cs.CVNov 19, 2026

Dynamics-Guided Conditional MeanFlow from Regional Interaction to Internal Revision and Its Application to CT Imaging

Authors: Md Shifatul Ahsan Apurba, Md Selim, Jin Chen

Organizations: Department of Biomedical Informatics and Data Science, University of Alabama at Birmingham, Birmingham, AL, USA · Department of Computer Science, Florida Polytechnic University, Lakeland, FL, USA · Division of Nephrology, Department of Medicine, University of Alabama at Birmingham, Birmingham, AL, USA

Abstract

Conditional image enhancement requires spatially varying corrections, yet fixed-depth models allocate similar computational budgets regardless of where additional refinement is needed. Although one-step flow models reduce inference costs and iterative restoration methods introduce subsequent corrections, how predicted transformation dynamics can guide internal feature refinement remains underexplored. We introduce IRCMF, a dynamics-guided Conditional MeanFlow framework that combines regional interaction with recurrent internal revision. The decoder predicts signed interval velocity and a learned velocity-change cue. A soft-region graph aggregates contextual information for velocity estimation, while a dynamics-conditioned graph establishes regional relationships to guide recurrent bottleneck updates. The revised features are processed by the shared decoder to recompute velocity, establishing feedback between transformation dynamics and internal representations. An actor-critic policy controls regional updates and further revisions to balance enhancement quality and computational cost. We evaluate IRCMF on two computed tomography (CT) datasets, NLST for STANDARD-to-LUNG kernel enhancement and LDCT-and-Projection-data for simulated low-to-routine-dose enhancement. With nine decoder evaluations, IRCMF achieves slice-level PSNR of 36.24±3.4936.24 \pm 3.49 dB and SSIM of 0.97±0.010.97 \pm 0.01 on NLST, and PSNR of 32.45±1.9732.45 \pm 1.97 dB and SSIM of 0.84±0.050.84 \pm 0.05 on LDCT-and-Projection-data. The learned policy reduces average decoder evaluations to 4.42 and 3.45, respectively, lowering per-slice latency from 97.00 to 51.82 ms and from 97.12 to 41.95 ms, with PSNR reductions of only 0.20 and 0.06 dB.

Figures & tables

Explore similar work

Apr 28, 2026

RA-CMF: Region-Adaptive Conditional MeanFlow for CT Image Reconstruction

The use of CT imaging is important for screening, diagnosis, therapy planning, and prognosis of lung cancers. Unfortunately, due to differences in imaging protocols and scanner models, CT images acquired by different means may show large differences in noise statistics, contrast, and texture. In this study, we develop a novel conditional MeanFlow pipeline for CT image reconstruction. We introduce a conditional MeanFlow network that models the enhancement trajectory by predicting image-conditioned flow fields given intermediate image states. The image enhancement network is trained with a MeanFlow consistency loss along with the image reconstruction loss. In order to provide an adaptive refinement process in terms of spatial location of enhancements, we integrate a regional reinforcement learning-driven policy network into our approach. The policy network receives information about the MeanFlow rollouts and provides predictions in terms of tile-wise refinement budgets, stopping criteria, and total budget allocation of enhancement processes. Our policy network is trained through reinforcement learning in a policy gradient framework, where the goal of the training reward is to maximize improvement of enhancements while minimizing unnecessary computations and avoiding instabilities. In this way, our approach combines conditional flow-based enhancement with reinforcement learning-based spatial enhancement control. This allows our approach to focus more attention on enhancing difficult areas while stabilizing areas already showing sufficient quality. Our results show high accuracy in the tumor ROI, with the average radiomic feature CCC being 0.96, an average PSNR of 31.30 ±\pm 4.16, and average SSIM of 0.94 ±\pm 0.07. Moreover, there is an improvement in the overall quality of images, with an average PSNR of 34.23 ±\pm 1.71 and average SSIM of 0.95 ±\pm 0.01.
Feb 27, 2026

Efficient Flow Matching for Sparse-View CT Reconstruction

Generative models, particularly Diffusion Models (DM), have shown strong potential for Computed Tomography (CT) reconstruction serving as expressive priors for solving ill-posed inverse problems. However, diffusion-based reconstruction relies on Stochastic Differential Equations (SDEs) for forward diffusion and reverse denoising, where such stochasticity can interfere with repeated data consistency corrections in CT reconstruction. Since CT reconstruction is often time-critical in clinical and interventional scenarios, improving reconstruction efficiency is essential. In contrast, Flow Matching (FM) models sampling as a deterministic Ordinary Differential Equation (ODE), yielding smooth trajectories without stochastic noise injection. This deterministic formulation is naturally compatible with repeated data consistency operations. Furthermore, we observe that FM-predicted velocity fields exhibit strong correlations across adjacent steps. Motivated by this, we propose an FM-based CT reconstruction framework (FMCT) and an efficient variant (EFMCT) that reuses previously predicted velocity fields over consecutive steps to substantially reduce the number of Neural network Function Evaluations (NFEs), thereby improving inference efficiency. We provide theoretical analysis showing that the error introduced by velocity reuse is bounded when combined with data consistency operations. Extensive experiments demonstrate that FMCT/EFMCT achieve competitive reconstruction quality while significantly improving computational efficiency compared with diffusion-based methods. The codebase is open-sourced at https://github.com/EFMCT/EFMCT.
Oct 29, 2026

FFAI: Flow Matching with Feedback Training and Adaptive Initialization for CT Reconstruction

Although low-dose, sparse-view, and limited-angle CT involve distinct degradation mechanisms, all three pose reconstruction challenges due to limited measurement information and can therefore be addressed within a unified framework. In iterative image restoration with flow matching, prediction errors may cause inference states to deviate from the prescribed training path, while a fixed initialization may be unsuitable for inputs with varying degradation severity. We propose a unified conditional flow matching method that conditions on the initial reconstruction and combines feedback-aware training with degradation-adaptive initialization. During training, a teacher network simulates inference updates to generate shifted states, from which a student network learns to recover high-quality reference images, improving its ability to handle prediction errors. During inference, the starting time is selected based on the noise level or extent of missing projection data, and the noise added to the initial state is adjusted accordingly to adapt the starting point to the input. Experiments on public benchmark datasets show that the proposed method achieves better quantitative results than the compared methods across all three reconstruction tasks, effectively suppressing noise and artifacts while preserving anatomical structures and details.