Boltz-Flow: Generating High-Quality Robot Action from Boltzmann Machine
Authors: Hengzhi Jiang, Haixu Liu, Jindou Jia, Tinglan Wang, Shaobo Chen, Yiren Zhao, Ziyang Rao, Laiyuan Cui, Jiaxin Dong, Yin Ma, Hai Wei, Jiaqi Bai, Tuo An, Xinyu Zhou, Hao Ban, Hongdong Zhu, Yanqi Wang, Jiaqi Dou, Nuo Qian, Qi Liu, Bin Jin, Chang Wu, Qingfeng Li, Hui Yang, Weiyu Guo, Dicong Qiu, Qi Gao, Jianwei Niu, Kai Wen, Jianfei Yang
Organizations: Beihang University · Beijing QBoson Quantum Technology Co., Ltd. · Nanyang Technological University · The Hong Kong University of Science and Technology (Guangzhou) · The Hong Kong University of Science and Technology
Flow-matching policies integrate a velocity field from a fixed, observation-independent Gaussian source. However, since the source is unimodal and identical across all tasks, the limited representational capacity of Gaussian distributions constrains how far a policy can scale with growing task diversity. Moreover, the source factorizes over time steps and control dimensions, discarding the coordination that manipulation requires. We introduce Boltz-Flow, which replaces Gaussian initialization with a more powerful, observation- and instruction-conditioned Boltzmann source while leaving the base VLA unchanged. Boltz-Flow parameterizes this source with a conditional Boltzmann machine that assigns an energy value to each binary source state. A listwise objective, supervised entirely by offline demonstrations, aligns this energy with the quality of actions produced after frozen flow integration. At inference, the energy defines an Ising instance whose solution is decoded into continuous noise before a single standard integration. We use a physical coherent Ising machine during training. Experiments show that Boltz-Flow improves π0.5 across three benchmarks, outperforming the compared strong policy baselines and competing noise optimization methods on LIBERO and RoboTwin 2.0 and ranking second only to LEAP on LIBERO-Plus. Additional experiments show gains under noise-adapted fine-tuning, with action-to-action warm starts, and on the SmolVLA backbone.
Figures & tables
Figure 1: Four choices of source distribution for a flow-matching policy. Noise-to-Action [ 32 ] draws from a fixed isotropic Gaussian . Action-to-Action [ 23 ] re-centers the source on past actions. Condition-to-Action [ 55 ] predicts it from the current observation I≤t . Boltzmann-to-Action (ours) samples from a learned observation-conditioned Boltzmann distribution, whose energy supports dense couplings and multiple low-energy modes, obtained by Ising sampling on a coherent Ising machine.
Figure 2: Overview of Boltz-Flow. Right. A conditioning module replaces the Gaussian source of a frozen flow-matching policy. It maps the robot observation and instruction to a flow source, which the frozen flow heads integrate into an action chunk for the robot. Left. Inside the conditioning module, a Transformer encoder on the GPU turns the observation and instruction tokens into energy tokens, which clamp the visible layer of a conditional BM. The CIM searches the hidden layer for low-energy binary states. A midpoint- Gaussian -quantile mapping then decodes these states (0-1 embedding) into the continuous flow source.
Method
Spa.
Obj.
Goal
Long
Avg.
Diffusion Policy [ 10 ]
78.3
92.5
68.3
50.5
72.4
Octo [ 18 ]
78.9
85.7
84.6
51.1
75.1
OpenVLA [ 27 ]
84.7
88.4
79.2
53.7
76.5
SpatialVLA [ 35 ]
88.2
89.9
78.6
55.5
78.1
WorldVLA [ 7 ]
87.6
96.2
83.4
60.0
81.8
CoT-VLA [ 56 ]
87.5
91.6
87.6
69.0
83.9
Table 1: LIBERO success rates (%). The upper block reports prior results; the lower block reports our OpenPI evaluations. Entries are ordered by the four-suite average, with π0.5 first in the lower block. “(CIM)” denotes CIM training with SA inference. FT denotes noise-adapted full fine-tuning; dashes indicate unreported results. † denotes our reproduced π0.5 baseline.
Method
Camera
Robot
Language
Light
Background
Noise
Layout
Overall
OpenVLA [ 27 ]
0.8
3.5
23.0
8.1
34.8
15.2
28.5
16.3
WorldVLA [ 7 ]
0.1
27.9
41.6
43.7
17.1
10.9
38.0
25.6
NORA [ 20 ]
2.2
37.0
65.1
45.7
58.6
12.8
62.1
40.5
UniVLA [ 50 ]
1.8
46.2
69.6
69.0
81.0
21.2
31.9
45.8
π0 [ 5 ]
13.8
6.0
58.8
85.0
81.4
79.0
68.9
56.1
π0 -FAST [ 34 ]
65.1
21.6
61.0
73.2
73.2
74.4
68.8
62.5
Table 2: LIBERO-Plus success rates (%) under seven perturbations. Overall is the arithmetic mean across categories. The upper block reports prior results; the lower block reports our OpenPI evaluations. Baselines are ordered by Overall, with π0.5 first and Boltz-Flow variants last in the lower block. “(CIM)” denotes CIM training with SA inference. LIBERO-Plus is used only for evaluation. FT denotes noise-adapted full fine-tuning. † denotes our reproduced π0.5 baseline.
Method
Clean
Random
Fast-WAM [ 54 ]
77.76
1.92
Evo-1 [ 31 ]
65.70
12.50
EventVLA [ 53 ]
65.58
15.74
X-VLA [ 57 ]
67.96
20.95
Spatial Forcing [ 28 ]
77.18
26.74
NoTVLA [ 19 ]
63.28
28.40
Table 3: RoboTwin 2.0 success rates (%). The upper block reports prior results from the accepted paper; the lower block reports our OpenPI evaluations. Entries are ordered by Random success, with π0.5 first in the lower block. Clean uses the standard setting; Random includes all randomizations and distractors. FT denotes noise-adapted full fine-tuning. † denotes our π0.5 baseline.
Method
Spa.
Obj.
Goal
Long
Avg.
π0.5 [ 4 ]
96.4
98.8
95.8
87.6
94.65
π0.5 + VAE noise
97.8
98.8
96.8
92.8
96.55
π0.5 + Boltz-Flow
99.4
98.6
98.2
96.2
98.10
Table 4: Ablation of the initial source distribution. All entries are success rates (%); the base policy is frozen in all three settings.
π0.5 variant
Spa.
Obj.
Goal
Long
Avg.
π0.5 [ 4 ]
96.4
98.8
95.8
87.6
94.65
+ full-parameter FT
98.0
99.2
97.8
96.0
97.75
+ Boltz-Flow
99.4
98.6
98.2
96.2
98.10
+ Boltz-Flow + adapted FT
99.2
99.8
98.4
97.4
98.70
Table 5: Ablation of policy adaptation. Full-parameter FT uses standard Gaussian noise, whereas noise-adapted FT adapts the velocity field to the Boltzmann source. All entries are success rates.
Method
Train
Infer
Spa.
Obj.
Goal
Long
Avg.
Boltz-Flow
SA
SA
99.4
98.6
98.2
96.2
98.1
Boltz-Flow
CIM
SA
99.4
99.8
98.6
96.4
98.6
Boltz-Flow
CIM
CIM
100.0
99.6
99.2
97.0
99.0
Boltz-Flow + FT
SA
SA
99.2
99.8
98.4
97.4
98.7
Boltz-Flow + FT
CIM
SA
99.8
99.6
99.2
97.6
99.1
Table 6: Solver ablation on LIBERO. All entries are success rates (%). The upper block uses a frozen policy; FT denotes subsequent noise-adapted full-parameter fine-tuning.
Method
Train
Infer
Camera
Robot
Language
Light
Background
Noise
Layout
Overall
Boltz-Flow
SA
SA
69.5
76.1
85.9
96.8
97.7
85.5
86.5
85.4
Boltz-Flow
CIM
SA
71.4
77.1
85.0
97.4
97.9
85.4
87.0
85.9
Boltz-Flow + FT
SA
SA
71.4
78.0
87.1
96.8
97.9
89.7
87.0
86.8
Boltz-Flow + FT
CIM
SA
72.2
79.5
86.5
97.2
97.1
90.9
87.9
87.3
Table 7: Training-solver ablation on LIBERO-Plus. All entries are success rates (%); Overall is the arithmetic mean across the seven perturbation categories. The upper block uses a frozen policy; FT denotes subsequent noise-adapted full-parameter fine-tuning.
Figure 3: Solver convergence and Gray-code precision on standard LIBERO. Success rates are averaged equally over the Spatial, Object, Goal, and Long-Horizon suites. (a) Checkpoint success rates (thin curves) and three-point moving averages (thick curves) through 16,000 training iterations. Stars indicate the highest observed checkpoint success rate for each solver. (b) Best-so-far success rates through 12,500 training iterations. The marked iterations indicate when each solver reaches the 97.0% and 98.0% success thresholds; percentage annotations report the reduction in training iterations relative to SA. (c) Average success versus Gray-code bit width (top) and suite-level changes in percentage points relative to the 14-bit reference (bottom). “Long” denotes LIBERO-10. The highlighted 7-bit configuration halves the number of binary source variables with a 0.25 percentage-point decrease in average success.
SmolVLA variant [ 41 ]
Spa.
Obj.
Goal
Long
Avg.
Official
90.0
96.0
92.0
71.0
87.25
Reproduction
87.2
97.4
92.4
87.2
91.05
Reproduction + Boltz-Flow
89.8
97.6
95.2
89.0
92.90
Table 8: Cross-backbone transfer to SmolVLA. The reproduced SmolVLA row is the controlled baseline; the official result is included as an external reference. All entries are success rates (%).
π0.5 variant
Spa.
Obj.
Goal
Long
Avg.
π0.5 [ 4 ]
96.4
98.8
95.8
87.6
94.65
+ A2A [ 23 ]
98.6
99.4
97.4
93.8
97.30
+ A2A + Boltz-Flow
98.8
100.0
97.6
95.4
97.95
Table 9: Incremental compatibility with Action-to-Action (A2A). All entries are success rates (%).
Task
π0.5 (OpenPI)
Boltz-Flow
Gain (pp)
Stack three bowls
90% (9/10)
100% (10/10)
+10
Bimanual block handover
40% (4/10)
50% (5/10)
+10
Place can next to pot
50% (5/10)
80% (8/10)
+30
Scan barcode
0% (0/10)
10% (1/10)
+10
Place medicine in tray
50% (5/10)
70% (7/10)
+20
Overall
46% (23/50)
62% (31/50)
+16
Table 10: Real-world success rates. Parentheses show successful/total trials. Gains are absolute improvements over OpenPI in percentage points (pp).