Environment-Aware Probabilistic State Estimation of Continuum Robots from Planar Imaging
Authors: Aedan Mangan, Spencer Teetaert, Chengnan Shentu, Michael G. Brandel, Jeremy J. Heit, Alexander Norbash, Timothy D. Barfoot, Nikolay Atanasov, Tania K. Morimoto, Jessica Burgner-Kahrs
Organizations: Contextual Robotics Institute, University of California San Diego, USA. · University of Toronto Robotics Institute, Canada. · Departments of Radiology and Neurosurgery, Stanford University, USA. · School of Medicine, University of Missouri-Kansas City, USA.
Continuum robots are compliant along their entire length, making them well suited to navigating confined environments where contact with surrounding structures is often unavoidable. However, this compliance makes their modeling more complex compared to rigid robots, especially under contact, so their state must often be estimated from information available during operation. In many applications, the environment is known in advance, for example from preoperative imaging in medicine or from design models in industrial inspection. We present a probabilistic state estimator that represents the known environment as a signed distance field, informing the estimated shape. Continuous in arclength and time, it estimates the full state from asynchronous measurements anywhere along the robot. It also fuses planar images of body-fixed markers from a moving camera with commanded actuation, so the robot needs no embedded sensors. In a simulated aortic arch and a hardware phantom, the estimator tracked the robot into the target branch, and with a single view, using the known environment lowered the tip error from 2.5% to 1.6% and from 20.0% to 11.3% of the robot length, respectively. The continuous estimate of the full state and its uncertainty can support navigation and control of sensorless continuum robots.
Figures & tables
Fig. 1: Environment-aware probabilistic state estimation. (a) A known environment from a preoperative scan (e.g., the aortic arch) is fused with (b) intraoperative planar imaging and robot actuation to estimate (c) the continuum robot’s pose, strain, and velocity x(s,t)={Twb,ε,ϖ} , continuous in arclength s and time t . Ellipses show covariance with (green) and without (dashed gray) environment factors. Accounting for the known environment shrinks the depth uncertainty that planar imaging alone cannot resolve.
Fig. 2: The robot state is the pose Twb(s,t) of the backbone frame {b} at arclength s and time t relative to the world frame {w} . A marker at a known body-frame offset rb is viewed by a camera with known, time-varying pose Tcw(t) and appears at pixel (u,v) in the image. Observing body-fixed markers with an external camera allows the robot itself to remain sensorless.
Fig. 3: Environment factor based on the signed distance d(pwb(s,t)) from a backbone point (orange) to the known environment O , for a robot of radius r . (a) Without contact ( d>r ), the factor adds no cost. (b) In contact, d=r , and penetration ( d<r ) adds the residual r−d , pushing the backbone away from O . (c) Penalty on one slice of the aortic arch scan, zero inside the dashed line offset by r from the vessel wall (solid). The factor keeps the body out of O but leaves it free elsewhere.
Fig. 4: Factor graph of a two-segment tendon-driven continuum robot, with camera and environment factors omitted. (Left) Each tendon length is a polyline through routing points qj,n offset from the backbone pn , for proximal (purple) and distal (blue) tendons. (Right) State nodes (triangles) at two time steps, linked by space-time prior, insertion, and tendon factors. Each tendon length informs every node the tendon spans.
Fig. 5: Illustration of the estimated covariance (blue) for three camera poses (see Supplementary Video S1). A single view cannot resolve depth, so the covariance stretches along the optical axis and follows the camera pose.
Fig. 6: Continuum robot commanded into a known cylinder, imaged from the frontal view only. (a) Before contact ( t=4 s) and (b) in contact ( t=14 s), with the estimated backbone (black), ground truth frames, and covariance ellipsoids (blue). (c) Estimated tip position (dashed) in x , y , and z of {w} with ±3σ bounds with (colored) and without (gray) the environment factor, and ground truth (black). Contact with the known environment tightened the estimate.
Fig. 7: Simulated navigation from the descending aorta into a supra-aortic branch, estimated from the frontal view with the environment factor (case C of Table I ). (a)–(c) Estimate at t=7 , 14 , and 32 s, with backbone frames and position covariance ellipsoids (purple). (d) Oblique view of the estimate at t=32 s and (e) ground truth. (f) Estimated tip position in {w} (dashed) with ±3σ bounds (shaded) and ground truth (black). The known vessel geometry let the estimator track the tip through the arch from one view.
Simulation
Hardware
Case
Views
Env.
Images
RMSE
NEES
Images
RMSE
NEES
A
1
42
2.5
2.8
42
20.0
6.9
B
3
126
0.9
1.5
85
10.5
5.0
C
1
✓
42
1.6
2.6
42
11.3
5.8
D
3
✓
126
0.9
1.6
85
8.9
5.0
TABLE I: Mean Tip RMSE (% of L ) and NEES in the Aortic Arch
Fig. 8: Estimation on hardware in an aortic arch phantom. (a) Robot teleoperated into the target branch of the transparent phantom, imaged by a camera on a serial robot arm from three views. (b) Estimated tip position (dashed) with ±3σ bounds (shaded) and ground truth (black) over one trial, from all three views with the environment factor (case D of Table I ). The estimate tracked the tip within its bounds for most of the trial.
Technical University of Munich, TUM School of Engineering and Design, Munich Institute of Robotics and Machine Intelligence (MIRMI), Chair of Automatic Control.