cs.CVNov 23, 2026

E-Waste-Bench: A Large-Scale Benchmark for Visual Triage of Data-Center Hardware

Authors: Nader Lobandi, Mohammad Mehdi Hosseini, Lombe Chileshe, Mohammad Mahoor

Organizations: University of Denver, 2199 S. University Blvd., Denver, CO 80208

Abstract

Retired data-center hardware can often be refurbished or resold, but triage demands more than object categories. A model must tell visually similar parts apart, judge condition under damage and occlusion, and read the printed part number. We audit nine public e-waste collections. They cover mostly consumer devices (only 10% of images are labeled as a data-center part), label neither condition nor printed text, and contain 42% exact or augmented duplicates. We introduce E-Waste-Bench, 328K photographs drawn from 762K deduplicated images and labeled for class (24 classes), granularity, condition and printed text. Images come from those collections and the web, where a recipe-based crawler works beside an agent built on an open-weight vision-language model. The agent vets new sources and reads sites the crawler cannot parse, and both are steered toward under-represented classes. Training labels are model-made, splits follow near-duplicate groups, and human annotators label a test set of nearly 10,000 images. We benchmark classification, condition, detection, text perception and cross-dataset transfer. On this test set, a ConvNeXt-T trained on E-Waste-Bench reaches 64.3% top-1, against 31.5% with the public collections alone. Near-duplicate leakage inflates top-1 by 3.0 points under model-made test labels but by less than 0.1 under human labels, so model-labeled benchmarks need group splits. Accuracy falls to 42.1% on marketplace and auction photographs, the closest proxy for hardware leaving service. Data and code will be released.

Figures & tables

Appendix figures & tables1 asset

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Nov 23, 2026

Do Waste Classifiers Recognise Items They Have Never Seen? Object-Disjoint Evaluation on Household and Medical Waste

Automatic waste classification supports source separation, which enables recycling and keeps hazardous medical items out of household waste. Waste classification studies often report near-perfect accuracy on random image splits, which put photographs of one item in both training and test sets. To measure how well classifiers recognise items they have never seen, we built BanglaWaste-23, with 4,160 images of 172 objects in 23 household and medical waste classes from Bangladesh. Every image also records which physical item it shows. We evaluated 11 ImageNet-pretrained models and two models trained from scratch (a compact custom network and MobileNetV3-L) using object-disjoint five-fold cross-validation and a random split. On unseen objects, the best pretrained model reached a macro-averaged F1 score of 98.8%, and six models were statistically tied. The random split overstated from-scratch accuracy by 15 to 19 percentage points. The from-scratch models also missed 11 to 13% of medical items, against under 1% for pretrained models. On a second dataset from Dhaka, pretrained accuracy fell by 15 to 22 points. Classifiers should therefore be evaluated on unseen objects, with random-split results read as an upper bound. The data are on Zenodo and the code at https://github.com/saadbaust/BanglaWaste-23.
Mar 28, 2026

Evaluating Large and Lightweight Vision Models for Irregular Component Segmentation in E-Waste Disassembly

Precise segmentation of irregular and densely arranged components is essential for robotic disassembly and material recovery in electronic waste (e-waste) recycling. This study evaluates the impact of model architecture and scale on segmentation performance by comparing SAM2, a transformer-based vision model, with the lightweight YOLOv8 network. Both models were trained and tested on a newly collected dataset of 1,456 annotated RGB images of laptop components including logic boards, heat sinks, and fans, captured under varying illumination and orientation conditions. Data augmentation techniques, such as random rotation, flipping, and cropping, were applied to improve model robustness. YOLOv8 achieved higher segmentation accuracy (mAP50 = 98.8%, mAP50-95 = 85%) and stronger boundary precision than SAM2 (mAP50 = 8.4%). SAM2 demonstrated flexibility in representing diverse object structures but often produced overlapping masks and inconsistent contours. These findings show that large pre-trained models require task-specific optimization for industrial applications. The resulting dataset and benchmarking framework provide a foundation for developing scalable vision algorithms for robotic e-waste disassembly and circular manufacturing systems.
Jun 14, 2026

EcoBin: A Two-Stage Deep Convolutional Neural Network for Contamination-Aware Waste Classification

Waste classification models have become highly accurate at sorting waste, often exceeding 95% on benchmark datasets. However, these models fail to account for contamination in recyclable waste. We present EcoBin, a two-stage deep convolutional neural network that classifies household waste by its disposal pathway and that explicitly accounts for contamination. The first stage is a base waste classifier built on an EfficientNetV2-S backbone that assigns each of the thirty waste categories in our dataset to one of four disposal pathways. The second stage is a contamination classifier that inspects any item routed toward recycling and overrides the decision to garbage when contamination is detected. Because no public dataset of contaminated recyclables exists, we synthesize one by segmenting images of clean recyclable objects with a U2-Net model and compositing realistic contamination textures onto their surfaces. The first stage achieves 87.42% test accuracy and a 96.13% pathway-adjusted accuracy. Meanwhile, the contamination stage distinguishes clean from contaminated items with a 0.99 ROC-AUC. On a test set of contaminated recyclables, the complete pipeline routes 24 of 25 items correctly, compared with only 1 of 25 for the base classifier alone. A McNemar's test confirms that the improvement contributed by the contamination stage is statistically significant (p < 0.001).