cs.CVNov 6, 2026

STAIRS: Staging the Inverse Problem via Admissible-Support Scheduling for Unrolled MRI Reconstruction

Authors: Xiangjian Hou, Chang Ni, Chao Qin, Zhiwei Tan, Xin Wang, Xinrui Ye, Rong-Rong Chen, Chun Yuan, 

Organizations: Department of Radiology and Imaging Sciences and the Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112, USA · Department of Radiology and Imaging Sciences and the Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA · Department of Computer Vision, Mohamed bin Zayed University of Artificial Intelligence, Abu Dhabi, United Arab Emirates · Department of Electrical and Computer Engineering, University of Washington, Seattle, WA 98195, USA · 

Abstract

Accelerated magnetic resonance imaging (MRI) forms images from incomplete Fourier measurements, shifting acquisition burden to computational reconstruction. Deep unrolled networks interleave learned regularization and data consistency, yet typically estimate the full unmeasured spectrum at every cascade. We propose STAIRS (Staging the Inverse Problem via Admissible-Support Scheduling), which projects intermediate reconstructions onto nested Fourier supports that expand to the full spectrum and conditions each update on its support transition. Conditional increments of a regularized log-determinant score of training covariance define a normalized spectral coordinate, accounting for dependencies between newly and previously admitted frequencies. Dyadic targets allocate larger coordinate increments to earlier cascades and are mapped to fixed supports before training, enabling coarse-to-fine reconstruction with unchanged sampling masks and data consistency. On fastMRI and Stanford2D, STAIRS improves matched Transformer (HUMUSNet) and convolutional (NAFNet) backbones in single- and multi-coil reconstruction, including radiologist-annotated pathology regions. It also outperforms predictor-based progression with lower parameter overhead and inference latency. Stage-wise analysis shows repeated error correction by projection and lower intermediate reconstruction errors than the backbones alone throughout support expansion. Ablations favor dyadic allocation over uniform expansion for square and line-band supports and over manual front-loading for square windows. Support projection alone improves reconstruction, and transition conditioning strengthens the gain. Cross-dataset evaluation shows improvements for both backbones in both directions. Support allocation thus complements regularizer design in unrolled MRI reconstruction.

Figures & tables

Explore similar work

Oct 24, 2026

Scalable Unrolled Chains for MRI Reconstruction

Unrolled variational networks achieve state-of-the-art performance for accelerated MRI reconstruction, but standard end-to-end training becomes prohibitively memory intensive as the number and width of cascades increase. We propose a memory-efficient training framework that updates a randomly sampled cascade while retaining supervision from the final reconstruction loss. The error signal is propagated from the end of the chain to the sampled cascade using an activation-light backward pass that avoids storing full chain activations, thereby decoupling training memory from chain length. A time-conditioned network shared across cascades further keeps the parameter count independent of chain length. The backward pass is approximate only through frozen normalization statistics, and a trained exact gradient control shows the approximation leaves reconstruction quality unchanged. The framework remains trainable at chain lengths and cascade widths where standard end-to-end backpropagation exhausts GPU memory. On fastMRI single-coil knee and multi-coil brain reconstruction, our method consistently outperforms other local training approaches. On high-SNR knee slices, our method surpasses E2E-VarNet at 8×8\times and matches it at 4×4\times, while on the complete brain validation set it surpasses E2E-VarNet at 8×8\times and achieves comparable performance at 4×4\times, with fewer parameters, lower peak memory, and faster per-iteration training. Code is available at https://github.com/emehillaj/scalable-unrolled-mri.
Oct 9, 2026

Stochastic Finite-Transition Learning and Exploration for Accelerated MRI Reconstruction

Generative MRI reconstruction maps an initial source distribution to the target image distribution along a learned recovery trajectory. Common generative methods, such as diffusion and flow, typically learn fine-grained local dynamics whose integration defines this global mapping, hence requiring many network evaluations at inference. Existing few-step sampling approaches can lower computational burden by approximating large transformations from local dynamics, albeit at the expense of reconstruction fidelity. FLEX-MRI instead partitions recovery into a small number of finite intervals between retained states defined by progressive changes in k-space support, and directly learns the reconstruction change across each interval. Because such finite transitions can admit multiple plausible outcomes, FLEX-MRI combines support-relaxed finite-transition learning with stochastic exploration. During training, randomized k-space sampling masks define finite-transition targets with varying support, while the prediction loss remains unrestricted by each individual mask. At inference, FLEX-MRI perturbs a random subset of currently estimated k-space coefficients, allowing the learned predictor to stochastically explore alternative transition paths. Each predicted state is then reconciled with the acquired measurements through data consistency. We theoretically show that this stochastic exploration induces nonzero transition-level variation through the learned recovery map and data consistency without requiring an auxiliary generative sampler. Experiments on multi-coil MRI datasets show that FLEX-MRI outperforms competing methods while maintaining computational efficiency comparable to few-step baselines.
Nov 11, 2026

One Block Is Enough: LoopMR for Accelerated MRI Reconstruction

Deep-learning unrolled networks are the leading approach to accelerated MRI reconstruction. State-of-the-art models such as PromptMR+ learn a distinct block for every cascade, so their size grows with the number of cascades. Sharing one block across iterations avoids adding parameters, but earlier shared-weight models typically used a tiny block and produced worse images than models with distinct weights. Therefore, it remained unclear whether weight sharing itself or the choice of block was the problem. Recent advances in looped transformers, which reuse the same block across layers, show that they can match or outperform their distinct-weight counterparts on several tasks. Motivated by this, we propose LoopMR, which reuses a single Restormer block at every iteration as its core. Besides the current image estimate, the block receives data-consistency inputs and latent images. On four datasets covering the brain (CC359), knee (fastMRI), heart (CMRxRecon2023) and carotid (in-house), LoopMR significantly outperforms E2E-VarNet, PromptMR and PromptMR+ in PSNR and SSIM at every acceleration factor (p < 0.01), with about 1/9 of PromptMR+'s parameters (10.3M versus 92.9M). It also keeps its lead at unseen acceleration factors and on an unseen dataset. With our transformer block, the shared model matches or outperforms its distinct-weight counterpart at 6, 12 and 24 iterations. At a fixed number of iterations, shared transformer blocks match or outperform their distinct-weight versions, while shared CNN blocks perform worse. These results suggest that looping one well-chosen block can outperform stacking distinct cascades in MRI reconstruction, with a fraction of the parameters.