Multi-modal image fusion is crucial for comprehensive scene representation, yet real-world degradations compromise its efficacy, necessitating degradation-robust fusion paradigms. Existing degradation-robust multi-modal image fusion methods are often hindered by cascaded sub-optimal solution or black-box opacity. To address these challenges, we propose a theory-inspired mutual-promoting deep unfolding framework. It reformulates degradation-robust image fusion as a joint optimization problem, utilizing the degradation model and modality generation mechanism to explicitly model both single-task priors and cross-task dependencies. By decomposing the complex multi-task optimization problem into task-related iterative subproblems, the framework establishes a bidirectional reciprocal information flow between restoration and fusion. This process is further unfolded into a multi-stage deep neural network, where each component explicitly corresponds to a specific mathematical operation. In our framework, the fused cross-modal prior actively regularizes the ill-posed restoration, while the purified modality features continuously refine the fusion output. It ensures a transparent architecture that combines the merits of both model-based and data-driven methodologies. Extensive experiments demonstrate that our paradigm achieves state-of-the-art performance while providing superior interpretability. The code is publicly available at https://github.com/Meskend/MODULE.
Figures & tables
Figure 1: Comparison of existing degradation-robust image fusion paradigms. (a) Cascade paradigms suffer from biased task prior, causing error accumulation. (b) End-to-end paradigms abort the task-specific prior, leading to physically implausible results. (c) Our iterative paradigm is guided by task prior in optimization objectives, resulting in clean and comprehensive results.
Figure 2: Overall network architecture of the proposed MODULE.
Figure 3: Qualitative results when the infrared image suffers from degradations.
Figure 4: Qualitative results when the visible image suffers from degradations.
Datasets
LLVIP Dataset
MSRS Dataset
Degradations
Infrared Degradations
Visible Degradations
Infrared Degradations
Visible Degradations
Methods
SCD ↑
VIF ↑
Qabf↑
SSIM ↑
SCD ↑
VIF ↑
Qabf↑
SSIM ↑
SCD ↑
VIF ↑
Qabf↑
SSIM ↑
SCD ↑
VIF ↑
Qabf↑
SSIM ↑
RM+DDFM
1.293
0.400
0.301
0.650
1.575
0.445
0.338
0.683
1.282
0.480
0.289
0.527
1.354
0.654
0.300
0.667
RM+CrossFuse
0.754
0.355
0.307
0.651
0.831
0.420
0.286
0.530
0.963
0.487
0.353
0.669
0.959
0.518
0.276
0.528
RM+TC-MoA
1.181
0.414
0.374
0.699
1.287
0.478
0.399
0.663
1.293
0.542
0.374
0.683
1.257
0.765
0.392
0.760
RM+EMMA
1.283
0.361
0.333
0.663
1.374
0.447
0.330
0.602
1.353
0.516
0.362
0.662
1.315
0.613
0.337
0.628
Table 1: Quantitative results on degraded infrared and visible image fusion ( best , second-best ).
Figure 5: Qualitative results of ablation study.
Figure 7
Table 3: Evaluation on unseen and compound degradations ( best , second-best ).
Figure 7: Qualitative results of real-world validation and intermediate variable visualization.
Methods
DDFM
CrossFuse
TC-MoA
EMMA
DDBFusion
Text-IF
DRMF
OmniFuse
TG-ECNet
Ours
NIQE ↓
4.360
4.253
4.200
4.668
4.040
4.198
5.115
6.057
5.069
3.667
BRISQUE ↓
31.590
27.927
26.616
25.148
23.288
28.663
41.255
47.784
24.457
22.356
MUSIQ ↑
43.046
44.482
45.368
44.385
43.332
46.212
49.835
42.269
47.670
50.122
Table 4: Experiment on real-world images and convergence analysis of intermediate variables.
Table 6: Quantitative comparison of object detection performance and computational complexity.
Appendix figures & tables10 assets
Supplementary material from the paper’s appendix.
Appendix
Method
Gaussian Noise
Stripe Noise
LLVIP
MSRS
LLVIP
MSRS
SCD
VIF
Qabf
SSIM
SCD
VIF
Qabf
SSIM
SCD
VIF
Qabf
SSIM
SCD
VIF
Qabf
SSIM
DDFM
1.246
0.408
0.302
0.663
1.293
0.493
0.301
0.671
1.341
0.392
0.300
0.638
1.272
0.466
0.278
0.383
CrossFuse
0.657
0.355
0.303
0.648
0.937
0.505
0.377
0.897
0.851
0.355
0.310
0.654
0.988
0.470
0.329
0.440
TC-MoA
1.110
0.417
0.372
0.707
1.322
0.560
0.394
0.899
1.252
0.410
0.375
0.691
1.263
0.523
0.354
0.466
EMMA
1.244
0.364
0.332
0.668
1.334
0.532
0.383
0.885
1.321
0.359
0.334
0.658
1.372
0.500
0.342
0.440
Appendix
Table 7: Quantitative results of infrared image restoration and fusion under Gaussian and Stripe noise ( best , second-best ).
Method
Low Light
Defocus Blur
LLVIP
MSRS
LLVIP
MSRS
SCD
VIF
Qabf
SSIM
SCD
VIF
Qabf
SSIM
SCD
VIF
Qabf
SSIM
SCD
VIF
Qabf
SSIM
DDFM
1.620
0.365
0.343
0.515
1.158
0.617
0.285
0.539
1.530
0.447
0.272
0.707
1.413
0.685
0.243
0.691
CrossFuse
0.825
0.323
0.305
0.414
0.837
0.469
0.241
0.367
0.856
0.474
0.169
0.523
1.068
0.590
0.241
0.557
TC-MoA
1.241
0.369
0.335
0.436
1.070
0.812
0.384
0.728
1.224
0.500
0.342
0.734
1.306
0.783
0.333
0.755
EMMA
1.302
0.364
0.301
0.443
1.039
0.612
0.317
0.515
1.339
0.494
0.250
0.627
1.414
0.660
0.296
0.636
Appendix
Table 8: Results of visible image restoration and fusion under Low Light and Defocus Blur.
Gaussian Noise
LLVIP
MSRS
SCD
VIF
Qabf
SSIM
SCD
VIF
Qabf
SSIM
VLU+DDFM
1.574
0.522
0.398
0.826
1.490
0.660
0.371
0.770
VLU+CrossFuse
0.812
0.462
0.383
0.654
0.972
0.494
0.345
0.661
VLU+TC-MoA
1.395
0.567
0.522
0.820
1.395
0.699
0.460
0.798
VLU+EMMA
1.480
0.484
0.439
0.736
1.491
0.568
0.399
0.732
VLU+DDBFusion
1.523
0.470
0.324
0.806
1.451
0.604
0.326
0.743
Appendix
Table 9: Quantitative results on Visible Gaussian Noise degradation ( best , second-best ).
Figure 8: Results under compound degradation on LLVIP, where low light and defocus blur are applied to the visible image simultaneously. The insets enlarge the red-boxed regions.
Table 17Table 18
Figure 9: Qualitative results in MRI-PET image fusion.
Metrics
CDDFuse [ 38 ]
EMMA [ 40 ]
GIFNet [ 3 ]
DCEvo [ 11 ]
DDBFusion [ 37 ]
Mask-Difuser [ 21 ]
Ours
SCD ↑
1.529
1.471
1.296
1.478
1.271
1.619
1.616
VIF ↑
0.776
0.565
0.416
0.787
0.561
0.759
0.793
Qabf↑
0.751
0.610
0.339
0.742
0.508
0.694
0.753
SSIM ↑
0.632
0.370
0.225
0.373
0.503
0.373
0.726
Appendix
Table 14: Quantitative comparison on medical image fusion ( best , second-best ).
Figure 10: Qualitative results of coefficient analysis.
Coefficients
SCD ↑
VIF ↑
Qabf ↑
SSIM ↑
α2=0,λp=2+0.1k
1.350
0.572
0.404
0.836
α2=50,λp=2+0.1k
1.699
0.584
0.512
0.847
α2=8,λp=10
1.349
0.583
0.462
0.811
α2=8,λp=0
1.284
0.384
0.368
0.631
α2=8,λp=2+0.1k
1.516
0.591
0.498
0.873
Appendix
Table 15: Ablation study on hyper-parameters α2 and λp ( k : k -th iteration) ( best , second-best ).
Department of Biomedical Engineering, Hefei University of Technology · Faculty of Information Engineering and Automation, Kunming University of Science and Technology · School of Information Science and Technology, University of Science and Technology of China
Foshan University, Foshan, China · China University of Mining and Technology, Beijing, China · Kunming University of Science and Technology, Kunming, China