expensive, or not yet observed. However, this creates a circularity for evaluation: standard conditional quality metrics require a reference target distribution, but in the extrapolative regime that distribution is unavailable by definition. We address this problem with a post-hoc, per-sample trust score for assessing conditional samples using only the training distribution. The score combines two estimable quantities: global realism, measuring compatibility with the real data manifold, and attribute-wise faithfulness, measuring whether a sample is closer to the requested attributes than to plausible alternatives. We show that the score can recover meaningful comparisons across extrapolated generations, under a mild coverage condition on the observed attributes. These comparisons enable effective filtering, ranking, and abstention of generations and can be used directly on off-the-shelf pretrained models. In biological imaging, selected samples preserve real morphological structure better and improve downstream predictive performance, while similar gains are observed on controlled vision benchmarks. Finally, we show how the score can be applied during generation, enabling abstention before full decoding. Code is available at https://github.com/berkerdemirel/faithful-cond-gen.
Oct 24, 2026

Rethinking Microscopy Generation: Co-Designed Diffusion for Biologically Interpretable Single-Cell Synthesis

Generative models for microscopy can already produce realistic whole-image fields of view, but offer no principled way to control how each individual cell looks. We address this gap by recasting microscopy generation at the single-cell level and designing the input controls and the model's internal representation jointly, so that both are organized along the same biologically meaningful directions. On the input side, we aggregate a long list of standard cell measurements into a small set of semantic axes (size, elongation, brightness, texture, etc.) that are each named, measurable, and traversable. On the model side, we introduce BioVAE, an encoder-decoder whose latent space is explicitly aligned with the same set of measurements. A key finding is that the benefit of biologically structuring the latent emerges only when conditioning is also moved to the semantic axes, showing that the two ends must be designed jointly. Experiments on LIVECell show that semantic-axis conditioning substantially improves generative fidelity over high-dimensional conditioning, a blind study with biologists confirms the realism of generated cells, and per-axis traversals produce stable and interpretable phenotypic changes.
Aug 4, 2026

Assessment of Conditional Diffusion Model for Synthetic Histopathology Image Generation

Synthetic histopathology image generation has emerged as an approach that may address data scarcity in computational pathology, yet current evaluation methodologies may not fully assess synthetic data quality for medical applications. This work investigates and addresses limitations in existing evaluation metrics, investigating an approach for assessing synthetic histopathology image quality through domain-specific metrics and downstream task validation. We show that conventional synthetic data evaluation metrics such as Frechet Inception Distance (FID) and Inception Score (IS) may have limitations when applied to histopathology images due to their reliance on ImageNet-pretrained feature extractors. To address these limitations, we propose for consideration modified FID and IS approaches utilizing foundation models pretrained on digital pathology datasets, supplemented by precision-recall based metrics as part of an additional quality assessment. Using conditional denoising diffusion models trained on four benchmark datasets, with a two-step training approach, we generated synthetic datasets with systematically varied quality characteristics. We also measured the correlation between the synthetic data quality metrics with downstream nuclei segmentation performance using common metrics including the aggregated Jaccard index (AJI+) and the Dice coefficient. The study results suggest that pathology-specific metrics may provide improved discriminative power. Specifically, the modified Inception Score indicates higher correlation with downstream task performance (r=0.6096 with AJI+, p=0.0122), compared to the original IS (r=0.0708, p=0.7944). Our observations indicate that increasing the variety of generated training data has a higher positive correlation with segmentation model performance than improving the visual fidelity of individual generated images.