In indoor 3D localization inside multistory buildings, an elevator or an escalator accelerates for a few seconds and then cruises at constant velocity for tens of seconds. Gait excitation disappears, the specific force degenerates into a constant gravity reaction, and instantaneous velocity becomes unobservable within a 1-2 s window. The output of short-window learned inertial odometry consequently degrades toward the conditional mean of the training set, and vertical displacement is systematically underestimated. We propose Local-Token Causal Attention (LTCA), a long-horizon architecture that compresses each 1 s inertial window into a 1 Hz motion token and sustains, over a bounded 60 s causal cache, the motion state established at the onset event. We further introduce a pluggable barometer branch that, when online, supplies a direct elevation constraint to the vertical channel through local differential height observations, and we train it with paired online/fallback conditional training so that the barometer also regularizes the representation shared by the two modes during training. On MSIO, our benchmark of nine buildings, the RoNIN and TLIO instances reach 3D trajectory errors (ATE-3D) of 2.83/4.18 m and 2.44/5.12 m on the Seen and Unseen splits, respectively, with the barometer online. With the barometer disabled at inference, the same weights fall back to pure inertial inference and reach 3.24/4.28 m and 2.64/5.23 m, still below every native short-window baseline. We further validate the framework on the public RoNIN and TLIO benchmarks.
Figures & tables
Split
Seq.
Dur. (h)
Description
Training
290
29.34
Used for training
Validation
30
2.64
Used for model selection
Seen test
30
2.61
Buildings seen in training; sessions disjoint from training
Unseen test
17
1.67
Buildings and test subjects unseen in training
TABLE I: Splits of the MSIO dataset. All sequences were recorded with a 100 Hz six-axis IMU and a synchronized barometer; reference trajectories were generated by LiDAR-inertial mapping. The Unseen split participates in neither training nor model selection.
(a) Seen
Model
LTCA
Baro
Mode
ATE-3D
ATE-XY
Z-RMSE
RTE-60s
DTE-1m
Native RoNIN
×
×
–
5.64
3.93
3.54
3.60
0.31
Native TLIO
×
×
–
5.91
3.57
4.23
4.01
0.31
IDOL
×
×
–
5.87
3.95
3.89
3.99
0.32
CTIN
×
×
–
5.68
3.52
3.90
3.69
0.30
EqNIO
×
×
–
5.48
3.45
3.80
3.67
0.30
TABLE II: 3D dead reckoning results on MSIO. For each backbone, “online” and “fallback” are two inference modes of the same set of weights; IDOL is inferred with a 1 s window following its official deployment configuration. Best results on each split are in bold. Unit: m.
Fig. 1: Error cumulative distributions over the 17 Unseen sequences: (a) ATE-3D; (b) Z-RMSE; (c) RTE-60s ( n=17 ).
Fig. 2: Planar trajectories of four representative sequences: (a) and (d) are Seen sequences that contain elevator segments, (b) is a Seen sequence without elevators, and (c) is an Unseen sequence. Ground truth, the native baselines, and the complete architecture in online and fallback modes are compared.
(a) Seen
Model
Flat
Stairs
Escalator
Elevator
Native RoNIN
1.10 / 0.18
0.54 / 0.16
1.23 / 1.82
0.28 / 2.79
Native TLIO
1.07 / 0.08
0.44 / 0.13
1.66 / 1.93
0.16 / 3.76
RoNIN-LTCA
0.92 / 0.12
0.49 / 0.11
0.75 / 0.36
0.14 / 0.43
TLIO-LTCA
0.91 / 0.12
0.42 / 0.11
0.65 / 0.34
0.14 / 0.63
RoNIN-LTCA+Baro (online)
0.84 / 0.12
0.46 / 0.10
0.67 / 0.36
0.14 / 0.39
TABLE III: Diagnostic error breakdown by motion mode; each cell reports ATE-XY / Z-RMSE. This table is not comparable with Table II, because within each segment the origin is reset to the segment start and the RMS is computed per segment, then averaged over segments of the same mode; “online” and “fallback” are two inference modes of the same weights. Unit: m.
Fig. 3: Accumulated vertical displacement when the visible history is restricted: (a) 24 s elevator segment; (b) 45 s escalator segment. The horizontal axis is sequence time in (a) and the time since the onset event in (b).
Input condition
Elevator
Escalator
True input
1.358
0.242
Mask attention to event tokens
0.347 ( −74% )
0.175 ( −28% )
Mask attention to control tokens
1.379 (+2%)
0.242 (0%)
TABLE IV: Vertical speed output after masking attention to the onset-event tokens (60 s pure-IMU model, median). The model is the inertial-only model without the barometric branch; masking affects attention only and leaves all other inputs unchanged. Unit: m/s.
Baro at
ATE-3D
Z-RMSE
Cfg.
Training
inference
Seen
Unseen
Seen
Unseen
A
single-path NLL (no barometric branch)
none
3.26
6.91
1.18
2.98
B
paired conditional training
cut (fallback)
2.64
5.23
0.95
1.84
C
paired conditional training
online
2.44
5.12
0.64
1.56
TABLE V: Barometric branch and training conditions (TLIO backbone). A is the pure inertial control without the barometric branch and uses a single-path NLL; B and C are the two inference modes of paired conditional training, B being the fallback configuration in which the availability mask is set to zero at inference. For the RoNIN backbone, A is 3.44/4.55 m, B is 3.24/4.28 m, and C is 2.83/4.18 m. Unit: m.
Fig. 4: Effect of the barometer availability ratio (0–100%) on ATE-3D and Z-RMSE for both backbones: (a)(b) Seen; (c)(d) Unseen.
Model
Split
ATE
RTE-60s
DTE-1m
Native RoNIN
Seen
7.08
4.66
0.23
Native RoNIN
Unseen
10.48
7.29
0.33
RoNIN-LTCA (60 s)
Seen
6.14
4.06
0.18
RoNIN-LTCA (60 s)
Unseen
9.10
6.44
0.27
TABLE VI: Evaluation on the public RoNIN and TLIO benchmarks. Unit: m.
TABLE VII: Ablation on data augmentation. Unit: m.
Metric
TLIO-LTCA
Increase over native TLIO
Parameters
5.66 M
+0.63 M (+12.5%)
Per-step computation (MMACs)
21.67
+1.38 (+6.8%)
Per-step latency (ms, mean/p95)
2.75 / 3.12
—
TABLE VIII: Per-step inference cost (TLIO backbone, batch size 1, FP32). Latency was measured on an Apple M4 CPU; the RoNIN-LTCA+Baro instance takes 3.39 / 3.67 ms. With the KV cache enabled, a step computes only the current token, and the latency is independent of the history length.
This paper presents Elevator-LIO, a LiDAR-inertial odometry framework designed to achieve continuous robot localization during elevator travel, thereby supporting cross-floor robotic tasks. To address the state-estimation problem in non-inertial frames, Elevator-LIO establishes a decoupled state-estimation model that separately models the robot motion relative to the elevator and the elevator motion itself, and embeds it into a mode-dependent iterated error-state Kalman filter framework. This framework degenerates to conventional LIO estimation in ordinary indoor environments, while enabling the propagation and constrained update of elevator-related states in elevator non-inertial environments, thereby achieving continuous and stable localization. An elevator mode manager detects elevator entry and exit events using LiDAR ranging statistics and estimated states, and introduces event-triggered zero-velocity and zero-acceleration updates when the elevator stops to suppress accumulated vertical drift. In addition, this paper adopts an adaptive voxel downsampling strategy to maintain a stable number of effective points under significant environmental scale changes. We conduct extensive experiments on 20 real-world sequences containing 79 elevator rides, including practical challenges such as large-scale spaces, long vertical travel, dynamic pedestrian interference, and mirror reflections. The results show that Elevator-LIO maintains continuous localization accuracy in all sequences, with terminal height error below 1 cm in 17 sequences. In contrast, existing representative localization systems perform poorly on these elevator sequences. Tests on the Hilti 2022/2023 datasets further show that the proposed method remains competitive in standard indoor scenarios. The project page is available at https://xiaofan4122.github.io/Elevator_LIO_Page/.
Learning inertial odometry for a new platform usually requires ground-truth trajectories. We show that an inertial odometry model can instead be trained from scratch by a myopic teacher that integrates the IMU over each short window independently, a scheme we call integration self-supervision. Interestingly, although supervised only by short-window velocity changes, the student learns to directly predict velocity, and does so more accurately than its integration teacher. Pose graph distillation then refines the model with sequence-consistent targets from a pose graph over many windows. Training on a new platform therefore no longer requires collecting ground-truth trajectories, but only calibrating the IMU and recording data during normal operation. Across six datasets spanning pedestrians, drones, quadrupeds, and a humanoid, the same recipe with no velocity or position labels trains models that come within 0.07~m/s average velocity error of a same-architecture supervised baseline.
Yuheng Qiu, Yutian Chen, Carlton Cort +10
Amazon FAR · Carnegie Mellon University · UC Berkeley +2
The training of learned inertial odometry depends on dense, high-precision position ground truth from motion capture, visual-inertial odometry or SLAM, which is costly and hard to acquire at scale. We propose DINS-IO, which learns inertial odometry directly from raw IMU streams without position labels. Our key insight is that the strapdown INS velocity recursion is a strong, fully differentiable consistency prior: the predicted velocity, rotated into the navigation frame, must agree with the integrated specific force up to an unknown initial velocity and a constant accelerometer bias. We cast this constraint as a sliding-window least-squares problem with a globally shared bias, solve it in closed form, and use the solver residual as a self-supervised loss whose gradient flows back to the network through the analytic solution. To supply this per-sample constraint, we design a high-frequency network that emits dense body-frame velocity at the IMU rate. Since the self-supervised network learns consistent motion but its velocity is not yet metrically calibrated, we calibrate it to true metric velocity from a few labeled trajectories by directly supervising the predicted body-frame velocity and adapting only low-rank (LoRA) patches. On standard benchmarks, DINS-IO pretrained self-supervised and fine-tuned with a small fraction of labels matches or surpasses fully supervised baselines.
Hao Qiao, Yan Wang, Jian Kuang +1
School of Geodesy and Geomatics, Wuhan University · GNSS Research Center, Wuhan University · Hubei Luojia Laboratory