cs.LGNov 17, 2026

EEG2MCU: Sensing-to-Execution Co-Design for Wearable EEG Inference

Authors: Shoma Yukawa, Meghna Roychowdhury, Arnab Sanyal, Chengwei Zhou, Shreyas Sen, Gourav Datta

Organizations: Case Western Reserve University, Cleveland, OH · Purdue University, West Lafayette, IN · The University of Texas, Austin, TX

Abstract

Wearable EEG inference is constrained not only by model size, but also by the channel-dependent sensing front end that must process high-dimensional inputs before compact downstream computation. We present EEG2MCU, a sensing-to-execution co-design framework that treats electrode count as a hardware design variable through task-aware montage selection. EEG2MCU retains a compact time-frequency representation and generates only the INT8 regions required by each first-layer tile, avoiding full input materialization. Halo reuse and access-aware placement across Flash, SRAM, and tightly coupled memory further reduce redundant generation and data movement. On a Cortex-M7 MCU, EEG2MCU reduces peak SRAM by 11.38x relative to the baseline, including a 1.71x reduction from the 62-to-19 electrode montage, while reducing latency by 2.57x and energy by 2.48x. It retains 94-96% of full-montage accuracy, demonstrating practical high-dimensional EEG inference under tight embedded-resource constraints.

Figures & tables

Explore similar work

Sep 10, 2026

BRIDGE-EEG: Bridging Self-Supervised Pretraining and Efficient Deployment for Cross-Dataset EEG Classification

The growing use of electroencephalography (EEG) motivates automated analysis that is accurate, transferable, and deployable on constrained hardware. Recent EEG foundation models learn general representations from large-scale pretraining, but their size and computational cost limit edge and wearable deployment. We introduce BRIDGE-EEG, an efficient multi-task EEG classification pipeline that preserves the benefits of pretraining while reducing model size. A unified preprocessing scheme maps heterogeneous recordings with different channel counts, montages, and sampling rates to a device-agnostic 62-channel time--frequency representation. We pretrain an SE-ResNet18 teacher (11.84 M parameters) with SimCLR on unlabeled EEG from five heterogeneous datasets, then compress it into SE-ResNet8 (1.56 M) and SE-ResNet4 (0.48 M) students using task-agnostic and task-specific distillation. We evaluate six benchmarks spanning abnormality detection, motor imagery, and emotion recognition. For abnormality detection and emotion recognition, the students achieve accuracy comparable to or better than several recent EEG foundation models with 10--1,000×\times more parameters. Motor imagery shows a remaining representation gap, highlighting the importance of pretraining diversity. Inference profiling on a server GPU, desktop CPU, and NVIDIA Jetson Orin Nano shows up to 3.0×\times lower edge energy per inference (15.64 mJ vs. 46.67 mJ). The compact models further support future deployment on MCU-class wearables.
Oct 21, 2026

BrainCodes: A Lightweight EEG Foundation Model over Discrete Neural Codes

Recent electroencephalography (EEG) foundation models increasingly emphasize model scale, potentially limiting their deployment on resource-constrained devices and in everyday environments. We argue that transferable EEG features can instead be learned with a compact architecture and introduce BrainCodes, a lightweight foundation model pretrained through self-supervised learning on more than 800 hours of recordings from over 1,000 participants. Our architecture combines a quantization-based neural tokenizer with a spatiotemporal encoder that supports arbitrary electrode configurations. The pretraining objective explicitly encourages representations that capture spatial connectivity through channel positional encoding, and sensitivity to narrowband neural oscillations through an auxiliary training objective. Our model matches or surpasses the state of the art across diverse neurophysiological monitoring tasks, including sleep staging, attention assessment, and cognitive load estimation. BrainCodes transfers effectively to low-resource wearable devices while using up to 97% fewer trainable parameters than comparable architectures. Beyond predictive accuracy, our evaluation framework characterizes the geometry and invariances of learned EEG representations across measurable spatial, temporal, and spectral signal properties.
Apr 20, 2026

Towards Real-Time ECG and EMG Modeling on μμNPUs

The miniaturisation of neural processing units (NPUs) and other low-power accelerators has enabled their integration into microcontroller-scale wearable hardware, supporting near-real-time, offline, and privacy-preserving inference. Yet physiological signal analysis has remained infeasible on such hardware; recent Transformer-based models show state-of-the-art performance but are prohibitively large for resource- and power-constrained hardware and incompatible with μμNPUs due to their dynamic attention operations. We introduce PhysioLite, a lightweight, NPU-compatible model architecture and training framework for ECG/EMG signal analysis. Using learnable wavelet filter banks, CPU-offloaded positional encoding, and hardware-aware layer design, PhysioLite reaches performance comparable to state-of-the-art Transformer-based foundation models on ECG and EMG benchmarks, while being <10% of the size (∼\sim370KB with 8-bit quantization). We also profile its component-wise latency and resource consumption on both the MAX78000 and HX6538 WE2 μμNPUs, demonstrating its viability for signal analysis on constrained, battery-powered hardware. We release our model(s) and training framework at: https://github.com/j0shmillar/physiolite.