cs.LGNov 1, 2026

Robust Remote ECG Monitoring under Energy Constraints: Anomaly Filtering versus Predictive Uncertainty

Authors: Mustafa Fuad Rifet Ibrahim, Maurice Meijer, Alexander Schlaefer, Peer Stelldinger

Organizations: CTO System Innovation, NXP Semiconductors Germany GmbH, Beiersdorfstraße 12, Hamburg, 22529, Germany · Institute of Medical Technology and Intelligent Systems, Hamburg University of Technology, Am Schwarzenberg-Campus 1, Hamburg, 21073, Germany · Faculty of Computer Science and Digital Society, Hamburg University of Applied Sciences, Berliner Tor 5, Hamburg, 20099, Germany · Business Line Secure Connected Edge, NXP Semiconductors, High Tech Campus 60, Eindhoven, 5656, The Netherlands

Abstract

Machine learning for remote electrocardiogram monitoring must handle noise and diseases absent from training under tight resource constraints. We investigate whether upstream unsupervised anomaly detection can improve monitoring decisions more efficiently than classifier-derived uncertainty. We evaluate five detectors on PTB-XL and BUT QDB and compare a two-stage filter-classifier system with Monte Carlo Dropout and deep ensembles under unseen-disease and noise conditions. Performance is averaged over five training seeds. We measure single-pass energy, latency, and graph memory on a microcontroller's central processing unit (CPU) and neural processing unit (NPU). Per-score neural network costs account for repeated evaluations but exclude scoring outside deployed graphs. Energy equations relate filtering and rejection to avoided classifier execution. Across four disease scenarios, Deep Support Vector Data Description (Deep SVDD) achieves the highest mean area under the receiver operating characteristic curve within all tested finite CPU energy budgets. On the NPU, it leads at 1 mJ, while Monte Carlo Dropout has slightly higher means at 10 and 100 mJ. With a narrow CPU classifier, the Deep SVDD two-stage system increases the fraction of correctly classified or correctly rejected inputs by 15.0-19.4 percentage points over classification without rejection. Estimated energy per input is 1.93-6.99 mJ, compared with 52.53 mJ for Monte Carlo Dropout and 8.76-17.51 mJ for deep ensembles, at each method's retrospectively selected test accuracy peak. These results support upstream filtering for efficient remote monitoring, while independent validation and complete-system measurements remain necessary.

Figures & tables

Appendix figures & tables3 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

CardsList
  1. Privacy-Preserving Federated Autoencoder for ECG Anomaly Detection on Edge Devices

    Jun 10, 2026Kaan Arda Akyol, Jakub Kacper Szeląg, Aydin Abadi +9Electrocardiogram ClassificationReconstruction-Based Anomaly Detection

  2. UCTECG-Net: Uncertainty-aware Convolution Transformer ECG Network for Arrhythmia Detection

    Feb 18, 2026Hamzeh Asgharnezhad, Pegah Tabarisaadi, Abbas Khosravi +2Electrocardiogram ClassificationHybrid CNN-Transformer Architectures

  3. ECG-LDC: A Hardware-Efficient Low-Dimensional Computing Framework for ECG Arrhythmia Classification

    Jun 13, 2026Anh Tran, Khanh Tran, Cuong DoEfficient Neural Network InferenceElectrocardiogram Classification