cs.AINov 23, 2026

CROSS-Calib: Selective Channel Calibration for Ultrasound Reconstruction

Authors: Tongxiao Hu, Junyu Zhou

Organizations: University of Oxford · Peking University

Abstract

Ultrasound imaging provides views of internal tissue in real time for medical diagnosis. However, ultrasound signals may be affected by interference, and correcting errors and removing transient interference while preserving valid echoes remains challenging. We propose CROSS-Calib, a channel recovery method that uses predictions from other channels as references for amplitude and phase calibration, while a gate using context selectively combines calibrated measurements with predicted echoes to retain usable samples and repair unreliable ones. On the in vivo test set, CROSS-Calib outperforms all baseline models under gain errors and transient interference, while phantom tests show that the model restores cyst contrast with echo widths of wire targets close to the clean reference. CROSS-Calib can perform channel calibration and selective repair before beamforming to improve echo usability and image quality.

Figures & tables

Explore similar work

Feb 26, 2026

IRSDE-Despeckle: A Physics-Grounded Diffusion Model for Generalizable Ultrasound Despeckling

Ultrasound imaging is widely used for real-time, noninvasive diagnosis, but speckle and related artifacts reduce image quality and can hinder interpretation. We present a diffusion-based ultrasound despeckling method built on the Image Restoration Stochastic Differential Equations framework. To enable supervised training, we curate large paired datasets by simulating ultrasound images from speckle-free magnetic resonance images using the Matlab UltraSound Toolbox. The proposed model reconstructs speckle-suppressed images while preserving anatomically meaningful edges and contrast. On a held-out simulated test set, our approach consistently outperforms classical filters and recent learning-based despeckling baselines. We quantify prediction uncertainty via cross-model variance and show that higher uncertainty correlates with higher reconstruction error, providing a practical indicator of difficult or failure-prone regions. Finally, we evaluate sensitivity to simulation probe settings and observe domain shift, motivating diversified training and adaptation for robust clinical deployment.
Nov 23, 2026

XFreq: Geometry-Aligned Cross-View Residual Learning for Sparse 3D Ultrasound Reconstruction

Three-dimensional (3D) ultrasound provides valuable volumetric context for anatomical assessment, motivating reconstruction from widely available two-dimensional (2D) slices. Sparse slices leave much of the volume unobserved, even when their acquisition poses are known. Existing methods interpolate observed intensities or incorporate learned 2D image features into 3D reconstruction, but their complementary roles in predicting smooth structure and residual details remain less explored. We introduce XFreq, a geometry-aligned framework for sparse 3D ultrasound reconstruction. It uses known slice poses and finite footprints to query 2D image features at 3D locations, complementing splatted intensities and sampling geometry. A low-frequency decoder predicts a smooth 3D field from the splat representation, while a high-frequency decoder additionally incorporates the queried 2D features to predict residual details. A learned gating module regulates the residual contribution based on geometry and cross-slice feature variation. We evaluate XFreq on an in-house fetal brain dataset and the public CETUS cardiac dataset, using slices resampled from 3D ultrasound volumes and fivefold cross-validation. Among the compared methods, XFreq achieves the highest PSNR and SSIM in most settings across both datasets, reaching 26.82 dB PSNR on CETUS with 32 input slices. Ablation studies further show the contributions of local feature querying, geometric cues, and residual prediction, with gains generally increasing as more input slices are used. Our findings highlight the value of geometry-aligned cross-view feature integration for reconstructing 3D ultrasound volumes from sparse 2D slices.
Sep 23, 2026

Physics-Guided Multi-Objective Deep Learning for Ultrasound RF Data Interpolation in Resource-Constrained Imaging

Ultrasound imaging increasingly targets portable, point-of-care, and wearable settings where constraints on power, bandwidth, and hardware complexity often necessitate sparse data acquisition in spatiotemporal scanning. However, image reconstruction using the sparse data can introduce insufficient phase information in coherent beamforming process, resulting in grating-lobe artifacts that degrade imaging contrast resolution. We present a physics-guided, data-driven framework for sparse-to-dense radio-frequency (RF) reconstruction that aligns training with downstream image formation. Our approach trains an end-to-end interpolation network using a hybrid supervision scheme that combines an RF-domain and a beamforming-domain loss with exponential moving average (EMA) to stabilize the multi-objective training. To improve generalization under variable acquisition layouts, we also introduce a random-skip masking strategy that varies sparsity patterns during training so a single model can handle diverse decimation factors and irregular channel configurations. We evaluate the framework on a held-out test set using the mean structural similarity index measure (SSIM) between reconstructed and ground-truth beamformed images. Across decimation factors ×2\times 2 to ×13\times 13, the best-performing configuration maintains mean SSIM around 0.95. Overall, the results show consistent gains in RF reconstruction and post-beamforming image quality across diverse acquisition conditions. This approach enables robust, high-quality ultrasound imaging at resource-constrained settings by allowing more sparse scanning in spatiotemporal domain.