Can General-Purpose Generative AI Supply Training Data for Medical Vision Models? A Multimodal Retrospective Study

Authors: Jiachuan Peng, Kyle Lam, Jierui Qu, Lin Li, Haining Zheng, Bang Zheng, Aniruddha Agarwal, Zaki Almallah, 

Organizations: Biological and Life Sciences Division, MBZUAI, UAE. · Department of Engineering Science, University of Oxford, UK. · Department of Surgery and Cancer, Imperial College London, UK. · OATML, Department of Computer Science, University of Oxford, UK. · 

Abstract

Background: Well-annotated, diverse medical imaging datasets remain a major constraint for vision-based medical AI. We evaluated Nano Banana, a general-purpose image generation and editing model, as a source of synthetic medical images for model training, subgroup augmentation, and model auditing. Methods: In this retrospective study across four imaging modalities, chest radiography, fundus photography, and CT models were trained only on synthetic images and externally validated on real-world data against real-data-trained models. Carotid ultrasound models were trained on a private Human Phenotype Project cohort (aged 40-75 years) with and without synthetic augmentation. Clinicians rated image plausibility. Evaluation used AUROC, AUPR, calibration, and decision curve analysis. Findings: Synthetic-only models achieved AUROCs of 0.877 (95% CI 0.843-0.910) for pneumonia (n=14863), 0.963 (0.948-0.975) for retinal detachment (n=1149), and 0.711 (0.600-0.823) for renal calculus (n=4122), comparable to real-data-trained models, but their calibration and net benefit were not consistently more favorable. With mixed synthetic-real training, a carotid ultrasound model produced an ordinal vascular age index that stratified 633 external subjects into subgroups differing in BMI and glucose (both p<0.01), linking vascular aging to cardiometabolic health. To stress-test shortcut learning, editing a moderate tessellated pattern into fundus photographs reduced the true-class probability for central serous chorioretinopathy from 0.996 to 0.822. Clinician-guided editing raised low-quality CT plausibility from 3.10/5 to 4.30/5. Interpretation: Synthetic data can complement real data in model training, subgroup representation, and model testing via controlled editing, but its clinical value should be assessed with calibration, decision curve analysis, and clinician review, not discrimination alone.

Figures & tables

Explore similar work

Jun 24, 2026

Text Over Image: Auditing Multimodal Robustness in Synthetic Medical Image Detection

With the rapid adoption of generative AI, synthetic medical images pose growing risks, including diagnostic deception and insurance fraud. Although prior work has explored vision-language model (VLM)-based synthetic image detection, these evaluations typically consider images in isolation. In clinical practice, however, images are interpreted alongside structured records and metadata, and VLMs are increasingly deployed under joint image-record inputs. We uncover a previously underexamined multimodal vulnerability: when given both modalities, VLMs may overweight record context in authenticity judgments, such that the same image receives different predictions solely due to changes in its accompanying text. This raises concerns about robustness in real-world deployment. To systematically characterize this effect, we reformulate synthetic medical image detection as an audit of multimodal robustness at the image-record interface and introduce a paired benchmark that holds the image fixed while swapping controlled metadata variants. Across multiple imaging modalities, we evaluate diverse open-weight and frontier API VLMs and find that changing the metadata context alone can flip authenticity judgments, with accuracy on authentic images dropping by 61.1% on average under an explicit AI-origin tag. We further propose an inference-time mitigation pipeline that detects and neutralizes provenance shortcuts without model retraining, substantially outperforming direct prompt-based suppression on the affected subset. Our benchmark provides a standardized tool for assessing and improving multimodal robustness beyond image-only settings. Code and data will be released upon acceptance.
Aug 13, 2026

Evaluation of Clinically Steerable Retinal Image Generation from Foundation Model Latent Spaces

Medical foundation models learn latent representations of clinically meaningful phenotypes, yet their ability to support controllable image generation remains largely unexplored. We evaluate four retinal foundation models within the representation tokenizer framework and examine whether demographic and clinical information encoded in latent representations from foundation models is preserved during synthetic image generation. We show that generated representations and images faithfully inherit phenotype information when evaluated within their originating foundation models, consistently outperforming conventional latent diffusion on multiple downstream prediction tasks. However, these gains largely disappear when evaluated using classifiers trained on real images, revealing a previously uncharacterised synthetic-to-real representation gap. These findings demonstrate that foundation-model latent spaces provide a powerful substrate for controllable retinal synthesis while highlighting the need to better align synthetic representations with real-image distributions.
May 21, 2026

Do Synthetic Brain MRIs Reliably Improve Tumour Classification? A StyleGAN2-ADA Class-Plane Augmentation Study on BRISC 2025

Generative augmentation is often proposed as a remedy for small medical-image datasets, but synthetic images are only useful when they improve downstream task performance. "Augmentation" here means synthetic supplementation: GAN-generated samples added to the real training pool, not geometric or photometric transforms of existing images. Twelve class-plane StyleGAN2-ADA generators were trained on constrained BRISC 2025 partitions to test whether their output, with or without InceptionV3 feature-space filtering, improves held-out tumour classification across three classifier families: a random forest (RF) on InceptionV3 features, a compact two-headed convolutional neural network (CNN), and MobileViTV2, a mobile hybrid convolutional-transformer. Each was evaluated at 1:1 and 1:2 real-to-synthetic ratios. An independent GPT-5.5 blind test placed gated real-versus-synthetic discrimination at 57.73% (95% CI: 54.48--60.92%) on the model-legible subset -- modestly above chance. The RF classifier did not benefit from the synthetic MRIs. The CNN showed consistent mean gains that did not survive Holm correction. MobileViTV2 showed the clearest benefit: filtered 1:1 augmentation improved tumour classification accuracy by 1.02% absolute (95% CI: 0.54--1.54%; Holm-corrected p = 0.0104). A secondary efficiency analysis found that every augmented CNN condition selected its checkpoint 42--64% earlier than baseline, while compute-matched MobileViTV2 runs reached selection after 50--67% fewer real-data epochs. Overall, augmentation utility was found to be architecture- and ratio-dependent, not guaranteed by visual fidelity alone.