MedPhysBench: A Benchmark for Evaluating Language Models on Medical Physics Calculations and Error Detection

Authors: Omar Nusrat

Organizations: Department of Physics, Toronto Metropolitan University, Toronto, Ontario, Canada · Institute for Biomedical Engineering, Science and Technology (iBEST), St. Michael’s Hospital, Unity Health Toronto, Toronto, Ontario, Canada

Abstract

Medical physicists turn a prescription into a delivered dose and check one another's calculations, because one error in a beam calibration or a monitor-unit (MU) calculation can affect every patient treated with it. MedPhysBench has ten seeded generators of calculation items in radiation therapy, diagnostic imaging, nuclear medicine and radiation protection, up to clinical tasks such as a TG-51 calibration worksheet. Reference answers come from code implementing the governing protocols, and a grader converts units and applies tolerance bands. From the same inputs, separate checking items test error detection, showing a colleague's worksheet or only the colleague's result, half correct and half with one planted error. On a held-out test split of 1,200 items (half for two models), 12 models scored 33.3 to 100.0% on calculation. Of the nine answers graded incorrect for the four best (99.3-100.0%), five contained model errors and four followed NCRP Report 151 on points our items misstate or leave open. Below them, most models did worst on level-3 clinical tasks, and Claude Sonnet 5.5 omitted the inverse-square correction in 19 of 20 isocentric MU items. Five models detected at least 96.7% of mostly large planted errors with at most 4% false alarms; for four of the other seven, checking only the result raised false alarms significantly. In an exploratory targeted test with 20 public cases of an omitted inverse-square correction, the three best models tested caught it in every worksheet, and three weaker models accepted 16 to 18 of 20 planted worksheets, one of them while applying the correction in most of its own calculations. Claude Opus 5.5 accepted 6 of 20 wrong results, although it applied the correction in all 20 of its own. We report the effect of two problems in our shielding items, found after the runs, and release the code, per-item outcomes and targeted-test responses.

Figures & tables

Appendix figures & tables28 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Sep 9, 2026

Towards a Deterministic Math Solver for Clinical Language Models

Large language models are unreliable at arithmetic, which is a problem for clinical calculators where a single numerical error changes the recommendation. The standard response is to hardcode each calculator as a validated function, one at a time. We test an alternative: the model does not calculate. Instead, it writes case-specific Python that a restricted local executor runs as a deterministic solver, and the model's task reduces to deciding how to use it. We evaluate this Program-Solve interface on MedCalc-Bench Verified (1,100 cases, 55 calculators) against direct model arithmetic and a hand-written 22-calculator library, using Qwen2.5-7B and Qwen2.5-32B-AWQ, after auditing the benchmark's formulas against current clinical guidelines and flagging 16 of 55 with version, use or coefficient concerns. With formulas and gold variables supplied and both routes reading the whole note, handing off to the solver is not a reliable advantage at 7B (75.31% against 72.02%, a paired +3.29 points with a 95% calculator-cluster interval of [-3.49, 10.38]) but is one at 32B (90.53% against 83.47%, +7.05 [0.47, 14.60], clear of zero). The hand-written library is exact on its 440 supported cases but abstains elsewhere (40.0% overall). Adding an executor thus helps some open-weight models more than others even under matched formula, variable and note access, and is not a substitute for verified formulas or reliable variable extraction either way.
Jul 3, 2026

MedCalc-Pro: Solving Complex Medical Calculations with LLM Agents

Current benchmarks for evaluating large language models (LLMs) in medical calculation are largely based on simplified settings, where each patient case corresponds to a single calculator and the required tool is explicitly specified in the query. However, real clinical scenarios often require multiple calculators for joint evaluation, nested-scale calculation, and fuzzy queries that do not directly specify the target calculator. To this end, we propose a new medical calculation benchmark, MedCalc-Pro, which covers three progressively challenging task settings: single-calculator, multi-calculator, and nested-calculator calculation settings. MedCalc-Pro contains 2,268 real-world clinical cases, covering 77 medical calculators across 14 clinical departments. Meanwhile, to address the limited performance of existing frameworks and methods in complex clinical scenarios, we further propose a more generalizable agent framework that supports multi-tool selection and nested-tool calling, while suppressing parameter error propagation through structured validation and evidence review. We conduct systematic comparisons across open-source, closed-source, and medical-specialized LLMs, and the results show that our framework achieves the best performance across all three task settings. This work provides a new benchmark and method for evaluating and applying LLMs in challenging medical calculation scenarios.
Oct 28, 2026

Benchmarking decision models against generative large language models on medical multiple-choice questions

Medical workflows often require selecting among predefined options. We compared 13 decision models with 15 generative large language model configurations, including different reasoning settings, using 1,273 four-option MedQA questions under text-only conditions. Accuracy ranged from 67.71% to 89.08% for decision models and from 78.32% to 96.86% for generative configurations. Among the tested configurations, Mercury Decide had the lowest mean final-attempt cost (USD 0.0069 per 1,000 questions), while Clef Omni had the shortest median request duration (0.291 seconds). Decision-model probabilities distinguished correct from incorrect answers, but error rates among answers assigned probabilities of at least 0.90 ranged from 1.71% to 12.77%. Answer agreement across three runs ranged from 92.30% to 100%, while probability repeatability varied. Decision models offered resource advantages alongside lower peak accuracy; selecting models for medical workflows requires considering probability quality and repeatability together with accuracy and the resources needed to detect and correct errors.