Splice-Core is a temporal-unary/binary (tub) hybrid general matrix multiplication (GEMM) unit that minimizes low-order accumulation latency, while retaining value-dependent execution for high-order activation bits. We present two novel processing element (PE) variants: (i) Splice-BP utilizing bit planes, and (ii) Splice-LUT, which selects a shared weight multiple in a single cycle. Compared to a binary systolic array, Splice-BP/Splice-LUT achieve 77.4%/76.4% geometric-mean tile energy reductions, respectively, across 26 INT4 convolutional neural network (CNN) and large language model (LLM) workloads in 45nm. Splice-LUT further increases geometric-mean tile throughput by 44.4% and reduces geometric-mean energy-delay product (EDP) by 6.13x across the 26 configurations. Across the evaluated W8A8 convolution and expert-projection workloads, Splice-BP and Splice-LUT reduce tile energy by 77.3-88.1%. Post-place-and-route INT4 yields 14%/9% smaller area for Splice-BP/Splice-LUT, compared to the systolic array.
Figures & tables
Fig. 1: Splice-Core microarchitecture. (a) PE array with per-column weight-multiple generation and per-row broadcast of temporal control signals. (b) Splice-BP and Splice-LUT low-order datapaths and their common high-order accumulation datapath. (c) Temporal encoder generating low-order selection and high-order unary control signals. (d) Illustrating lower-order-bit-splicing for Splice-BP and Splice-LUT.
Tile
Design
Cell area (mm 2 )
Power (mW)
Cycles/tile
163
Systolic
0.1254
32.46
48
Splice-BP
0.1141
7.16
49–50.5
Splice-LUT
0.1183
10.87
33–34.5
323
Systolic
0.5152
128.45
96
Splice-BP
0.4408
28.28
97–106.75
Splice-LUT
0.4711
44.22
65–74.75
TABLE I: INT4 post-synthesis area, power, and cycles at 400 MHz. Power is the geometric mean of per-case mean total power. Cycle ranges span the mean tile cycle counts across workloads.
Fig. 2: INT4 tile energy and throughput at 400 MHz across 26 workload configurations. Both metrics are normalized to the systolic array. MV2, MV3, and R50 denote MobileNetV2, MobileNetV3, and ResNet-50. B denotes request batch size.
Design
Cell area
Power
Cycles
Energy
Throughput
(mm 2 )
(mW)
per tile
(nJ)
(GOPS)
ResNet-50 convolution
Splice-BP
0.5023
36.64
134.38
12.31
195.08
Splice-LUT
0.5260
64.20
78.33
12.57
334.65
Systolic
0.7803
231.28
96.00
55.51
273.07
OLMoE top-8 expert projection
TABLE II: INT8 post-synthesis results for 323 tiles at 400 MHz. Throughput counts two operations per MAC over padded tile.
Design
Venue
Process
Precision
Geometry
Clock
Scope
Area
Power
Energy
Throughput
(MHz)
(mm 2 )
(mW)
(nJ/tile)
(GOPS)
4-bit results
tubGEMM [ 9 ]
ISVLSI 2024
Nangate45
4-bit
32×32
400
Worst-case synth.
0.1519
39.1
12.51
204.80 d
Cambricon-C [ 27 ]
MICRO 2024
FreePDK45
W4A4
32×32
400
SA + converter
12.23
1879.36
–
–
This work: Qwen B1, 323 tiles
Systolic
–
Nangate45
W4A4
32×32
400
Array synth.
0.5152
130.09
31.221
273.07
TABLE III: Comparison of GEMM implementations across precision, technology, and evaluation scope.
MHz
Design
Area
Power
Latency
Energy
Slack
(mm 2 )
(mW)
(ns)
(nJ)
(ps)
400
Systolic
0.12540
32.966
120.000
3.956
8
Splice-BP
0.11412
7.308
122.695
0.897
0
Splice-LUT
0.11831
10.746
82.695
0.889
0
1000
Systolic
0.14211
79.716
48.000
3.826
1
Splice-BP
0.14260
21.783
49.078
1.069
0
TABLE IV: INT4 synthesis at two clock targets for Qwen MoE batch-1 decode ( 163 tiles). Slack is rounded to the nearest picosecond.
Design
Workload
Routed area
ΔA
Setup
Hold
Power
Energy
Throughput
(mm 2 )
(%)
(ps)
(ps)
(mW)
(nJ/tile)
(GOPS)
Splice-BP
OPT B1
0.439211
−0.36
0
+33
19.30
3.78
270.25
Llama prefill
18.65
35.49
245.57
Splice-LUT
OPT B1
0.467178
−0.84
+23
+19
27.64
3.84
403.30
Llama prefill
25.66
38.22
350.69
Systolic
OPT B1
0.513112
−0.41
−5
+6
103.71
31.15
273.07
TABLE V: INT4 P&R results and workload metrics for 323 tiles at 400 MHz. ΔA is the cell-area change from synthesis to routing. Area and worst setup and hold slack apply to both workloads within each design.