Cyber-Secure Wearable, Ultra-Low-Power Networked Sensors for Soldier Health Monitoring: Insights from the CAPSARII project
Organizations: Sea Sky Technologies, Italy · NTNU, Norway · Politecnico di Milano, Italy · LWT3, Italy ·
Abstract
The CAPSARII project advances a cyber-secure, ultra-low-power wearable platform and Internet of Battlefield Things (IoBT) framework to support real-time monitoring of military personnel and data-driven decision support. The architecture integrates smart-textile sensing, a body/squad area mesh, edge-deployed AI on secure RISC-V microcontrollers, and cloud/federated analytics for cross-mission learning and comparative studies. Two representative use cases--pilot fatigue and warfighters operating in harsh environments--guide requirements, validation, and interface design (including HUD and haptic feedback). As an initial step toward embedded models, we benchmark stress classification on a public wearable dataset: tree-ensemble baselines achieve state-of-the-art performance for accuracy and F1 (e.g., XGBoost: , ), while a feature-based Transformer attains the highest AUC (), informing feature-engineering and compression choices for edge deployment. Building on these results, CAPSARII employs HW/SW co-design, model compression (pruning, quantization, distillation), and precision tuning to meet stringent energy and memory budgets; it further investigates Processing-in-Memory accelerators for future efficiency gains. A structured gap analysis highlights the remaining challenges: establishing validation standards for physiological signal quality and textile durability; achieving low-latency, scalable BAN/SAN communications under mobility and interference; and deploying hybrid lightweight/post-quantum cryptography with robust device identity and side-channel resilience on constrained endpoints. By consolidating these elements into a coherent, secure IoBT stack, CAPSARII delineates a practical roadmap from laboratory baselines to mission-ready soldier monitoring in both training and operational scenarios.
Figures & tables
| Model | Accuracy | Precision | Recall | F1 | AUC |
| SVM | 0.861 0.055 | 0.852 0.046 | 0.934 0.072 | 0.890 0.046 | 0.940 0.032 |
| RF | 0.868 0.060 | 0.844 0.069 | 0.967 0.031 | 0.900 0.043 | 0.962 0.018 |
| XGBoost | 0.901 0.023 | 0.905 0.024 | 0.935 0.023 | 0.920 0.019 | 0.948 0.031 |
| Fully connected | 0.803 0.052 | 0.862 0.037 | 0.806 0.113 | 0.829 0.056 | 0.884 0.046 |
| Transformer (raw) | 0.856 0.058 | 0.889 0.073 | 0.881 0.107 | 0.880 0.050 | 0.962 0.026 |
| Transformer (features) | 0.875 0.054 | 0.905 0.055 | 0.889 0.080 | 0.895 0.046 | 0.963 0.025 |
Wearable Health Monitoring
Wearable health monitoring uses body-worn sensors and AI to track physiological and behavioral signals for continuous, personalized health assessment.