Continuous Cuffless Blood Pressure Estimation Using PPG From Methods to Clinical Translation

Authors: Karthika Shalini Potail, Harshitha Manjunatha, Hetvi Kotadia, Tooraj Nikoubin

Organizations: Department of Electrical and Computer Engineering, The University of Texas at Dallas, Richardson, USA

Abstract

Continuous blood pressure (BP) monitoring could improve hypertension management by capturing changes that intermittent cuff measurements miss. Photoplethysmography (PPG) is widely explored for cuffless BP estimation because optical sensors are inexpensive, wearable, and already present in many consumer and clinical devices. PPG, however, does not measure arterial pressure: BP is inferred from waveform characteristics or pulse timing, which also depend on vascular tone, arterial stiffness, sensor contact, motion, and individual physiology. This survey reviews PPG-based cuffless BP estimation along the full measurement chain, covering physiological mechanisms, waveform features, pulse arrival time (PAT), pulse transit time (PTT), machine-learning methods, datasets, calibration, validation, deployment, bias, and clinical translation. Studies are assessed by the strength of evidence they provide rather than by reported error alone, with particular attention to subject and temporal leakage, dataset imbalance, calibration dependence and drift, motion artifacts, and the gap between benchmark accuracy and reliable real-world measurement. The review finds that progress depends on more than better prediction algorithms. Future work should prioritize physiologically informed models, diverse longitudinal datasets, transparent reporting of calibration requirements and failure rates, stronger evaluation protocols, and studies that demonstrate practical value in clinical care.

Figures & tables

Explore similar work

Jul 29, 2026

Single-Beat Cuffless Blood Pressure Estimation Using Ear-PPG and ECG with a Lightweight Hybrid Learning Framework

Continuous cuffless blood pressure (BP) monitoring remains challenging due to motion artifacts, physiological variability, and the limited robustness of conventional pulse transit time (PTT) models under dynamic conditions. Many prior approaches rely on multi-second windows to stabilize estimation, an assumption that is frequently violated during real-world monitoring with intermittent signal corruption. Here, we show that discriminative BP-related information is preserved at the single-beat level and present a lightweight multi-modal wearable framework for continuous BP estimation. The system integrates synchronized chest electrocardiography (ECG) and ear-clip reflectance photoplethysmography, each co-located with a 6-axis inertial measurement unit to provide motion context. We introduce a hybrid learning architecture in which a one-dimensional convolutional neural network extracts a 64-dimensional embedding from individual PPG beats and fuses it with 30 physiology-grounded features, including PTT statistics and heart rate variability, followed by LightGBM regression. The method was evaluated using a multi-phase stress protocol (n=10n=10) and the PulseDB public dataset with subject-disjoint validation. Across 30 independent runs, the model achieved mean absolute errors of 4.02±0.214.02 \pm 0.21~mmHg for systolic BP and 1.79±0.051.79 \pm 0.05~mmHg for diastolic BP, corresponding to a 28.2% reduction in combined MAE relative to baseline models. By enabling beat-wise estimation without long temporal context, this framework supports computationally efficient cuffless BP monitoring suitable for wearable deployment under practical resource constraints. The source code for this work is available at https://github.com/SYMBIOX-Lab/BP-wireless.
Jul 26, 2026

Blood Pressure Estimation from PPG: A Comparative Study of Direct and ECG-Mediated Deep Learning Pipelines

Continuous cuffless blood pressure (BP) monitoring is essential for connected health systems and wearable devices, enabling early detection, longitudinal tracking, and personalized management of cardiovascular disease. Many prior approaches attempt to estimate BP indirectly by reconstructing electrocardiography (ECG) from photoplethysmography (PPG), assuming ECG provides a stronger physiological link to BP. However, ECG sensing is less accessible in wearable settings and may introduce unnecessary complexity. In this work, we first perform a large-scale physiological correlation analysis on the MIMIC-III waveform database, revealing that PPG exhibits substantially stronger coupling with arterial blood pressure (ABP) (∣r∣=0.247|r|=0.247, p<0.001p<0.001) than ECG does (r=0.018r=0.018, p=0.187p=0.187), challenging the assumption that ECG provides a superior intermediate representation. Motivated by this insight, we conduct a systematic comparison between direct PPG-to-BP prediction and ECG-mediated pipelines using multiple state-of-the-art deep learning models. Across 1.74M segments from 3,127 patients, direct PPG-to-BP prediction achieves British Hypertension Society Grade A performance (MAESBP=4.82mmHg\mathrm{MAE}_{\mathrm{SBP}} = 4.82 mmHg, MAEDBP=4.31mmHg\mathrm{MAE}_{\mathrm{DBP}} = 4.31 mmHg), outperforming all ECG-mediated approaches, which achieve only Grade B accuracy. Our findings suggest that accurate continuous BP monitoring can be achieved directly from wearable PPG signals, enabling simpler, more efficient pipelines for real-world connected health systems.
Apr 15, 2024

TransfoRhythm: A Transformer Architecture Conductive to Blood Pressure Estimation via Solo PPG Signal Capturing

Recent statistics indicate that approximately 1.3 billion individuals worldwide suffer from hypertension, a leading cause of premature death globally. Blood Pressure (BP) serves as a critical health indicator for accurate and timely diagnosis and/or treatment of hypertension. Traditional BP measurement methods rely on cuff-based approaches, which lack real-time, continuous, and reliable BP estimates, crucial for the timely diagnosis/treatment of hypertension. Driven by recent advancements in Artificial Intelligence (AI) and Deep Neural Networks (DNNs), there has been a surge of interest in developing data-driven and cuff-less BP estimation solutions. In this context, current literature predominantly focuses on coupling Electrocardiography (ECG) and Photoplethysmography (PPG) sensors, though this approach is constrained by reliance on multiple sensor types. An alternative, utilizing standalone PPG signals, presents challenges due to the absence of auxiliary sensors (ECG), requiring the use of morphological features while addressing motion artifacts and high-frequency noise. To address these issues, the paper introduces the TransfoRhythm framework, a Transformer-based DNN architecture built upon the recently released physiological database, MIMIC-IV. Leveraging the Multi-Head Attention (MHA) mechanism, TransfoRhythm identifies dependencies and similarities across data segments, forming a robust framework for cuff-less BP estimation solely using PPG signals. To our knowledge, this paper represents the first study to apply the MIMIC IV dataset for cuff-less BP estimation. TransfoRhythm achieves highly accurate results with a Root Mean Square Error (RMSE) of [2.21, 1.84] and a Mean Absolute Error (MAE) of [1.37, 1.06] for systolic and diastolic blood pressures, respectively.