TotalSegmentator Aorta Report: Automated Aortic Diameter Measurement at 11 Standardized Landmarks on CT Images

Authors: Jakob Wasserthal, Daniel Hinck, Martin Segeroth, Joshy Cyriac, Denis Berdajs, Jules Miazza, Maurice Pradella

Organizations: Clinic of Radiology and Nuclear Medicine, University Hospital Basel, Basel, Switzerland · Department of Cardiac Surgery, University Hospital Basel, University of Basel, Basel, Switzerland

Abstract

Purpose: To develop and evaluate a fully automated, open-source tool that measures aortic diameters at 11 standardized landmarks from the aortic annulus to the bifurcation on any CT image, following current guideline recommendations. Materials and Methods: This retrospective single-center study included 239 arterial phase CT angiography examinations of 230 patients (median age, 65 years [range, 18-99 years]; 163 men) performed between April 2025 and October 2026 (209 electrocardiographically [ECG] gated). The tool locates landmarks from TotalSegmentator segmentations of aortic branches and vertebrae and measures the maximum diameter at each. A senior radiologist reviewed and, where needed, corrected the automated measurements to create the reference standard. Agreement was assessed with mean absolute error (MAE), bias, and differences greater than 2 mm. Results: Across all landmarks, MAE was 1.06 mm (95% CI: 0.91, 1.22), and 86.6% (95% CI: 84.4, 88.5) of differences were 2 mm or less. The tool measured slightly larger diameters (bias, 0.45 mm [95% CI: 0.34, 0.57]). The sinuses of Valsalva had the largest MAE (2.17 mm [95% CI: 1.59, 2.86]). For 1.2% of landmarks, the automatic measurement failed. Examination-level MAE did not differ significantly by pathology, atherosclerosis grade (P=.95), or ECG gating (P=.14). Examinations with mural thrombus more often had an MAE greater than 2 mm (50% [95% CI: 31, 69] vs 20%; P=.03). Conclusion: The tool measured aortic diameters at 11 landmarks along the entire aorta with an MAE of about 1 mm, below published interreader variability. Agreement was lower at the aortic root and with mural thrombus. Code availability: The tool is open source and freely available at https://github.com/wasserth/TotalSegmentator.

Figures & tables

Explore similar work

Jul 31, 2026

TAVI-TEC: An AI-Based Tool for Procedural Planning of Transcatheter Aortic Valve Implantation

Computed tomography angiography (CTA) is crucial for preprocedural TAVI planning, providing the anatomical information required for prosthesis sizing and vascular access assessment. As the volume of TAVI procedure increases, improving efficiency and standardizing annotations is becoming essential in clinical practice. This study presents TAVI-TEC, a fully automated artificial intelligence-based framework integrated into a web based DICOM viewer for routine preoperative TAVI planning. Pre-procedural CTA scans from patients undergoing TAVI with SAPIEN 3 Ultra (S3U) prostheses were processed using a fully automated pipeline. Deep learning-based segmentation of cardiovascular structures, calcification detection, centerline extraction, landmark identification, and annular plane definition was implemented to quantify key annular and aortic root measurements and color-coded maps of lumen reduction and vessel diameter for vascular access. A multilayer perceptron classifier was trained to predict prosthesis size prior to the TAVI procedure. Results revealed that TAVI-TEC enabled pre-procedural measurements in approximately 2-6 min. Strong agreement with clinician-derived measurements was observed for annular area (coefficient of concordance, CCC = 0.934; interclass correlation coefficient, ICC = 0.935; R^2 = 0.881) and perimeter (CCC = 0.909; ICC = 0.909; R^2 = 0.854). The valve-size prediction model achieved 82% overall accuracy, with most misclassifications occurring between adjacent prosthesis sizes. Though further multicenter validation and extension to additional measurements and valve platforms are required, the TAVI-TEC methodology may reduce operator variability in pre-TAVI measurements and streamline the preoperative workflows of the Heart Team for decision-making.
Aug 31, 2026

ImageCAS-X: a dataset and benchmark for coronary artery segmentation and centerline extraction in coronary CT angiography

Accurate segmentation of the coronary vessel lumen is a prerequisite for quantitative assessment of atherosclerotic plaque and perivascular adipose tissue in coronary computed tomography angiography (CCTA). Cardiologists rely on semi-automated methods for this task because manual vessel tracing and segmentation are labour-intensive. Although many automated methods have been proposed, their validation remains limited by the lack of large, high-quality publicly available datasets. We provide a new dataset of voxel-wise annotations of the vessel lumen and coronary segments, alongside centerlines, and mesh surfaces for 800 scans from the publicly available ImageCAS dataset. Using this dataset, we benchmark established lumen segmentation methods against inter-observer variability, stratifying performance by disease, image quality, coronary dominance, coronary segment, vessel diameter, and lumen attenuation. These labels allow segmentation accuracy to be described in anatomical and clinical context rather than reported as a single aggregate score. The dataset supports the development and validation of methods for lumen segmentation, plaque and perivascular quantification, and haemodynamic modelling.
Nov 6, 2026

Beyond Segmentation: Enriching ImageCAS with Coronary Ostia Landmarks, Rooted Centerline Graphs, and Open-Weight Localization Models

Coronary ostia and centerlines are key reference points for automated analysis of coronary computed tomography angiography (CCTA), from surgical planning to intraoperative vessel tracking. However, the only public ostium annotations cover 77 non-gated aortic scans, not CCTA, while CAT08 and ASOCA (32 and 40 CCTA scans) mark the ostia only implicitly, as centerline start points. This work enriches ImageCAS, the largest public dataset for coronary artery segmentation, with ostium annotations for its 1000 patients and centerline graphs rooted at these new ostia, making it, to the authors' knowledge, the largest public dataset for ostium localization and the only one with centerlines following the official ImageCAS masks and starting at annotated ostia. Three annotators marked each ostium in the first 500 volumes; in the next 500, the candidates of a model trained on the first batch were corrected (human-in-the-loop). Six 3D localization models, trained on ImageCAS, CAT08 and ASOCA, were benchmarked on 58 held-out volumes (50 ImageCAS, 4 CAT08, 4 ASOCA). SwinUNETR-V2 and nnResUNet localized all ostia without failure (>5 mm error), with median errors of 0.70-0.87 mm. Trained on CAT08 and ASOCA alone, SwinUNETR-V2 fails on 34% of right and 53% of left ostia, whereas adding 250 ImageCAS volumes removes all failures. The centerlines were extracted by a deterministic, quality-controlled minimal-path procedure; on ASOCA, they cover a median of 99.5% of the reference length, with a median per-patient mean distance of 0.22 mm between matched reference points and centerlines. Annotations, centerlines, code, and weights are available at https://hal9000-lab.github.io/.