Generative priors are state-of-the-art for modeling medical images in image reconstruction tasks, but reconstruction with video priors takes tens of seconds to minutes per frame. Latent priors inherit the errors of their autoencoder, the memory of pixel-space whole-frame priors grows with the frame size, and pixel-space patch priors are slow for two reasons. First, their deep networks process every frame at full resolution at every sampling step, even though early steps resolve only low frequencies. Second, their samplers spend many network evaluations per sampling step on overlapping windows, multiple re-noising rounds, or backpropagation through the prior. We introduce TesseraFlow, a complex-valued pixel-space flow prior that reduces the first cost. A global encoder reads a low-resolution view of every frame once per sampling step. A single shallow decoder operates on this view during early steps and on full-resolution space-time tiles during later steps, so no network processes a whole frame at full resolution. Our sampler, ReTile, addresses the second reason. We use randomized grid shifting at every sampling step along with re-noising, which acts as a stochastic gradient instead of computing overlapping tiles, so a single network pass per sampling step suffices. On its own, ReTile speeds up an existing global-context patch prior by 6-9x, and our prior adds a further 3-5x speedup. TesseraFlow reconstructs about one 256x256 frame per second, 20-367x faster than patch and latent video priors, and can match or exceed the best generative baseline on cardiac, brain, and abdominal MRI and lung CT, at a fraction of its GPU time.
Figures & tables
Figure 2: TesseraFlow and ReTile. One sampling step: a coarse step ( t<ts , top, purple) or a fine step ( t≥ts , middle, teal), and the schedule of steps (bottom). At every step, the encoder Eθ reads a low-resolution version of every frame, the size of a tile. In a coarse step, the shallow decoder Lθ predicts the velocity of this low-resolution video from all encoder features Gt . In a fine step, it predicts the velocity of each space-time tile from the tile and the features at its location, and the tile predictions are placed side by side. ReTile refines the predicted clean video against the measurements, re-noises it, and moves the tiles to a new random offset for the next step.
OCMR radial R=16
Brain 1D VD R=8
Abdominal PROPELLER R=8
Lung CT R=12
Time ↓
Method
PSNR ↑
SSIM ↑
PSNR ↑
SSIM ↑
PSNR ↑
SSIM ↑
PSNR ↑
SSIM ↑
(s/frame)
L1-wavelet SENSE [ 32 ] / FBP
35.28 ± 3.03
.909 ± .030
29.09 ± 2.44
.837 ± .068
28.43 ± 0.99
.852 ± .027
25.26 ± 0.84
.314 ± .027
0.48 ± 0.44
Spatio-temporal ADMM-TV [ 3 ]
39.28 ± 3.19
.957 ± .014
30.35 ± 2.04
.893 ± .038
32.31 ± 1.31
.899 ± .020
36.84 ± 1.06
.961 ± .008
2.79 ± 1.72
PaDIS [ 18 , 44 ]
40.05 ± 2.75
.954 ± .015
33.56 ± 2.22
.896 ± .043
32.62 ± 1.39
.916 ± .019
37.35 ± 0.85
.919 ± .009
219 ± 150
LPGC [ 56 ]
41.09 ± 3.16
.967 ± .012
35.12 ± 1.53
.941 ± .024
33.71 ± 1.76
.927 ± .018
38.47 ± 0.98
.959 ± .008
20.1 ± 3.10
Latent [ 51 ] + DPS [ 6 ]
31.42 ± 1.85
.835 ± .023
31.98 ± 1.27
.921 ± .023
29.88 ± 1.19
.861 ± .022
31.86 ± 1.11
.621 ± .044
145 ± 114
Table 1: Reconstruction quality on the evaluation subsets ( Sec. 4.2 ): PSNR (dB) and SSIM, mean ± standard deviation over the videos. Time: seconds per frame of the reconstruction algorithm, mean ± standard deviation over the four settings; with M samples, one per GPU, the latency ( M times this in GPU time). Best in bold , second underlined .
Require: measurements y , operator A , noise level σ , prior Eθ,Lθ ,
Require: times 0=t0<⋯<tN=1 , switch time ts
1:
x∼N(0,I)
2:
for n=0 to N−1 do
3:
t←tn , t′←tn+1
4:
o∼U{0,…,W−1} , (a,b)j∼U{0,…,p−1}2▹ New tiling ( Sec. 3.3 )
5:
G←Eθ(Dgx,t) on each block (offset o ) ▹ Eq. 3
Table 3
Figure 3: Qualitative comparison , one frame per dataset, zoomed in on the moving anatomy (TesseraFlow: 120 steps, one sample). Last column: the reference with the zoomed region (orange) and the line (dashed) of the space–time strip. Numbers: frame PSNR (dB) / SSIM.
Figure 4: Where the time goes, and temporal consistency (abdominal MRI). (a) Seconds per frame and component on one 20-frame video (log scale), with the total. (b) Error of the frame-to-frame change in one video, averaged over time, in % of the image’s RMS; numbers: temporal NRMSE over the 7 videos.
Method
NFE ↓
FPS ↑
Mem. (GB) ↓
PSNR ↑
tNRMSE (%) ↓
Spatio-temporal ADMM-TV
–
0.48
0.3
30.35
21.9
PaDIS
1040
< 0.02
33.0
33.56
16.7
LPGC
400
< 0.05
2.1
35.12
13.9
Latent + DPS
750
< 0.02
23.0
31.98
18.4
BC-DDS
100
0.41
3.4
32.99
15.5
TesseraFlow (60 steps, M=1 )
60
1.52
1.6
34.88
14.0
Table 2: Cost and temporal consistency on the brain MRI subset. NFE: sequential network evaluations. FPS: frames per second (with M samples on M GPUs, the latency). Mem.: peak memory per GPU. tNRMSE: temporal NRMSE ( Sec. 4.2 ).
Figure 5: In vivo abdominal PROPELLER scan at 512×512 : frames across one 92-frame video, each from its own blade (inset). Top: each blade alone with parallel imaging (GRAPPA), with streaks and noise. Bottom: TesseraFlow, without them.
OCMR
Brain
Abd.
Lung
Prior, sampler
FPS
PSNR
FPS
PSNR
FPS
PSNR
FPS
PSNR
LPGC, original
< 0.06
41.09
< 0.05
35.12
< 0.05
33.71
< 0.06
38.47
LPGC, ReTile
0.31
40.11
0.36
34.89
0.31
34.33
0.36
39.22
TesseraFlow, ts=0
0.58
40.09
0.57
34.95
0.49
33.83
0.76
39.37
TesseraFlow
1.15
40.47
1.52
34.88
0.96
34.12
1.65
39.40
Table 3: Prior and sampler : frames per second (FPS, ↑ ) and PSNR (dB, ↑ ) on each evaluation subset, from the LPGC prior [ 56 ] with its own sampler (400 evaluations), changing one design choice at a time to ours. ts=0 : no coarse steps. Highest FPS in bold .
Figure 6: Tiling. Left: error across the frame, averaged over the 10 OCMR evaluation videos and along rows and columns. Fixed tiles err more, exactly at their edges (dashed). Right: PSNR on the OCMR evaluation subset against time per frame.
Figure 7: Native resolution. (a) A lung CT test frame on the scanner’s 512×512 grid; LPGC and TesseraFlow are trained at 512×512 with their 256×256 recipes. (b) Reconstruction time and peak memory, and memory of one training step.
Prior
Params (M)
GFLOPs / eval.
NFE
TFLOPs / frame
Train (GPU-h)
PaDIS
17.39
2,646 ∗
1,040
2,751
7.9
LPGC
17.39
1,719
400
688
13.6
Latent + DPS
31.71
3,259 ∗
750
2,444
29.0
BC-DDS
17.4
854
100
85
–
TesseraFlow (60 steps)
17.20
190
60
11
11.8
Table S1 : Model size and compute on brain MRI ( 256×256 ): parameters, network GFLOPs per evaluation and frame (matrix products, convolutions, and attention, without data consistency; for TesseraFlow the mean over its coarse and fine steps), sequential evaluations of the published sampler (NFE, Tab. 2 ), network TFLOPs per frame, and GPU-hours to train the OCMR prior (the latent prior to 750 kimg). ∗ Including backpropagation through the prior (and the decoder).
Dataset
Trained on
T
Train frames
Test videos
Test frames
OCMR cine MRI
OCMR
10–28
2665
39 (10)
866 (229)
Brain, head motion
fastMRI brain T2
10
7680
96 (32)
960 (320)
Abdominal MRI
Abdominal
20
2465
20 (7)
400 (140)
Lung CT
4D-Lung
10
13250
40 (5)
400 (50)
Table S2 : Evaluation settings. Each video is one slice followed over time, and training and test data come from disjoint scans, exams, and patients. T is the number of frames per video; parentheses give the evaluation subset of Table 1 . Sampling: golden-angle radial at R=16 (OCMR), 1D VD masks at R=8 (brain), one 32-line PROPELLER blade per frame ( R=8 , abdominal), and 30 views per phase ( R=12 , lung CT).
Figure S1 : Unconditional samples of TesseraFlow (coarse phase, ts=0.5 , 100 Heun steps, one seed, no selection): the first two 5-frame clips drawn on each dataset, all frames. Magnitude (MRI) or attenuation (CT), each clip scaled to its own range.
Figure S2 : Unconditional brain samples with and without the global encoder (both at 1,500 kimg; 100 Heun steps, same noise), from the tiles alone ( ts=0 ) and with the coarse phase ( ts=0.5 ): the first two 5-frame clips of each run, all frames. Magnitude, each clip scaled to its own range.
Figure S3 : PSNR of the final TesseraFlow ( ts=0.8 , 60 steps) on the selection data (training or validation scans, never test data) against the data-consistency σ , relative to the selected value. The selected σ is the best on every dataset, and halving or doubling it costs at most 0.49 dB.
Method
OCMR
Brain
Abd.
Lung
Mean
L1-wavelet SENSE / FBP
0.71
0.22
0.97
0.01
0.48
Spatio-temporal ADMM-TV
3.86
2.08
4.49
0.71
2.79
PaDIS
320
93.1
376
88.0
219
LPGC
18.1
24.1
21.0
17.3
20.1
Latent + DPS
240
61.4
246
33.3
145
BC-DDS
2.80
2.44
3.02
2.54
2.70
Table S3 : Reconstruction time per frame (s, ↓ ) on the evaluation subsets: sampler or solver time per video divided by its number of frames, on one NVIDIA RTX PRO 6000 Blackwell Max-Q. Table 1 reports the mean. Best in bold .
Figure S4 : Quality against reconstruction time per frame on the four evaluation subsets (data of Tab. 1 and Tab. S3 ). Stars: TesseraFlow; triangles: the LPGC prior under ReTile. Filled: 60 steps; dot: 120 steps; open: 120 steps and four samples on four GPUs, at the latency of one. The 120-step LPGC runs shared their GPUs, so their time is twice that of its timed 60-step run, since all of its steps run on patches.
Figure S5 : Qualitative comparison on other test videos (layout of Fig. 3 ; TesseraFlow with 120 steps and one sample). PSNR (dB) / SSIM of the frame, best in bold; badges: reconstruction time per frame.
Figure S6 : Qualitative comparison on further test videos (layout of Fig. 3 ; TesseraFlow with 120 steps and one sample). PSNR (dB) / SSIM of the frame, best in bold; badges: reconstruction time per frame.
OCMR
Brain
Abdominal
Lung CT
Method
PSNR ↑
SSIM ↑
PSNR ↑
SSIM ↑
PSNR ↑
SSIM ↑
PSNR ↑
SSIM ↑
L1-wavelet SENSE / FBP
35.42
.915
28.83
.837
28.33
.846
25.73
.317
Spatio-temporal ADMM-TV
39.46
.960
30.38
.897
32.07
.893
36.48
.947
LPGC [ 56 ]
41.31
.970
34.98
.940
33.66
.925
37.59
.940
BC-DDS [ 27 ] (2D prior)
35.46
.914
32.93
.901
28.70
.828
36.73
.931
TesseraFlow (60 steps, M=1 )
40.73
.966
34.68
.936
33.84
.923
39.33
.962
Table S4 : TesseraFlow, LPGC, BC-DDS, and the classical baselines on the full test sets (OCMR 39, brain 96, abdominal 20, and lung CT 40 videos); PaDIS and Latent + DPS only on the evaluation subsets of Tab. 1 . PSNR in dB / SSIM. Best in bold .
Baseline
OCMR
Brain
Abd.
Lung
TesseraFlow (60 steps, M=1 ) −
L1-wavelet / FBP
+5.45 (.002)
+5.79 ( < .001)
+5.69 ( < .001)
+14.14 ( < .001)
ADMM-TV
+1.25 (.018)
+4.53 ( < .001)
+1.81 ( < .001)
+2.56 ( < .001)
PaDIS
+0.45 (.27)
+1.32 ( < .001)
+1.51 ( < .001)
+2.05 ( < .001)
LPGC
-0.61 (.038)
-0.24 (.016)
+0.42 (.021)
+0.93 (.063)
Latent + DPS
+9.09 ( < .001)
+2.91 ( < .001)
+4.24 ( < .001)
+7.54 ( < .001)
Table S5 : Paired t -tests of PSNR on the evaluation subsets of Tab. 1 : mean difference TesseraFlow − baseline (dB) and two-sided p -value, with the videos of each subject averaged first (4 OCMR scans, 32 brain subjects, 7 abdominal exams, 5 lung CT patients). Bold: p<0.05 ; no correction for multiple comparisons.
Variant
PSNR ↑
SSIM ↑
TesseraFlow (full) : σ=0.005 , K=10 , weight νt2
41.23
.957
Mixed tile sizes in training
40.90
.956
Linear data weight 1−t , best σ=0.02
41.01
.951
σ×0.5
40.93
.949
σ×2
40.74
.955
K=5 CG iterations
40.96
.957
Table S6 : Component ablations on the three OCMR training slices used for tuning (radial, R=16 ; first five frames; 60 steps, ts=0.8 ). Each row changes one component of the full model, shown in the first row. σ is the data-consistency noise level and K the number of conjugate-gradient iterations.
Figure S7 : Seconds per frame against the number of frames T on the abdominal scaling series (baselines at T=20 and 50). Every method works on 5-frame windows, so its cost per frame is constant in T .
Global
Tiling
Re-noise
PSNR ↑
SSIM ↑
Time (s) ↓
OCMR
✓
random (ReTile)
fresh
40.16
0.958
40
✓
fixed tiles and blocks
fresh
39.81
0.956
39
✓
overlapping consensus
fresh
40.19
0.959
431
✓
random
predicted
35.24
0.867
40
✓
overlapping consensus
predicted
34.07
0.840
–
Table S7 : Tiling, global encoder, and re-noising on the OCMR and brain MRI evaluation subsets (10 and 32 videos, 60 steps, without the coarse phase). Re-noising draws fresh noise or reuses the noise predicted by the network. The model without the global encoder is trained identically, with the same data and kimg. PSNR and SSIM inside the exact coil support: the squared error and the SSIM map are averaged over the pixels where the root-sum-of-squares of the coil maps exceeds 5% of its maximum, without the 2-pixel dilation of the scoring mask of Tab. 1 and Fig. 6 . Time: sampler seconds per video (OCMR).
Figure S8 : Unconditional samples of each prior on the four datasets , two each, no selection (middle frame of a 5-frame clip). PaDIS and LPGC use their own samplers, the latent prior 100 Heun steps (TesseraFlow: coarse-to-fine with ts=0.5 ). Magnitude (MRI) or attenuation (CT), each panel scaled to its own range.
Figure S9 : x-t view of the in vivo scan of Fig. 5 : a line through bowel loops on the other side of the abdomen from the line of Fig. 1 c, chosen by the same rule on the zero-filled data and marked on the conventional reconstruction, one image from all 92 blades (left), over all 92 frames, from each frame’s own blade with GRAPPA (one display gain for all frames) and from TesseraFlow.
Figure S10 : Where the global encoder helps on the 32 brain MRI evaluation videos (arrows: gain over the encoder-free model, inside the exact coil support). (a) Reconstruction with the default sampler against the acceleration. (b) One step of the tiles alone, without measurements: the reference is noised to xt , and the plot shows the PSNR gain of the clean estimate xt+(1−t)v against the reference, as a function of the flow time; both models on identical noise and tilings; band: range over the videos.
Evaluations
N
K
PSNR ↑
SSIM ↑
K=1 better
60
60
1
40.09
0.960
–
60
30
2
39.83
0.957
10/10
60
15
4
39.17
0.947
10/10
120
120
1
40.48
0.964
–
120
60
2
40.40
0.964
10/10
Table S8 : Sampling steps versus updates per sampling step on the OCMR evaluation subset (10 videos, without the coarse phase). N sampling steps with K updates each, every update with a new random tiling, conjugate gradients, and fresh re-noising, cost NK network evaluations. PSNR and SSIM with the scoring mask of Tab. 1 . Last column: videos on which K=1 at the same evaluations is more accurate. The 60×1 row is ReTile as in Fig. 6 .
Prior
Steps × rounds, setting
PSNR ↑
SSIM ↑
Time (s) ↓
PaDIS
60×1 , ζ×16
20.62
.142
5.28
LPGC
30×2 , K=10 , η=0
38.11
.948
2.62
Latent + DPS
60, guidance ×2
22.52
.667
2.66
TesseraFlow
60, ts=0.8
39.40
.972
0.61
Table S9 : Equal budget on lung CT: every generative prior at 60 sequential network evaluations, the default of TesseraFlow, on the evaluation subset (5 videos), each baseline with its data-consistency strength retuned for this budget on validation data ( Sec. I ). Steps × rounds: noise levels × Langevin steps (PaDIS), DDIM steps × recurrent rounds (LPGC). Time per frame as in Tab. S3 . Best in bold .
Method
OCMR
Brain
Abdominal
L1-wavelet SENSE [ 32 ]
15.14 ± 4.12
20.65 ± 3.95
29.43 ± 2.77
ADMM-TV [ 3 ]
9.81 ± 3.45
17.06 ± 2.63
19.48 ± 2.75
PaDIS [ 18 , 44 ]
9.31 ± 2.80
12.28 ± 2.45
19.50 ± 3.20
LPGC [ 56 ]
8.20 ± 3.28
10.16 ± 1.52
18.31 ± 3.19
Latent [ 51 ] + DPS [ 6 ]
23.06 ± 2.38
14.50 ± 2.13
27.12 ± 4.14
BC-DDS [ 27 ]
14.19 ± 2.96
12.86 ± 2.20
29.49 ± 3.99
Table S10 : Complex NRMSE (%, ↓ ) on the MRI evaluation subsets: ∥x−xref∥2/∥xref∥2 over the complex frames of a video (zero outside the coil support, as for PSNR), mean ± standard deviation over the videos. Best in bold , second underlined .
L1 / FBP
ADMM- TV
PaDIS
LPGC
Latent + DPS
BC- DDS
TF- 2D
TF 60
TF 120 × 4
OCMR
18.77
10.37
11.28
8.83
14.37
16.93
16.92
10.03
9.14
Brain
26.61
21.94
16.75
13.89
18.37
15.51
15.50
13.98
12.08
Abdominal
33.55
22.05
22.47
23.19
32.31
33.67
31.27
19.72
18.46
Lung CT
20.01
6.45
5.61
6.26
6.09
6.34
6.56
4.27
3.58
Table S11 : Temporal NRMSE (%, ↓ ) of Tab. 2 on every subset, mean over the videos (real images for lung CT). TF: TesseraFlow (steps × samples). Best in bold , second underlined .
MedVAE [ 51 ]
Complex-valued [ 34 ]
Dataset
PSNR ↑
SSIM ↑
PSNR ↑
SSIM ↑
OCMR (10)
38.67 ± 1.50
.976 ± .006
37.52 ± 2.24
.958 ± .010
Brain (32)
33.14 ± 1.38
.950 ± .016
34.52 ± 1.08
.949 ± .019
Abdominal (7)
34.37 ± 1.33
.945 ± .013
32.90 ± 1.55
.917 ± .016
Table S12 : Autoencoder round trip on the MRI evaluation subsets (number of videos in parentheses): the fully sampled reference of each video is encoded and decoded, without measurements, and scored as in Tab. 1 (magnitude, zero outside the coil support), mean ± standard deviation over the videos. MedVAE encodes the real and imaginary parts separately, as in the latent baseline; the complex-valued autoencoder takes them as two channels. Better in bold .
Figure S11 : Bowel motion of the in vivo scan across settings. Slow intensity change (9- minus 31-frame moving average) at the first arrow of Fig. 1 c (5.2 s), the strongest change along its line in the zero-filled data, over all 92 frames: (a) data-consistency weights σ , (b) four independent noise draws at σ=0.04 . Gray: the zero-filled blades (data only; smaller, since a single blade blurs the image); dashed: the static posterior body. The traces correlate with the zero-filled one at 0.90–0.92 and with that of the GRAPPA blades (not shown) at 0.98 or more.
Figure S12 : Free-breathing in vivo PROPELLER scan : frames spread over one 56-frame video, each from the single blade acquired at that time (inset). Left: gridding of the blade; right: TesseraFlow (badge: reconstruction speed).
Figure S13 : x-t view of the free-breathing in vivo scan of Fig. S12 : the centre column of the body across the anterior abdominal wall, which moves with breathing, marked on the conventional reconstruction, one image from all 56 blades (left), over all 56 frames, from the gridding of each frame’s own blade (zero-filled, one display gain for all frames) and from TesseraFlow.
Figure S14 : Third in vivo PROPELLER scan (breath hold, native 512×512 ): frames spread over one 78-frame video, each from the single blade acquired at that time (inset: acquired lines white, GRAPPA-filled lines gray). Top: the blade with GRAPPA; bottom: TesseraFlow, with the model and settings of Fig. 5 .
Figure S15 : x-t view of the third in vivo scan of Fig. S14 : a line through bowel loops chosen from the blade data alone, marked on the conventional reconstruction, one image from all 78 blades (left), over all 78 frames, from each frame’s own blade with GRAPPA (one display gain for all frames) and from TesseraFlow.
Image reconstruction recovers images, volumes, or scenes from incomplete, noisy, indirect, or compressed measurements using physical models and learned priors.