Organizations: The authors are with the Department of Mechano-Informatics, Graduate School of Information Science and Technology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656, Japan.
Tendon-driven robots, which actuate like biological muscles by using motors to wind wires, offer advantages such as variable stiffness and redundant actuation. Despite these advantages, musculoskeletal structures inherently involve a large number of diverse muscles, making it desirable to compactly modularize each muscle unit and flexibly accommodate diverse muscle arrangements. While various small muscle modules have been proposed to date, existing designs tend to be complex, difficult to maintain, and suffer from low backdrivability and limited actuation speed due to their high gear ratios. In this work, we propose QDD-MM, a muscle module that leverages recent advances in quasi-direct-drive motors to achieve a simpler and more compact structure with higher backdrivability and faster actuation than previous modules. By utilizing quasi-direct-drive motors, the module eliminates the need for dedicated force-sensing mechanisms, significantly simplifying the overall design, while also supporting flexible wire routing in multiple directions, various module-to-module connections, and even the use of the module body itself as a structural component. QDD-MM integrates these capabilities into a reusable muscle module, and its design is openly available at https://github.com/haraduka/qddmm. We developed tendon-driven robots with one joint and either two or three muscles, as well as a partial musculoskeletal humanoid, using the proposed QDD-MM and verified their effectiveness. We expect that this muscle module will democratize tendon-driven robotics and further accelerate progress in the field.
Figures & tables
Fig. 1: The concept of QDD-MM: a compact muscle module (left) and configurable tendon-driven mechanisms (middle). The full humanoid (right) illustrates the intended application.
Fig. 2: Design overview of QDD-MM: the muscle module consists of a main body integrating a quasi-direct-drive motor and pulley system, and a detachable wire routing unit that defines the wire’s pulling direction.
Fig. 3: All components of QDD-MM consisting of muscle module parts, which constitute the muscle module, and module connectors, which link these modules together.
Fig. 4: Wire connection method to the Motor-Pulley: the wire end is tied, and then passed alternately through seven small pulleys in a weaving manner, allowing the wire to be secured by friction.
Fig. 5: Various wire routing directions: by changing the orientation of the wire routing unit, the wire can be routed forward, backward, leftward, rightward, or upward.
Fig. 6: The four module connectors have interlocking convex and concave structures, enabling connection between modules in five directions: forward, backward, leftward, rightward, and downward.
Fig. 7: Various connections between muscle modules: two muscle modules can be connected to each other to the right, left, and downward using two types of module connectors, and to the front and back using the other two types of module connectors.
Fig. 8: Conventional muscle modules: composed of an elongated motor with a high gear ratio and pulley, a tension measurement unit, a motor driver, and their protective covers.
Fig. 9: The relationship between the muscle length displacement and muscle tension for the previous muscle module [ 14 ] (Previous) and QDD-MM.
Fig. 10: The relationship between the commanded and measured muscle tensions for the previous muscle module [ 14 ] (Previous) and QDD-MM.
Fig. 11: Experimental setup: the left panel shows a configuration with two muscles attached to the bone frame, the middle panel shows a configuration with three muscles realized by adding a module in parallel, and the right panel shows a series connection in which the module itself is used as the bone frame.
Fig. 12: The experimental results corresponding to Fig. 11 , including the commanded and measured joint angles as well as the measured muscle tensions.
Fig. 13: Shoulder–arm prototype driven by eight externally mounted QDD-MMs. Left: module arrangement and musculoskeletal structure. Right, (1)–(3): successive postures showing the change in upper-arm orientation and shoulder configuration relative to the torso.
Fully-powered knee prostheses, unlike traditional passive knees, can perform controlled positive work, reducing the need for compensatory behaviors by users during energy-intensive activities. While quasi-direct drive (QDD) actuators provide superior torque control, backdrivability, and acoustic noise properties compared to traditional highly-geared actuators, prior QDD prototypes have been too heavy and bulky for commercial translation. In this work, we present the design and validation of a new lightweight (2.6 kg) and low-profile (24.5 cm tip-to-tip build height) QDD knee prosthesis. By optimizing an 18 to 1 two-stage transmission alongside thermal and structural finite-element analyses, we significantly reduce device mass while enabling a peak torque of 145 Nm. Through benchtop tests, we validate the device's high output torque, low backdrive torque (1 Nm), and its precision position and torque control capabilities. We also demonstrate biomimetic kinematics and peak knee extension torques (within one standard deviation of able-bodied references) during both level-ground walking and sit-stand transitions performed by three participants with transfemoral amputation and varying K-levels. By meeting or improving upon the mass, build height, peak torque, and acoustic noise of a leading commercial powered knee, this work establishes the clinical viability of emerging QDD prostheses that promise improved dynamic performance for their users.
Ross J. Cortino, Ryan Posh, Emily G. Keller +1
Robotics Department, University of Michigan, Ann Arbor, MI 48109
Selecting an appropriate motor-gearbox combination is a critical design task in robotics because it directly affects cost, mass, and dynamic performance. This process is especially challenging in modular robots with closed kinematic chains, where joint torques are coupled and actuator inertia propagates through the mechanism. We present Robodimm, a software framework for automated actuator sizing in scalable robot architectures. By leveraging Pinocchio for dynamics and Pink for inverse kinematics, Robodimm uses a Karush-Kuhn-Tucker (KKT) formulation for constrained inverse dynamics. The platform supports parametric scaling, interactive trajectory programming through jog modes, and a two-round validation workflow that addresses actuator self-weight effects.
J. L. Torres, M. Munoz, J. D. Alvarez +2
CIESOL-ceiA3, Department of Engineering, University of Almería, Spain · CIESOL-ceiA3, Department of Computer Science, University of Almería, Spain
Forward kinetostatics of spatial tendon-driven continuum robots typically requires a nonlinear equilibrium solve for each actuation input. This paper develops a force-to-Cartesian-configuration model with a closed-form solution in quadratures for spatial multi-segment robots under tendon actuation. The Cartesian backbone centerline and accumulated material twist serve as generalized coordinates, from which the strain measures and tendon geometry are derived. Variational equilibrium yields explicit axial and bending relations and establishes zero equilibrium material twist within the proposed model for admissible longitudinal non-helical routing. The solution is propagated segment by segment without an iterative equilibrium solve, while retaining axial deformation, spatially varying axial and bending stiffnesses and tendon-routing diameter, and segment-dependent tendon participation. Numerical comparisons with a full-strain geometric variable-strain model (GVS) yield maximum length-normalized tip-position discrepancies of 8.91 x 10^-6 and 1.01 x 10^-5 for the single- and three-segment robots, respectively. Mean evaluation times of 1.52 μs and 2.94 μs, with corresponding speedups of approximately 1864x and 3348x over the baseline, demonstrate the computational advantage of the explicit force-to-configuration mapping in the reported benchmark.