physics.med-phNov 18, 2026

Geometry-bridge flow matching for blind rigid-motion correction in head cone-beam CT

Authors: Sungho Yun, Seungryong Cho

Organizations: Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, South Korea

Abstract

Rigid motion of a patient head during head cone-beam CT (CBCT) scan can degrade image quality and complicate recovery of accurate anatomical structures from the measured projections. We present a 3D flow-matching prior approach that learns the image changes induced by motion. Its geometry-bridge connects motion-corrupted and motion-free Feldkamp-Davis-Kress (FDK) reconstructed images of the same source volume through progressively reduced simulated motion. The forward projector's geometry derivative supplies analytic velocity targets along this path. A plug-and-play loop encompasses the learned image updates together with spline-based pose estimation, conjugate-gradient data consistency, and image total-variation regularization. Both the refined image volume and the FDK reconstructed image volume at the estimated poses are evaluated. On simulated 360-view scans from 30 held-out CQ500 patients with nominal per-component motion amplitudes within 10 mm / 10 degrees, the framework achieved state-of-the-art image reconstruction quality and motion accuracy in comparison with other methos such as learned autofocus and diffusion-based joint reconstruction. Mean peak signal-to-noise ratio (PSNR) reached 37.1 dB and mean detector-plane reprojection error (RPE) was 0.27 mm. With matched endpoints at the inference settings, the geometry bridge improved PSNR by 1.6 dB and reduced RPE by 33% relative to image-linear training. With 50 prior updates and coarse-to-fine motion estimation, total processing time averaged 9.1 minutes per patient on an RTX A6000.

Figures & tables

Explore similar work

Feb 28, 2026

RAFM: Retrieval-Augmented Flow Matching for Unpaired CBCT-to-CT Translation

Cone-beam CT (CBCT) is routinely acquired in radiotherapy but suffers from severe artifacts and unreliable Hounsfield Unit (HU) values, limiting its direct use for dose calculation. Synthetic CT (sCT) generation from CBCT is therefore an important task, yet paired CBCT--CT data are often unavailable or unreliable due to temporal gaps, anatomical variation, and registration errors. In this work, we introduce rectified flow (RF) into unpaired CBCT-to-CT translation in medical imaging. Although RF is theoretically compatible with unpaired learning through distribution-level coupling and deterministic transport, its practical effectiveness under small medical datasets and limited batch sizes remains underexplored. Direct application with random or batch-local pseudo pairing can produce unstable supervision due to semantically mismatched endpoint samples. To address this challenge, we propose Retrieval-Augmented Flow Matching (RAFM), which adapts RF to the medical setting by constructing retrieval-guided pseudo pairs using a frozen DINOv3 encoder and a global CT memory bank. This strategy improves empirical coupling quality and stabilizes unpaired flow-based training. Experiments on SynthRAD2023 under a strict subject-level true-unpaired protocol show that RAFM outperforms existing methods across FID, MAE, SSIM, PSNR, and SegScore. The code is available at https://github.com/HiLab-git/RAFM.git.
Sep 1, 2026

ReBridge-Flow: Re-Coupling Posterior Bridges in Flow Matching for Image Restoration

Flow Matching provides an efficient generative prior for image restoration by learning continuous transport between source and data distributions. However, existing methods typically incorporate measurement constraints through local corrections. Such corrections may disrupt the source-clean endpoint coupling implicitly encoded by the pretrained flow, making the corrected endpoint pair incompatible with the current state. To address this issue, we propose ReBridge-Flow, a posterior bridge re-coupling method. Specifically, given the current state, ReBridge-Flow first decodes the corresponding local source and clean endpoints. It then incorporates measurement information through clean-side anchoring and synchronously re-couples the source endpoint, yielding a measurement-aware endpoint pair with improved local bridge compatibility. The re-coupled endpoints further define a posterior-informed transport direction for advancing the sampling process. We also introduce the Posterior Bridge Defect, which jointly characterizes measurement error, deviation from the flow prior, and bridge mismatch, and leads to explicit updates for clean-side anchoring and source-side re-coupling. Extensive experiments on multiple natural and medical image restoration tasks demonstrate that ReBridge-Flow effectively alleviates bridge mismatch and improves the structural consistency of restored images.
Oct 29, 2026

FFAI: Flow Matching with Feedback Training and Adaptive Initialization for CT Reconstruction

Although low-dose, sparse-view, and limited-angle CT involve distinct degradation mechanisms, all three pose reconstruction challenges due to limited measurement information and can therefore be addressed within a unified framework. In iterative image restoration with flow matching, prediction errors may cause inference states to deviate from the prescribed training path, while a fixed initialization may be unsuitable for inputs with varying degradation severity. We propose a unified conditional flow matching method that conditions on the initial reconstruction and combines feedback-aware training with degradation-adaptive initialization. During training, a teacher network simulates inference updates to generate shifted states, from which a student network learns to recover high-quality reference images, improving its ability to handle prediction errors. During inference, the starting time is selected based on the noise level or extent of missing projection data, and the noise added to the initial state is adjusted accordingly to adapt the starting point to the input. Experiments on public benchmark datasets show that the proposed method achieves better quantitative results than the compared methods across all three reconstruction tasks, effectively suppressing noise and artifacts while preserving anatomical structures and details.