cs.CVNov 20, 2026

Learning 3D MRI Representations with Generative Adversarial Networks

Authors: Sujeet Lahane, Sapna Mishra, Akash Suryavanshi, Tapan Gandhi, Bharat Biswal

Organizations: Department of Mechanical Engineering, IIT Delhi, New Delhi, 110016 India · Department of Computer Science, IIT Delhi, New Delhi, 110016 India · Department of Electrical Engineering, IIT Delhi, New Delhi, 110016 India · Department of Biomedical Engineering, NJIT, Newark, NJ 07102 USA

Abstract

Learning representations of visual images is a challenging task. It requires extracting abstract patterns from high-dimensional data without explicit supervision. This becomes pronounced with 3D MR imaging due to sparse features, higher dimensional inputs, and smaller datasets. Many state-of-the-art representation learning algorithms successfully rely on transformers and diffusion-based architectures. However, these methods struggle with smaller datasets. In effect, solution methods relax the problem by slicing 3D volumes and solving the problem for 2D medical imaging, resulting in a loss of spatial 3D information. We present R2RG, a representation learning method based on Convolutional Neural Networks (CNNs), with Generative Adversarial Networks (GANs) honing the reconstruction task. Our key insights lie in exploiting architectural biases in 3D CNNs, combined with data-efficient auto-encoding GANs and a composite loss function to enhance reconstruction fidelity and stabilize training. Our experiments on three standard datasets and a locally collected dataset show that R2RG not only achieves superior performance but also generalizes to heterogeneous and smaller datasets. Furthermore, representations learned with R2RG outperform those learned with contrastive-based representation learning methods on Parkinson's and Alzheimer's disease classification. Our work demonstrates that reconstruction-based representation learning is a promising direction for 3D medical imaging under limited data availability.

Figures & tables

Explore similar work

Nov 4, 2026

Representation Learning for 3D Brain Imaging: A Benchmark

Many deep learning architectures for computer vision tasks rely on features extracted by a pre-trained encoder on large databases of natural 2D RGB images. However, the wide domain gap with medical images hampers the direct transfer of optimized deep learning models from computer vision to clinical applications. Recently, self-supervised pre-training and foundation models emerged as promising alternatives to mitigate these limitations. Yet, constructing such models for medical imaging faces critical challenges, including designing and adapting training strategies for large 3D volume datasets, and the need for standardized benchmarks to evaluate feature extraction performance. In this study, we propose an extensive comparison of vision encoders with a focus on 3D brain MRI. First, we consider 8 fully and self-supervised models pretrained on natural images (e.g. ResNet, DINO, CLIP) and 10 backbone architectures trained on medical images, either based on supervised (e.g. RadImageNet) or self-supervised (e.g. BiomedCLIP, SimCLR) tasks. All pre-trained encoders are evaluated on various downstream tasks to assess the representation power of their latent representations, including age and sex prediction as well as disease classification on the ADNI and PPMI datasets. Our study shows that 2D encoders pre-trained on natural images perform the most favorably, even compared to models pre-trained on more than 100k brain MRI volumes, highlighting the need for more suitable and robust methods for representation learning in 3D medical imaging. The source code for this study is publicly available at: https: //github.com/PierreFalconnier/brain-representation-benchmark.
Jul 15, 2026

TCAM-Diff: Triplane-Aware Cross-Attention Medical Diffusion Model

We introduce TCAM-Diff, a novel 3D medical image generation model that reduces the memory requirements to encode and generate high-resolution 3D data. This model utilizes a decoder-only autoencoder method to learn triplane representation from dense volume and leverages generalization operations to prevent overfitting. Subsequently, it uses a triplane-aware cross-attention diffusion model to learn and integrate these features effectively. Furthermore, the features generated by the diffusion model can be rapidly transformed into 3D volumes using a pre-trained decoder module. Our experiments on three different scales of medical datasets, BrainTumour 128 x 128 x 128, Pancreas 256 x 256 x 256, and Colon 512 x 512 x 512, demonstrate outstanding results. We utilized MSE and SSIM to assess reconstruction quality and leveraged the Wasserstein Generative Adversarial Network (W-GAN) critic to assess generative quality. Comparisons with existing approaches show that our method gives better reconstruction and generation results than other encoder-decoder methods with similar-sized latent spaces.
Oct 19, 2026

3D Diffusion Models for Medical Imaging

Generative deep learning methods such as Variational Autoencoders, Generative Adversarial Networks or Diffusion Models have achieved remarkable results in image synthesis. In particular, Diffusion Models have demonstrated superior image fidelity and sample diversity compared to other approaches on standard benchmarks, while also offering more flexible training dynamics as evidenced both in natural image domains and in medical applications. In medical imaging including Computed Tomography, Magnetic Resonance Imaging or Positron Emission Tomography, such models have various important use-cases including data augmentation, domain transfer, image reconstruction, inpainting, image augmentation and artifact correction. Further, generated images can be conditioned on patient characteristics, medical reports, segmentation masks or other images. Specific challenges arise due to the 3D volumetric nature of medical images, which translate to substantial demands in terms of memory, compute, and training data. This article provides a comparative overview of 3D Diffusion Models which have been developed for medical images, with a focus on current performance, limitations, and an outlook for future work.