Accurate chest X-ray radiology report generation (RRG) requires recognizing clinically relevant abnormalities and accurately describing them. Although Group Relative Policy Optimization (GRPO) improves the clinical accuracy of generated reports, our analyses suggest limited improvements in visual representations for abnormality recognition. To address this limitation, we propose a selective regional visual distillation framework that enhances visual representations of challenging abnormalities while preserving existing visual capabilities. Specifically, we train a region-aware teacher with targeted supervision on challenging anatomical regions to acquire complementary visual knowledge. Rather than transferring all teacher features, we verify their utility through regional feature replacement and select only those that improve the original student's performance. We further introduce a Spatially Gated Residual Adapter (SGRA) to distill these verified features while minimizing interference with the student's existing visual representations. Experiments on MIMIC-CXR and IU-Xray demonstrate improved clinical report accuracy and region-level abnormality recognition across different multimodal large language model backbones, while largely preserving performance on non-target findings.
Figures & tables
Figure 1: Clinical performance and visual attribution before and after GRPO. We focus on Qwen3-VL, as its larger clinical gains from GRPO compared with MedGemma make the effects of GRPO more evident. (a) Representative CXR cases show similar disease-region attribution patterns despite corrected clinical predictions after GRPO. (b) Exchanging visual encoders between SFT and GRPO models has little effect on CheXbert F1 and RadGraph F1. The multimodal projector remains frozen in both stages. Parentheses indicate the source of the substituted visual encoder (VE), while the leading model name indicates the source of the remaining components. GT denotes ground truth.
Figure 2: The region-aware teacher, trained with region-level supervision, provides targeted guidance for enhancing the student’s visual representations in challenging regions. When the student incorrectly predicts a disease while the teacher correctly identifies it in the corresponding image region, that region is selected for distillation after passing regional feature utility verification. The visual tokens corresponding to the selected region are then extracted from both models, and the student’s tokens are aligned with their teacher counterparts to improve the visual representations associated with the student’s prediction errors.
Figure 3: Overview of the proposed selective regional visual distillation framework. Region-Aware Teacher Training: A region-aware teacher is trained with region-specific questions and anatomical annotations to enhance visual representations of disease-associated regions in challenging cases. Regional Feature Utility Verification: Teacher features are substituted into the corresponding student regions, and the resulting changes in the student’s correct-answer scores are used to identify beneficial regional features for distillation. Selective Regional Distillation with SGRA: A Spatially Gated Residual Adapter (SGRA) learns from the selected teacher features through regional feature distillation, while a feature preservation loss constrains changes to non-target regions.
Dataset
Method
Venue
NLG Metrics ↑
Clinical Metrics ↑
B-1
B-2
B-3
B-4
METEOR
ROUGE-L
Micro-F1
Macro-F1
RG-F1
MIMIC-CXR
RGRG [ 39 ]
CVPR’23
34.36
20.83
13.36
8.73
16.26
25.04
54.25
29.77
22.71
CURV [ 44 ]
NeurIPS’25
30.06
15.86
10.68
6.38
12.02
23.16
41.60
18.57
22.86
MambaXray-VL [ 41 ]
CVPR’25
36.36
20.77
12.61
7.96
14.88
24.85
48.97
22.40
19.61
REVA-PO [ 17 ]
ECCV’26
32.74
20.23
12.96
8.42
16.60
26.35
57.39
30.86
21.24
FairLLaVA [ 6 ]
CVPR’26
36.71
21.03
13.15
8.67
13.93
25.93
59.12
34.64
21.10
Table 1: Comparison with state-of-the-art methods on MIMIC-CXR and IU-Xray. All methods are trained on MIMIC-CXR for RRG and directly evaluated on IU-Xray without any further fine-tuning. Our method uses only MIMIC-CXR for task-specific training, while some baselines may include IU-Xray in their pretraining. Micro-F1 and Macro-F1 are computed using CheXbert, while RG-F1 denotes RadGraph Partial F1. BLEU-1/2/3/4 and METEOR are computed at the corpus level, whereas ROUGE-L and RadGraph Partial F1 are averaged over individual reports. Best and second-best results are highlighted in bold and underlined , respectively.
Method
Selection
SGRA
Lkeep
Micro-F1
Macro-F1
RG-F1
SFT + GRPO
–
–
–
60.44
33.27
27.32
+ Vanilla Distillation
–
–
–
56.48
31.96
24.89
+ Utility Verification
✓
–
–
58.47
34.81
27.03
+ SGRA
✓
✓
–
61.14
35.42
27.62
Ours
✓
✓
✓
63.02
36.27
28.50
Table 2: Ablation study on MIMIC-CXR using MedGemma 1 4B. SFT + GRPO denotes the original model without distillation. Vanilla Distillation uses a standard residual adapter to distill regional features from samples where the student is incorrect but the teacher is correct. Utility Verification follows the same setting but further filters samples based on their verified utility.
Backbone
Method
Micro-F1
Macro-F1
RG-F1
MedGemma 1 4B
SFT + GRPO
60.44
33.27
27.32
+ Ours
63.02
36.27
28.50
Qwen3-VL-8B-Instruct
SFT + GRPO
50.90
26.78
19.80
+ Ours
54.68
30.03
21.82
Table 3: Generalization of our method across different MLLM backbones on MIMIC-CXR. Qwen3-VL-8B-Instruct follows the same training and distillation pipeline described in our method.
Figure 4: Qualitative comparison of visual attribution before and after regional distillation. Representative error-correction cases from MedGemma 1 4B (top) and Qwen3-VL-8B-Instruct (bottom), showing changes in generated reports and visual attribution to the corresponding abnormality regions. Attribution maps are computed using gradient × activation. For Qwen3-VL, attributions are aggregated from the final visual embeddings and DeepStack features, whereas for MedGemma, they are computed at an intermediate visual encoder layer. Due to differences in model architecture, feature resolution, and visualization settings, the attribution maps are computed differently and may exhibit distinct appearances. Therefore, we focus on before-and-after comparisons within each model rather than directly comparing attribution intensities across models.
Abnormality
Method
Challenging Samples
Random Samples
P
R
F1
P
R
F1
Atelectasis
SFT + GRPO
30.91
34.00
32.38
64.79
83.64
73.02
Ours
52.78
63.33
57.58
70.07
87.27
77.73
Consolidation
SFT + GRPO
27.85
29.33
28.57
36.67
73.33
48.89
Ours
36.36
50.66
42.34
41.38
80.00
54.55
Cardiomegaly
SFT + GRPO
26.21
25.33
25.76
62.39
73.17
67.35
Table 4: Region-level abnormality recognition on challenging and randomly sampled cases from MIMIC-CXR. Each subset contains 300 samples: the challenging subset consists of 150 positive and 150 negative cases, while the random subset is randomly sampled. P, R, and F1 denote precision, recall, and F1 score, respectively.
Finding
Count
Method
Precision
Recall
F1
Atelectasis
775
SFT + GRPO
45.37
65.16
53.50
Ours
49.64
70.84
58.37
Consolidation
199
SFT + GRPO
0.00
0.00
0.00
Ours
44.14
32.16
37.20
Cardiomegaly
830
SFT + GRPO
52.39
62.17
56.86
Ours
56.40
68.43
61.84
Table 5: Report-level clinical performance on MIMIC-CXR. Disease labels are extracted from generated and reference reports using CheXbert. Count denotes the number of positive reference cases for each finding in the MIMIC-CXR test set. Other 10 Findings denotes the remaining ten categories not targeted by regional distillation, with their results micro-averaged and reported.
Radiology report generation (RRG) has attracted significant attention due to its potential to reduce the workload of radiologists. The performance of current RRG approaches remains unsatisfactory against clinical standards. This paper introduces a novel RRG method, MLLM-RRG, that integrates multimodal large language models (MLLMs) with various types of clinical knowledge to generate accurate and comprehensive chest X-ray reports. Our method first designs a referring anatomical feature extractor that leverages anatomical knowledge to analyze different regions of the chest X-ray image and extract visual features without explicitly detecting regions. Next, based on the MLLM's decoder, we develop a multimodal report generator that leverages multimodal prompts constructed from dedicated visual features and textual instructions to produce the radiology report in an auto-regressive way. Finally, we introduce a disease-oriented clinical classification and alignment scheme in a multi-task learning manner to leverage disease knowledge to better preserve the clinical relevance among the generated reports. Once the model is trained, we also introduce a novel clinical quality reinforcement learning strategy to enhance the MLLM with report knowledge, further refining the tones of the generated reports towards radiologists. Extensive experiments on the MIMIC-CXR and IU X-Ray datasets demonstrate the superiority of our method over the state of the art. Our codes will be available at https://github.com/viscom-tongji/MLLM-RRG.
Miaojing Shi, Tianyu Cen, Zijie Yue +3
College of Electronic and Information Engineering, Tongji University, Shanghai, China
Radiology report generation (RRG) streamlines clinical workflows and alleviates the burden of radiologists' documentation. Standard vision-language models capture global visual cues and lack fine-grained alignment between anatomical regions and diagnostic text. Most retrieval-augmented methods retrieve complete historical reports, introducing redundant noise and severe vision-text mismatches that trigger clinically risky hallucinations and missed lesions. In this paper, we introduce AR-RRG, an anatomy-guided retrieval-driven method for the generation of radiology reports. AR-RRG consists of two core modules: the anatomy-aware self-training lesion detection network (ASLDNet) and the retrieval-driven radiology report generation (RRRG). ASLDNet leverages anatomy-aware spatial verification (ASV) and class-adaptive dynamic thresholding (CDT) via self-training, delivering accurate lesion localization to support subsequent generation. As the generative branch of AR-RRG, RRRG eliminates clinical hallucinations through dual-granularity retrieval (DR) and complements missing lesions with a neighborhood consensus (NC) mechanism. A parallel continuous visual perception (PCVP) stream converts radiographs into visual tokens through fixed medical encoding and resampling. Multi-scale text and visual features are fused, followed by LoRA-efficient large language model tuning to generate clinically consistent, visually grounded radiology reports. Extensive evaluations on MS-CXR, MIMIC-CXR, and IU X-Ray demonstrate that AR-RRG consistently outperforms state-of-the-art methods across mainstream metrics. Our code will be made publicly available.
Xiang Zhang, Shijie Song, Wanqing Zhao +8
the School of Computer Science, Northwest University, Shaanxi, China · the School of Electronic Information, Northwest University, Shaanxi, China · the School of Art, Northwest University, Shaanxi, China
Radiology reports are essential for diagnostic reasoning and patient care, yet their manual preparation is time-consuming and cognitively demanding. Automatic radiology report generation (RRG) offers a scalable alternative, but existing models often produce lengthy, unstructured narratives that overlook diagnostic cues and multi-view information. We present Clinical-Knowledge Guided Disease-aware Visual-Textual Alignment for QA-Style Radiology Report Generation (CliQ-RRG), a unified two-stage framework for interpretable and clinically grounded reporting. In Stage 1, CliQ-RRG employs a Disease-aware Visual-Textual Alignment module that aligns image and text representations using predicted disease embeddings, reinforced by a Prior-Guided Attention Module (PrAM) to capture multi-view dependencies across current and prior scans. In Stage 2, GraphRAG-guided retrieval augments intermediate textual representations with graph-grounded clinical evidence, and a large language model restructures them into concise, interpretable question-answer (QA) pairs with diagnostic summaries. Experiments on two public chest X-ray benchmarks demonstrate that CliQ-RRG consistently outperforms prior methods across both lexical and clinical metrics, generating accurate and clinically coherent QA-style radiology reports. Code is available at: https://github.com/chandravardhan-singh-raghaw/CliQ-RRG.