cs.CVNov 23, 2026

Reconstructing 3D+t Cardiovascular Flow From Sparse Planar Velocity Fields With Neural Fields

Authors: Viraj Patel, Deblina Bhattacharjee, Katharine Fraser

Organizations: Department of Computer Science University of Bath · Department of Mechanical Engineering University of Bath

Abstract

Reconstructing time-resolved three-dimensional (3D+t) cardiovascular flow from sparse planar measurements is challenging because each plane observes only the two in-plane velocity components, on a small part of the volume. We propose a plane-aware neural-field framework that learns a continuous 3D velocity field from space and time coordinates through a per-plane projection, and then investigate the potential benefits of physics constraints. We evaluate the framework on computational aortic and aneurysm datasets, and on planes resampled from a real cardiac 4D Flow MRI scan. A plain multi-layer perceptron (MLP) was more accurate than classical radial basis function (RBF) interpolation on both computational datasets. For the aorta, a physics-constrained SIREN (PC-SIREN) reduced the rRMSE further to 0.37560.3756, compared with 0.42730.4273 for the plain MLP and 0.72560.7256 for RBF, and it was the most accurate model in every anatomical segment of the MRI data. For the aneurysms the plain MLP remained the most accurate model, with an rRMSE of 0.070.07 to 0.160.16 against 0.550.55 to 0.710.71 for PC-SIREN. Further experiments investigated scanning configuration, number of scans, and spatial resolution. These findings show that continuous neural fields can reconstruct volumetric cardiovascular flow from sparse planar measurements, and that physics constraints have to be matched to the flow.

Figures & tables

Explore similar work

Aug 31, 2026

Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation

Quantifying mitral regurgitation severity remains limited by the assumptions of clinical flow convergence methods, while high-fidelity simulation and volumetric velocimetry are too slow for routine use. We investigate whether a learned solution operator can reconstruct transient three-dimensional transvalvular hemodynamics from the sparse observation an in-vitro experiment actually provides: a single planar velocity slice and two boundary pressure traces. A Deep Operator Network is pretrained on an experimentally benchmarked URANS database spanning eleven mitral regurgitation orifice phantoms, learning a mapping from a masked two-component planar velocity snapshot to the surrounding volumetric field, and is subsequently adapted to unseen target cases by fine-tuning on their sparse measurements. Adaptation reliably corrects the flow topology within the supervised plane, reorienting a strongly eccentric jet that the pretrained operator predicts as straight, and yields full-field predictions in minutes rather than the days required by the underlying simulations. Its influence decays sharply with distance from that plane, however: measured against phase-resolved particle image velocimetry, the reconstruction error rises from 24.6% at 2mm to 52.6% at 6mm, and the resulting mismatch between corrected and uncorrected layers degrades physical consistency. Single-plane supervision thus constrains the observed plane far more effectively than the surrounding volume, which we identify as the principal obstacle to coherent 4D reconstruction from sparse planar data.
May 15, 2026

FLUIDSPLAT: Reconstructing Physical Fields from Sparse Sensors via Gaussian Primitives

Reconstructing continuous flow fields from sparse surface-mounted sensors is central to aerodynamic design, flow control, and digital-twin instrumentation. Existing neural methods for this task typically encode sensor readings into implicit latent codes with little spatial interpretability and limited formal guidance on how representational capacity should scale with observation count. Inspired by 3D Gaussian Splatting, we introduce FLUIDSPLAT, a sensor-conditioned model that predicts K anisotropic Gaussian primitives forming a partition-of-unity scaffold, a spatially explicit and interpretable intermediate representation of the flow. For an idealized Gaussian primitive estimator, we prove an O(K−s/d)O(K^{-s/d}) approximation rate for fields with Sobolev smoothness ss; incorporating NN noisy observations yields a squared-risk decomposition with bias O(K−2s/d)O(K^{-2s/d}) and variance O(σ2K/N)O(σ^{2}K/N).Balancing the two yields K∗ ⁣∼ ⁣(N/σ2)d/(2s+d)K^{*}\!\sim\!(N/σ^{2})^{d/(2s+d)}: primitive count cannot grow freely under sparse sensing, revealing a variance bottleneck that motivates complementing the scaffold with a state-conditioned residual decoder. Across four benchmarks spanning 2D and 3D, FLUIDSPLAT achieves 11-28% error reduction over several strong baselines on cylinder flow, AirfRANS, FlowBench LDC-3D, and PhySense-Car 3D benchmarks.
Sep 16, 2026

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.