CTLink: A Text-Prompted Segmentation Model for Linking Radiology Report Findings to 3D Chest CT Scans
Authors: Mohammed Baharoon, Sung Eun Kim, Mahmoud Hussain Alabbad, Lucas Bijnens, Ali Piracha, Reem Alwasiah, Talal Yahyan, Abdulrahman Alamoudi, Mashael Alshehri, Rayan Alsager, Hannah Hancock, Anna M. Hunkemöller, Peter Youssef, Mona A. Alhammad, Afnan Aljumayan, Brecht Van Berkel, Eric Bijnens, Saud Alhussain, Maarten Steyvers, Rolf Symons, Bryan Eelen, Ayed Alaklubi, Maha Buraykan Alshammari, Amirah Fahad Alshammeri, Tomas Gilvydis, Ibrahim AlTurki, Monerah Almohideb, Ali Alburkani, Shahad Alhomaiani, Fatima Jabali, Abdulrhman Aljouie, Daesung Kim, Junha Im, Michael Moritz, Hassan R. Alomaish, Pranav Rajpurkar
Organizations: Department of Biomedical Informatics, Harvard Medical School, Boston, MA, USA · King Fahad Hospital, Al-Ahsa Health Cluster, Al Hofuf, Saudi Arabia · KU Leuven, Leuven, Belgium · Saint Louis University, St Louis, MO, USA · Medical Imaging Department, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, Riyadh, Saudi Arabia · Naval Medical Center Portsmouth, Portsmouth, VA, USA · Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany · Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), German Center for Lung Research (DZL), Hannover, Germany · Justus Liebig University Giessen, Giessen, Germany · Ras Tanura General Hospital, Ministry of Health, Ras Tanura, Saudi Arabia · Jessa Hospital, Hasselt, Belgium · King Fahad Specialist Hospital, Buraydah, Saudi Arabia · University Hospitals Leuven, Leuven, Belgium · Imelda Hospital, Bonheiden, Belgium · Prince Sultan Military Medical City, Riyadh, Saudi Arabia · University of Hail, Hail, Saudi Arabia · SSM Health, St Louis, MO, USA · King Saud University Medical City, Riyadh, Saudi Arabia · King Abdulaziz Specialist Hospital, Taif Health Cluster, Taif, Saudi Arabia · King Abdulaziz University Hospital, Jeddah, Saudi Arabia · Research and Innovation Institute, Ministry of Defense Health Services, Riyadh, Saudi Arabia · Yonsei University, Seoul, South Korea · Yonsei University College of Medicine, Seoul, South Korea
Radiology reports describe findings in text only, without visually marking them on the scan, so readers cannot directly see which abnormality each reported finding refers to. We introduce CTLink, a text-prompted 3D segmentation model that segments findings described in a chest CT report. CTLink was trained on 4123 noncontrast chest CT scans with 9547 segmented report findings, including ReXGroundingCTv2, a newly annotated dataset of 1134 scans and 1895 findings with every instance of each finding segmented. On the 200 ReXGroundingCT validation scans, CTLink achieved a hit rate of 0.816, an instance F1 score of 0.456, and a mean Dice score of 0.400, compared with 0.533, 0.175, and 0.234 for VoxTell, a publicly available text-prompted segmentation model (P < .001 for all). On the test set of the MICCAI 2026 ReXGrounding challenge, an ensemble of seven CTLink models achieved the highest hit rate (0.782) and instance F1 score (0.386) of all 48 participating teams. On 50 test scans segmented twice by independent radiologists, CTLink matched or exceeded inter-rater agreement. Diffuse non-focal findings remained the main limitation, partly because their extent is outlined inconsistently even between radiologists. The CTLink model weights are available at https://huggingface.co/rajpurkarlab/CTLink, and the dataset at https://huggingface.co/datasets/rajpurkarlab/ReXGroundingCT.
Figures & tables
Dataset
Scans
Findings
Focal
Non-focal
Annotation
Use
v1 training set*
2989
7652
6055
1597
Up to three instances
Training
v2 training set
1134
1895
1704
191
Every instance
Training
Validation set
200
381
329
52
Every instance
Ablation
Test set
300
582
509
73
Every instance
Challenge comparison
Table 1: Datasets. All scans are noncontrast chest CT scans from CT-RATE. ReXGroundingCTv2 adds the v2 training scans to ReXGroundingCT. *With the corrected masks released by Team 4 of the ReXGrounding challenge ( 24 ) . The original v1 training set has 2992 scans and 7687 findings.
Figure 1: Architecture of CTLink, which follows that of VoxTell ( 22 ) . Each finding sentence of the report is embedded by a frozen text encoder, and the chest CT scan is encoded by a U-Net encoder. A prompt decoder combines the sentence with the image features, and its output is fused with the decoder features at each resolution ( ⊗ ) to segment the finding.
Model
Instance F1
Dice
Hit Rate
VoxTell ( 22 )
0.175
0.234
0.533
+ v1 scans*
0.298 ↑ 0.123
0.353 ↑ 0.119
0.761 ↑ 0.228
+ v2 scans
0.316 ↑ 0.018
0.388 ↑ 0.035
0.793 ↑ 0.032
+ Oversampling of v2
0.310 ↓ 0.006
0.393 ↑ 0.005
0.803 ↑ 0.010
+ Larger input crops
0.328 ↑ 0.018
0.396 ↑ 0.003
0.801 ↓ 0.002
+ Longer training
0.373 ↑ 0.045
0.403 ↑ 0.007
0.824 ↑ 0.023
Table 2: Cumulative Ablation on the Validation Set. Data are values for the ReXGrounding challenge validation set. Rows are cumulative; arrows show the change from the row above ( green , increase; red , decrease). The first row is the published VoxTell model without fine-tuning. Oversampling of v2 draws the v2 scans three times as often as the v1 scans, larger input crops measure 192×256×256 instead of 1923 voxels, and longer training uses 75 000 instead of 50 000 iterations and an effective batch size of four instead of two. Hit rate is the proportion of findings with a Dice score of at least 0.1, Dice is the mean per-scan Dice score, and instance F1 matches connected components of the prediction one to one with the annotated reference instances. The v1 scans are the original ReXGroundingCT training scans, and the v2 scans are the training scans annotated exhaustively for this study (added in ReXGroundingCTv2). *With the corrected training masks.
Entry
Instance F1
Mean Dice
Hit Rate
CTLink without post-processing
0.264
0.369
0.773
CTLink
0.378
0.364
0.766
CTLink ensemble
0.386
0.373
0.782
Team 1 (winner)
0.341
0.375
0.768
Team 2
0.343
0.365
0.763
Team 3
0.334
0.362
0.765
Table 3: Comparison with the ReXGrounding Challenge Entries on the Test Set. Results for the other teams come from the ReXGrounding challenge paper ( 24 ) . CTLink is one network with the post-processing described in Materials and Methods (lobe restriction, non-focal threshold, emphysema gating, and removal of small components), and the CTLink ensemble averages seven CTLink models, with post-processing. Instance and hit precision and recall are in Table S2 .
Figure 2: Examples from the ReXGrounding challenge test set comparing the CTLink ensemble with the three top-ranked challenge entries ( 24 ) and VoxTell ( 22 ) . Numbers are Dice scores over the whole scan; the highest in each row is outlined and the second highest underlined.
Figure 3: Examples of successful CTLink ensemble segmentations on the ReXGrounding challenge test set. Numbers are Dice scores on the shown section.
Reference
Segmentation
Instance F1
Dice
Hit Rate
Reference masks
Second segmentation
0.417 (0.358, 0.478)
0.321 (0.264, 0.379)
0.760 (0.674, 0.839)
CTLink
0.399 (0.343, 0.461)
0.374 (0.316, 0.434)
0.823 (0.750, 0.893)
CTLink ensemble
0.412 (0.355, 0.473)
0.381 (0.325, 0.440)
0.854 (0.785, 0.919)
Second segmentation
CTLink
0.460 (0.394, 0.538)
0.381 (0.327, 0.435)
0.771 (0.697, 0.845)
CTLink ensemble
0.458 (0.387, 0.534)
0.380 (0.327, 0.434)
0.771 (0.697, 0.845)
Table 4: Comparison with a Second Radiologist Segmentation on 50 Test Scans. Data are values (95% CIs) for the 96 findings that the second segmentation also localized in the 50 ReXGrounding challenge test scans segmented twice in the inter-rater study of ReXGroundingCT ( 4 ) . Reference masks are those of the challenge, and the second segmentation was drawn independently by other radiologists in the inter-rater study. Reference refers to the masks each segmentation was scored against. All masks were scored with the challenge evaluator. Mean Dice score per scan.
Figure 4: Performance of CTLink by finding category and lesion size on the ReXGrounding challenge test set. (A) Hit rate and (B) mean Dice score of the findings in each focal and non-focal category, with the number of findings in parentheses. (C) Hit rate and mean Dice score of focal findings by reference volume, with the number of findings in parentheses. “Other non-focal” includes bronchial wall thickening and uncategorized non-focal findings. “All focal” also includes one pneumothorax and two “other” focal findings. Error bars show 95% CIs (2000 bootstrap replicates resampling scans).
Figure 5: Robustness analysis of CTLink without post-processing on the ReXGrounding challenge test set. (A) The same finding requested with the original sentence (under the ground truth), with synonyms, with abbreviations, and in free wording. (B) Findings in both lungs requested at once and for each lung separately. Images are in radiological orientation, with the patient’s right on the left of the image. Numbers are Dice scores over the whole scan.
Figure 6: Examples of findings that the CTLink ensemble missed on the ReXGrounding challenge test set. Each example shows the ground truth and the CTLink ensemble prediction on the same section. Numbers are Dice scores over the whole scan. Top left, on this section the ensemble segmented the nodules themselves, whereas the reference masks extend beyond them. Top right, it segmented the pleural fluid at the lung bases instead of the fluid in the fissures. Bottom right, it segmented the pneumothorax along the right lung instead of the air in the chest wall.
Figure S1: Instructions used to write the synonym, abbreviated, and freely reworded sentences.
Figure S2: Instructions used to write the left-lung and right-lung sentences of the findings that the model judged to involve both lungs (stated or implied, for example “bilateral”, “both lungs”, or lobes on both sides).
Figure S3: Instructions used to decide which lobes a finding involves and to write the lobe sentences.
v1 Masks
Instance F1
Dice
Hit Rate
Original
0.281
0.346
0.745
Corrected
0.298
0.353
0.761
Table S1: Original versus Corrected v1 Masks on the Validation Set. Data are values for the ReXGrounding challenge validation set. Both models were fine-tuned from VoxTell on the v1 scans only, with the same recipe and random seed, and differ only in the v1 masks: original (2992 scans, 7687 findings) or corrected (2989 scans, 7652 findings). Dice is the mean per-scan Dice score.
Instance
Hit
Entry
Precision
Recall
Precision
Recall
CTLink without post-processing
0.178
0.514
0.787
0.773
CTLink
0.336
0.432
0.789
0.766
CTLink ensemble
0.335
0.455
0.793
0.782
Team 1 (winner)
0.272
0.457
0.786
0.768
Team 2
0.280
0.443
0.766
0.763
Table S2: Precision and Recall of CTLink and the Challenge Entries on the Test Set. Data are values for the ReXGrounding challenge test set. Instance precision and recall match connected components of the prediction one to one with the annotated reference instances (match at Dice score ≥ 0.2; predicted components smaller than 10 voxels ignored). Hit recall is the proportion of findings with a Dice score of at least 0.1 (the hit rate), and hit precision is the proportion of findings with a nonempty prediction that were hits.
CTLink
CTLink Ensemble
Patients
Scans
Findings
Instance F1
Dice
Hit Rate
Instance F1
Dice
Hit Rate
Sex
Male
173
339
0.367
0.364
0.740
0.372
0.371
0.767
Female
127
243
0.395
0.364
0.802
0.408
0.374
0.802
Age (years)
< 40
142
249
0.413
0.396
0.799
0.419
0.402
0.815
Table S3: Performance by Patient Sex and Age on the Test Set. Data are values for the ReXGrounding challenge test set. Mean Dice score per scan.
Hit Rate
Dice
Instance F1
Edit
Findings
Original
Edited
Original
Edited
Original
Edited
Agreement
CTLink
Synonyms
297
0.771
0.768
0.370
0.366
0.385
0.382
0.95
Abbreviations
540
0.774
0.731
0.363
0.349
0.380
0.368
0.88
Free rewording
582
0.766
0.765
0.364
0.363
0.378
0.375
0.91
Left-right split
290
0.766
0.762
0.332
0.323
0.347
0.326
—
Table S4: Robustness Analysis: Effect of Phrasing. Data are for the ReXGrounding challenge test set. Each edit is compared with the original ReXGroundingCT sentence on the findings whose sentence the edit changed. The left-right split covers the 290 findings in both lungs, with the left-lung and right-lung predictions combined. The lobe split covers the 31 findings in two or more lobes of one lung, with the per-lobe predictions combined. Agreement is the median Dice score between the masks predicted for the original and the edited sentence. Mean Dice score per scan.
Siemens Medical Solutions USA, Inc., Malvern, PA, USA · The Ohio State University, Columbus, OH, USA · University of California, Los Angeles, Los Angeles, CA, USA +2