Sparse inertial motion capture typically assumes that each sensor's anatomical identity and mounting orientation are known. We present MOSAIC (Motion-based Sensor Assignment and Inertial Calibration), a framework that recovers this setup from ordinary motion without a calibration pose. Our central insight is that body pose changes continuously while the sensor setup persists, allowing movements that are individually ambiguous to provide complementary evidence over time. A setup network processes unordered sensor streams with temporal and cross-sensor attention, then accumulates assignment and rotation evidence into a session-level estimate. The recovered setup canonicalizes measurements for frozen pretrained pose estimators, separating sensor configuration from motion reconstruction. For sensors worn at prescribed body sites, evaluation on real inertial recordings with randomized setups shows near-calibrated pose accuracy for bounded offsets and substantial benefits from accumulation under arbitrary orientations. Transfer across pose networks supports setup recovery as a reusable interface between interchangeable sensors and pretrained pose models.
Figures & tables
Figure 2: Overview of MOSAIC. (a) The input consists of six IMU streams with unknown anatomical assignments and mounting rotations. (b) A shared encoder alternates temporal and cross-sensor attention to extract window-level assignment scores and mounting evidence. These outputs accumulate across the session. Hungarian matching and projection onto SO(3) recover the assignment and mounting rotations, respectively. (c) The estimated setup canonicalizes the measurements for a frozen pose network, such as LSTM, PIP or DynaIP [ 23 , 27 ] . Green and gray meshes denote predicted and reference poses, respectively.
DIP-IMU
TotalCapture
Method
SIP ( ∘ )
Ang ( ∘ )
Pos (cm)
Mesh (cm)
Jitter (km/s 3 )
SIP ( ∘ )
Ang ( ∘ )
Pos (cm)
Mesh (cm)
Jitter (km/s 3 )
Calibrated input †
16.5
9.7
5.4
6.4
2.18
12.7
11.7
5.2
6.0
3.85
Bounded mounting ( θmax=30∘ )
No estimate
67.2
63.6
28.5
34.4
3.72
62.0
59.7
27.0
33.2
5.35
No calibration †
28.6
23.0
10.8
12.7
2.50
23.1
22.4
10.5
12.3
4.26
TIC [ 31 ] , retrained †
26.7
21.2
9.9
11.6
2.41
17.8
16.8
7.8
9.0
4.00
Table 1: Pose accuracy under unknown setup. Results are averaged over recordings. Per take resets setup evidence at each recording; per session retains it across recordings. † True sensor-to-segment assignments are available. The calibrated-input reference uses dataset-provided calibrated measurements without additional setup transformations. Lower is better for all metrics.
Network
Input
SIP ( ∘ )
Ang ( ∘ )
Pos (cm)
DIP-IMU
PIP
Calibrated input
15.4
8.5
4.8
Ours ( θmax=30∘ )
15.8
10.3
5.0
Ours (arbitrary)
17.5
12.6
5.6
DynaIP
Calibrated input
14.9
7.2
4.7
Ours ( θmax=30∘ )
15.1
9.8
5.1
Table 2: Compatibility with advanced pose networks. PIP uses pose predictions before physics-based optimization; DynaIP follows the default poser’s training data and schedule.
Figure 3: Qualitative comparison of temporal pose reconstructions in a TotalCapture session. Rows show ground truth, the frozen LSTM poser with calibrated input, and MOSAIC with the same poser under bounded ( θmax=30∘ ) and arbitrary mountings.
Mounting
Dataset
tassignmax (s)
t15∘ (s)
Calib. error ( ∘ )
θmax=30∘
DIP-IMU
2
1
6.2
θmax=30∘
TotalCapture
2
1
7.8
Arbitrary
DIP-IMU
8
8
14.2
Arbitrary
TotalCapture
4
4
12.1
Table 3: Online setup recovery. tassignmax is the maximum time across evaluated sessions until all six sensor-to-segment assignments become correct and remain correct thereafter. t15∘ is the median time to first achieve correct assignment and mean mounting error below 15∘ ; all evaluated sessions reach this threshold. Calib. error denotes the mounting rotation error at 10 s, averaged over sensors and sessions.
Strategy
DIP-IMU
TotalCapture
Bounded mounting ( θmax=30∘ )
Last window
18.0
14.8
Non-overlapping
16.8
13.7
Rotation pooling
16.8
13.7
Evidence pooling (ours)
16.8
13.6
Arbitrary mounting
Table 4: Ablation of temporal evidence accumulation. Per-session SIP error ( ∘ ) with fixed networks and identical input recordings. Best results within each mounting regime are bold.
DIP-IMU
TotalCapture
Assignment
Mounting
SIP ( ∘ )
Ang ( ∘ )
SIP ( ∘ )
Ang ( ∘ )
Bounded mounting ( θmax=30∘ )
Estimated
Estimated
16.8
11.2
13.6
12.9
GT
Estimated
16.8
11.2
13.6
12.9
Estimated
GT
16.5
9.7
12.7
11.7
Arbitrary mounting
Table 5: Ablation of setup errors. Per-session pose errors with ground-truth (GT) assignment, mounting, or both.
Figure 4: Angular-error gap to the calibrated-input reference over time. Per-session differences in ground-truth-referenced angular error are computed against calibrated inputs at matching frames and averaged across subjects and sensor configurations at 40 uniformly sampled times over the first four minutes. The dashed zero line marks calibrated accuracy.
Figure 5: Per-segment mounting recovery for arbitrary orientations, per session. Stacked twist/swing errors at 5 s and 10 s after session start, and temporal means over the remainder after 10 s and 1 min. Temporal means are computed within sessions before averaging across subjects and sensor configurations.
Figure 6: Live demo. Video frames and corresponding SMPL reconstructions using six IMUs with unknown sensor-to-segment assignments and arbitrary mounting orientations.
Appendix figures & tables4 assets
Supplementary material from the paper’s appendix.
Appendix
Mounting
Stage
Data
Iterations
Batch size
Learning rate
θmax=30∘
Single-window pretraining
AMASS
30,000
64
3×10−4
Accumulation training
Mixed
8,000
16
10−4
Arbitrary
Single-window pretraining
AMASS
30,000
64
3×10−4
Single-window fine-tuning
Mixed
6,000
64
10−4
Accumulation training (confidence only)
Mixed
3,000
16
10−3
Appendix
Table 6: Training schedule for MOSAIC. Mixed data combines AMASS and DIP-IMU subjects 1–8 in equal proportions.
Experiment
Condition
DIP-IMU
TotalCapture
Mounting range
θmax=15∘
16.7
13.3
θmax=30∘
16.8
13.6
θmax=45∘
17.6
14.7
θmax=60∘
20.1
18.1
θmax=180∘
66.6
65.0
Re-attachment
Unchanged, detector off
19.2
14.2
Appendix
Table 7: Extended robustness results. All entries are per-session SIP errors in degrees. The range test uses the model trained with θmax=30∘ . The re-attachment test uses the separately trained arbitrary-mounting model.
Trial
tassign (s)
SIP ( ∘ )
Ang ( ∘ )
Pos (cm)
Mesh (cm)
Jitter (km/s 3 )
1
6
21.1
20.3
8.0
10.3
1.30
2
7
22.7
22.8
9.2
11.8
1.71
3
1
23.4
23.6
8.9
11.2
2.09
Mean
4.7
22.4
22.2
8.7
11.1
1.70
Appendix
Table 8: Quantitative results on our collected IMU recordings. Pose errors are measured against the GVHMR visual reference. tassign denotes the time until all six assignments become correct and remain correct thereafter.
Figure 7: Qualitative comparisons on our collected IMU recordings. GVHMR provides the offline visual reference. Calibrated input uses known sensor assignments and mounting rotations derived from the initial visual pose and IMU readings, with camera-to-IMU heading alignment estimated from the first 10 s.
The University of New South Wales · The Hong Kong University of Science and Technology (Guangzhou) · The Hong Kong University of Science and Technology