cs.RONov 14, 2026

Continuous Lower-Limb Joint-Angle Estimation from sEMG and IMU: The Conditional Value of Cross-Activity and Cross-Subject Data under Update-Matched Controls

Authors: Jiaying Xu, Guangyuan Chen, Buyun Gao, Zhen Dong

Organizations: Conamur · Conamur, Palo Alto, CA, USA. · Institute of Neuroscience, Chinese Academy of Sciences · Institute of Neuroscience, Chinese Academy of Sciences, Shanghai, China. · 

Abstract

Intent-driven exoskeleton control needs a continuous, causal estimate of the wearer's joint kinematics and an answer to a second question: whose data should train the estimator for a new user? Borrowing the user's recordings of other activities, or other users' recordings of the same activity, is usually evaluated as "more data" versus "less data," which confounds the information a source carries with the optimizer updates it adds and hides negative transfer behind averages. We separate these effects for hip, knee, and ankle angle estimation from high-density sEMG and an IMU across six locomotion activities on all ten participants of a public dataset. A compact residual causal TCN-GRU decoder is frozen, and an update-matched replay control prices every added source against the same number of updates on the user's own data. A user's own other activities raise R2R^2 from 0.722 to 0.788, of which +0.048 is information beyond replay; stair descent is a reliably harmful donor and sit-stand-walk a reliably beneficial one. Other users' same-activity data help while the user has only the target activity (GT=+0.053G_\mathrm{T} = +0.053) and half as much once own other-activity data exist (GW=+0.028G_\mathrm{W} = +0.028); at full calibration, donor value collapses after one to two target records. Per-target gains from the two sources correlate, and leave-one-participant-out gates recover most of the cross-subject value only at low calibration. Data value is hierarchical, state-dependent, and directional; the bottleneck is deciding, without test labels, when to transfer.

Figures & tables

Explore similar work

Oct 6, 2026

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.
Mar 8, 2026

Exoskeleton Control through Learning to Reduce Biological Joint Moments in Simulations

Data-driven joint-moment predictors offer a scalable alternative to laboratory-based inverse-dynamics pipelines for biomechanics estimation and exoskeleton control. Meanwhile, physics-based reinforcement learning (RL) enables simulation-trained controllers to learn dynamics-aware assistance strategies without extensive human experimentation. However, quantitative verification of simulation-trained exoskeleton torque predictors, and their impact on human joint power injection, remains limited. This paper presents (1) an RL framework to learn exoskeleton assistance policies that reduce biological joint moments, and (2) a validation pipeline that verifies the trained control networks using an open-source gait dataset through inference and comparison with biological joint moments. Simulation-trained multilayer perceptron (MLP) controllers are developed for level-ground and ramp walking, mapping short-horizon histories of bilateral hip and knee kinematics to normalized assistance torques. Results show that predicted assistance preserves task-intensity trends across speeds and inclines. Agreement is particularly strong at the hip, with cross-correlation coefficients reaching 0.94 at 1.8 m/s and 0.98 during 5° decline walking, demonstrating near-matched temporal structure. Discrepancies increase at higher speeds and steeper inclines, especially at the knee, and are more pronounced in joint power comparisons. Delay tuning biases assistance toward greater positive power injection; modest timing shifts increase positive power and improve agreement in specific gait intervals. Together, these results establish a quantitative validation framework for simulation-trained exoskeleton controllers, demonstrate strong sim-to-data consistency at the torque level, and highlight both the promise and the remaining challenges for sim-to-real transfer.
Oct 30, 2026

Design and Validation of a Robotic Knee Exoskeleton with Musculoskeletal Simulation-Derived Biological Torque Control

Data-driven controllers have enabled lower-limb robotic exoskeletons to adapt assistance to the user across many tasks. A leading example is biological torque control, which estimates the user's own joint moment from onboard sensors and assists in proportion to that estimate. However, its estimators are trained on data recorded with the target device, so deploying the controller on new hardware requires collecting new data. Existing open-source efforts release hardware, software, or controllers separately, so this data collection must still be repeated on the assembled device. Here, we present an open-source knee exoskeleton, built from off-the-shelf components and widely available fabrication tools, with a biological torque controller derived entirely from simulation. A muscle-driven imitation policy reproduces squatting motions from an open biomechanics dataset, and the resulting knee moments are distilled into an estimator that uses only onboard sensors, so no training data are recorded on the device. In seven able-bodied participants, assistance reduced peak biological knee extension moment by 21.5% and peak vastus medialis activation by 26.7% during squatting, relative to squatting without the exoskeleton (p<0.05). Our results demonstrate that a biological torque controller derived from simulation can transfer to physical hardware without device-specific data collection. Because the hardware and training pipeline are released together, research groups can train and compare knee exoskeleton controllers on shared hardware without additional data collection overhead.