Training-free diffusion priors are powerful for inverse problems, but measurement guidance during reverse sampling is local: aggressive updates can improve immediate data fit while disrupting later denoising. We introduce an anchored inertial correction rule that separates proposal generation from acceptance. At each corrected step, the denoiser prediction anchors a frozen clean-space objective combining measurement fit with a noise-level-dependent proximal term. Heavy-ball dynamics with step size and momentum computed from the measured curvature generate a clean-state candidate; a separate verifier evaluates it with the same objective, with the denoiser prediction retained as fallback; both stages are derived from one objective for the whole trajectory, considered one step at a time. The accepted clean state is re-noised to continue sampling. The rule applies to pixel and latent diffusion with differentiable measurement operators, requires no retraining, and adds no denoiser calls inside the correction loop. We analyze how objective verification yields local nonincrease and displacement control. Across natural-image benchmarks, the method achieves competitive reconstruction quality. Code is available at https://github.com/Seunghyeok0715/PIVOT2026.
Figures & tables
Figure 1: Representative reconstructions. Qualitative comparison on pixel-space random inpainting and Phase retrieval, and latent-space motion and nonlinear deblurring. Red boxes show zoomed regions. Metrics are per-image PSNR ↑ , LPIPS ↓ , and sampling time ↓ . PIVOT preserves sharper details with favorable speed–quality trade–offs.
Figure 2: PIVOT overview. (a) The denoiser prediction μk anchors a frozen clean-space objective Φk combining measurement fidelity with a noise-dependent proximal term. (b) Starting from μk , heavy-ball (HB) updates combine data and proximal term gradients with inertia; step size and momentum are computed from the proximal term curvature and guarded data-gradient secant estimates. (c) The final HB iterate is accepted only if it lowers the same frozen objective relative to μk ; otherwise, the anchor is retained, ensuring Φk(zk+)≤Φk(μk) . (d) Fresh Gaussian noise at the next scheduled noise level is added to the selected clean state to continue reverse diffusion. The same procedure applies in pixel or latent space without additional denoiser evaluations inside the correction loop.
Method
×4
×8
PSNR ( ↑ )
SSIM ( ↑ )
PSNR ( ↑ )
SSIM ( ↑ )
Ours
29.17
0.650
27.87
0.589
DPS
25.82
0.548
22.99
0.507
DAPS
28.55
0.690
27.04
0.630
DDS
28.52
0.678
25.84
0.593
FAST-DIPS
28.79
0.607
27.36
0.545
Table 2: Quantitative evaluation for MRI reconstruction under random-disc undersampling at acceleration factors ×4 and ×8 . We report average PSNR/SSIM over 96 test samples. Best scores are in bold and second-best are underlined .
Figure 3: Qualitative comparison for ×8 accelerated multi-coil fastMRI knee reconstruction. Each column shows the target image and the reconstruction from a different diffusion based method, with the corresponding PSNR reported in the image.
Appendix figures & tables15 assets
Supplementary material from the paper’s appendix.
Appendix
Task
K
J
Pixel-space
Super resolution 4×
40
15
Inpaint (box)
90
15
Inpaint (random)
100
15
Gaussian deblurring
20
140
Motion deblurring
40
20
Appendix
Table 3: Task-specific settings for pixel-space and latent-space PIVOT . Here, K denotes the number of reverse diffusion steps and J denotes the number of gradient evaluations per step ( J−1 heavy-ball steps); each value is shared by FFHQ and ImageNet.
Param (DCDP)
SR
BIP
RIP
GB
MB
tk
100
100
100
100
100
α
102
103
103
105
105
Appendix
Table 4: DCDP hyperparameters for noisy linear tasks.
Param (PSLD)
SR
BIP
RIP
GB
MB
η
1.0
0.1
0.1
0.1
0.1
γ
0.1
10−3
10−2
10−3
10−2
Appendix
Table 5: PSLD hyperparameters used in our experiments.
Variant
ImageNet latent 4× SR
FFHQ pixel phase retrieval
PSNR ↑
SSIM ↑
LPIPS ↓
PSNR ↑
SSIM ↑
LPIPS ↓
Full PIVOT
27.364
0.744
0.384
31.572
0.886
0.197
Gradient proposal
26.291
0.695
0.438
27.391
0.807
0.270
Without curvature decay
27.126
0.733
0.396
31.869
0.890
0.193
Polyak first step
26.779
0.731
0.403
30.949
0.878
0.201
Without final verification
27.364
0.744
0.384
31.572
0.886
0.197
Appendix
Table 6: Component ablation of PIVOT . Each variant modifies a single design choice. Results are averaged over 30 images per task, with phase retrieval following the best-of-four protocol.
Figure 4: Speed–quality trade-off. Quality metrics versus runtime as the PIVOT budget K×J is varied. Each point represents an average over 100 samples. Baselines are shown as fixed operating points.
Task
K
J
K×J
Random inpainting (FFHQ pixel)
20
10
200
30
10
300
40
10
400
56
10
560
80
20
1600
80
160
12800
Appendix
Table 7: PIVOT budgets used in the speed–quality study.
Method
Super resolution 4×
Nonlinear deblurring
PIVOT
0.613
1.045
FAST-DIPS
0.614
1.050
DAPS
0.626
1.063
SITCOM
2.036
2.593
DMPlug
5.236
5.793
DCDP
0.723
1.155
Appendix
Table 8: Per-sample peak allocated GPU memory (GiB) during pixel-space sampling for super resolution 4× and nonlinear deblurring, averaged over 20 FFHQ samples. Results were obtained on a single RTX 6000 Ada GPU with a batch size of 1.
Figure 5: Qualitative results for 4× super resolution on FFHQ and ImageNet.
Figure 6: Qualitative results for box-mask inpainting on FFHQ and ImageNet.
Figure 7: Qualitative results for random-mask inpainting on FFHQ and ImageNet.
Figure 8: Qualitative results for Gaussian deblurring on FFHQ and ImageNet.
Figure 9: Qualitative results for motion deblurring on FFHQ and ImageNet.
Figure 10: Qualitative results for nonlinear deblurring on FFHQ and ImageNet.
Figure 11: Qualitative results for high dynamic range recovery on FFHQ and ImageNet.
Figure 12: Qualitative results for phase retrieval on FFHQ and ImageNet. For each input, we report reconstructions from four independent trials.