cs.CVNov 15, 2026

SEAT: Sign-Type Evidence-Audited Transport for Multi-Label Tongue Diagnosis

Authors: Liuyi Xu, Qing Wang, Zikai Liang, An-Yang Lu, Yining Qian

Organizations: College of Information Science and Engineering, Northeastern University, Shenyang, China · College of Sciences, Northeastern University, Shenyang, China · School of Computer and Communication Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, Hebei, China

Abstract

Automated tongue-sign recognition can improve the consistency of non-invasive examinations that otherwise rely on subjective visual judgment. A single tongue image often exhibits multiple coexisting signs characterized by heterogeneous evidence, including localized morphology, global chromaticity, and inter-label dependence. However, existing methods typically rely on shared representations and uniform multi-label heads, making it difficult to verify whether predictions stem from clinically relevant evidence rather than spurious visual correlations. We propose SEAT, an evidence-audited framework that matches distinct evidence types with dedicated prediction and evaluation mechanisms. Built on frozen DINOv2 patch features, SEAT couples mask-guided sign-specific attention for localized morphology, a semi-relaxed optimal transport pathway over LAB/HSV color prototypes to enhance pale-tongue recognition, and a co-occurrence-aware transport regularizer to shape the batch-level predicted label marginal. These components are evaluated through audits matched to their evidence types. On the TongueDx benchmark, SEAT achieves a mean macro-F1 of 72.59 with a standard deviation of 1.04 across six random seeds, with a six-model ensemble reaching 74.15. The ensemble outperforms a backbone-matched baseline and a larger, domain-specialized vision-language model by 8.06 and 2.99 percentage points, respectively. Our results demonstrate that aligning dedicated prediction pathways and audits with sign-specific characteristics improves multi-label accuracy while offering more targeted evidential grounding than uniform post-hoc spatial explanations. Code is available at https://github.com/NEU-TCM-Lab/Sign-type-Evidence-Audited-Transport.

Figures & tables

Explore similar work

Jul 30, 2026

What Makes Deep Learning Work for Traditional Chinese Medicine Tongue Diagnosis? A Comprehensive Ablation Study

Deep learning has shown promise for automated tongue diagnosis in traditional Chinese medicine (TCM), yet the design space remains underexplored. We conducted a systematic ablation study spanning 20+ model versions under rigorous 5-fold cross-validation on TongueDx2 (5,109 images, 976 expert-annotated) and a merged dataset of 11,101 samples. We compared six backbone architectures, four loss functions, five augmentation strategies, and six training strategies. The best 976-sample model achieved weighted-F1 of 0.6625 using ConvNeXt-Tiny with restrained augmentation and weak-group ensemble, while the best 11,101-sample model reached weighted-F1 of 0.7761. Six key design principles emerged: (1) ConvNeXt-Tiny offers optimal parameter efficiency; (2) BCE substantially outperforms Asymmetric Loss (+2.7%); (3) restrained color augmentation is critical; (4) weak-group ensemble replacement (+2.1%) outperforms probability averaging; (5) data scaling yielded +20.6% improvement; (6) expanding from 13 to 45 label dimensions caused catastrophic collapse (0.78 to 0.22). These principles are generalizable to multi-label medical image classification with class imbalance.
Nov 17, 2026

OmniTongue: A Comprehensive MLLM Benchmark for Automated Tongue Diagnosis in Traditional Chinese Medicine

Multimodal Large Language Models (MLLMs) have excelled in Western medical imaging, yet their potential in Traditional Chinese Medicine (TCM) tongue diagnosis remains systematically unevaluated. Tongue diagnosis requires sophisticated global and local perception, serving as a rigorous touchstone for assessing the visual understanding depth of MLLMs. However, existing datasets are limited by single dimensions, coarse granularity, and ambiguous labels, hindering the evaluation of authentic clinical capabilities. To bridge this gap, we introduce OmniTongue, the first comprehensive, fine-grained Visual Question Answering benchmark for TCM tongue diagnosis. This benchmark integrates 1,351 expert-validated images and 21,616 instruction pairs. Its core design features 16 clinical dimensions for multidimensional evaluation, region-specific annotations for pathological localization, and 66 fine-grained labels for precise diagnostic representation. Extensive evaluations of existing MLLMs reveal significant performance gaps, demonstrating that medical-specific models lack domain advantages, while universally poor Macro-F1 scores expose a reliance on statistical shortcuts rather than genuine understanding of tongue pathology. These findings not only highlight the current limitations of MLLMs in interpreting regional medical features but also underscore OmniTongue's significance for developing robust automated tongue diagnosis models. The code and dataset will be made publicly available in a future release.
Oct 29, 2026

BEACON: Distilled Begin/End-Aware Structured Decoding for Continuous Sign Language Segmentation

In segmentation-based continuous sign language recognition, an untrimmed video is first partitioned into lexical units; segmentation is therefore a means to an end---downstream recognition. However, segmenters are usually judged by local boundary detection rather than by the quality of the lexical segments and the recognition they enable. We present BEACON, a begin/end-aware segmenter that combines four-class Outside/Begin/Inside/End (BIOE) labeling, constrained Viterbi decoding over eight legal transitions, and boundary knowledge distilled from a binary teacher into a shared student. Under strict no-cut evaluation with validation-based model selection, BEACON improves segment-F1 by 14.58/14.59 points and boundary-F1 by 2.17/1.22 points, and reduces the downstream word error rate (WER) by 9.10/4.15 points relative to the state-of-the-art in the PHOENIX-14/BSL Corpus. To examine which segmentation metric better reflects downstream recognition, we evaluated five distinct architecture families. Segment-F1 aligns more consistently with lower WER than boundary-F1 in both corpora (Spearman ρ=−1.0/−0.9ρ=-1.0/-0.9 versus −0.9/−0.8-0.9/-0.8). These results support evaluating sign language segmentation in terms of segment quality and downstream recognition utility rather than local boundary accuracy alone.