Specialist medical vision-language models (VLMs) are strong within their specialties but hard to unify: their training data are often private, and independently developed specialists cannot be assumed to share an architecture. Deploying these large models separately is costly. We present HuluOPD, an on-policy distillation recipe that unifies heterogeneous specialists into one lightweight VLM using only unlabeled prompts, without requiring reference answers or the specialists' training data. The lightweight model answers each prompt, and the specialist of the prompt's modality supervises its response; a continuation-aligned cross-tokenizer loss makes this possible even when they differ in architecture and tokenizer. We apply HuluOPD to five specialists, for ultrasound, pathology, optical coherence tomography, fundus photography, and dental imaging. To distill and evaluate them, we build HuluOPDCorpus, 914k unlabeled prompts, and HuluOPDBench, 47k held-out test items, from over 90 public datasets, and score all models under one protocol on 132k test items, including third-party benchmarks. A single model with 10% of the five specialists' combined parameters retains 94% of their question-answering performance, and one with 2% retains 89%. To our knowledge, this is the first demonstration of unifying heterogeneous medical specialist VLMs without requiring their training data or a shared architecture.
Figures & tables
Figure 1: Three ways to serve many specialties, and our results. (a) One large specialist per specialty, trained on private data. (b) One generalist trained on pooled labeled data (arrows are illustrative). (c) HuluOPD distills heterogeneous specialists into one lightweight student with unlabeled prompts only. Bottom: the two unified students on 13 VQA benchmarks ( Tab. 2 ).
Figure 2: HuluOPDBench and HuluOPDCorpus. Outer arcs: the four task groups; colored ring: imaging modality; bars: number of items per sub-task (log scale). Sources: Appendix Tabs. 8 and 8 ; dental imaging is evaluated on the DentVLM benchmarks.
Figure 3: Overview of HuluOPD. (1) A router sends each prompt to the specialist of its modality (here, OCT), which re-tokenizes the student’s response; orange tokens are split alike by both tokenizers, gray ones differently. (2) Candidates are paired by the text they complete ( e.g . , teacher us + en with student usen ); matched ones (orange) enter KL, unmatched ones (gray) a sorted-probability term W .
HuluMed - 4B
Qwen3.5 - 0.8B
Benchmark
Task
Teacher
Base
+ HuluOPD
Base
+ HuluOPD
Ultrasound
HuluOPDBench
VQA
73.44
47.51
64.00 +16.49
45.80
60.31 +14.51
Gen
89.36
83.40
89.01 +5.61
81.29
88.87 +7.58
OmniMedVQA
VQA
97.28
75.41
83.43 +8.02
66.85
78.24 +11.39
U2 - BENCH
VQA
58.07
40.83
52.28 +11.45
40.46
50.59 +10.13
Table 1: Single-specialist distillation: each student is distilled from each modality’s teacher separately. Base: before distillation; + HuluOPD: after the full recipe; green: gain over Base in points. Clin.: DentVLM - Clinical - Bench. Metrics as in Sec. 4.1 , ×100 ; Avg.: over all VQA and VQA - MS items.
Open Generalists
HuluMed - 4B
Qwen3.5 - 0.8B
Modality
Benchmark
Task
HealthGPT [-2.5pt]Pro - 4B [ 16 ]
MedGemma [-2.5pt]1.5 - 4B [ 30 ]
Lingshu [-2.5pt]7B [ 43 ]
HuluMed [-2.5pt]30A3 [ 37 ]
Teacher
Base
+ HuluOPD
Base
+ HuluOPD
Ultrasound
HuluOPDBench
VQA
49.07
42.46
47.27
52.72
73.44
47.51
60.65 +13.14
45.80
58.03 +12.23
Gen
83.19
81.96
84.04
83.15
89.36
83.40
88.70 +5.30
81.29
88.14 +6.85
OmniMedVQA
VQA
74.72
61.03
68.12
82.09
97.28
75.41
84.79 +9.38
66.85
76.35 +9.50
U2 - BENCH
VQA
41.30
35.45
43.48
49.67
58.07
40.83
52.17 +11.34
40.46
47.31 +6.85
Table 2: Unified multi-specialist distillation: one student is distilled from all five teachers. Open Generalists: released medical VLMs, evaluated as released under the same protocol. Bold: best among generalists and students. Otherwise as in Tab. 1 .
Figure 4: What the students take from their teachers. (a) Accuracy before (hollow) and after HuluOPD (filled), on items the teacher gets right (97,001) and wrong (27,348). (b) For each of the 87 source datasets with at least 100 items, the student’s gain over its base model against the teacher’s lead over that model. Solid lines: least-squares fits through the origin; dashed line: student equals teacher.
Figure 5: Case study: a typical HuluOPDBench item. Yellow marks the key findings where a model reports them, dark red where it denies them; […]: omitted text.
Method
On-policy
Multi
Hetero.
VLM
Medical
Label-free
ULD [ 4 ]
×
×
✓
×
×
✓
GKD [ 1 ]
✓
×
×
×
×
✓
GOLD [ 25 ]
✓
×
✓
×
×
✓
Med - OPD [ 26 ]
✓
×
×
✓
✓
×
MOPD [ 19 ]
✓
✓
×
×
×
✓
OPOD [ 46 ]
✓
✓
×
✓
×
×
Table 3: Comparison with representative distillation methods. Multi: several teachers; Hetero.: teachers may differ from the student in architecture and tokenizer; Label-free: no answers.
Appendix figures & tables7 assets
Supplementary material from the paper’s appendix.
Appendix
Modality
DG
REC
DET
GEN
Total
HuluOPDCorpus (prompts)
Ultrasound
75,626
162,334
1,647
60,393
300,000
Pathology
62,684
174,649
64,877
73,403
375,613
OCT
74,727
11,662
212
207
86,808
Fundus photography
71,800
18,355
11,425
7,308
108,888
Dental imaging
31,478
–
11,557
–
43,035
Appendix
Table 5: Composition of HuluOPDCorpus and HuluOPDBench by modality and task group. DG: diagnosis and grading; REC: recognition; DET: detection and localization; GEN: report and caption generation.
Model
Teacher for
Vision encoder
Language model
Vocab.
Params
Qwen3.5 - 9B †
Ultrasound, pathology
Qwen3.5 ViT (0.46B)
Qwen3.5 - 9B
248,077
9.41B
InternVL3.5 - 8B †
OCT, fundus photography
InternViT (0.30B)
Qwen3-8B
151,679
8.53B
DentVLM [ 61 ]
Dental imaging
Qwen2-VL ViT (0.68B)
Qwen2-7B
151,657
8.29B
HuluMed - 4B [ 37 ]
– (student)
Qwen3-VL ViT (0.42B)
Qwen3-4B
151,669
4.44B
Qwen3.5 - 0.8B [ 70 ]
– (student)
Qwen3.5 ViT (0.10B)
Qwen3.5 - 0.8B
248,070
0.85B
Appendix
Table 6: Teachers and students. † Fine-tuned by us. Params: total parameters, with the vision encoder’s share in parentheses. Vocab.: tokenizer entries, including special tokens.
Single-specialist
Unified
Modality
Warm-up
OPD
Warm-up
OPD
Ablation
Ultrasound
50k
300,000
23k
98,980
10k
Pathology
50k
375,613
23k
98,980
10k
OCT
20k
86,808
10k
43,035
10k
Fundus photography
20k
108,888
14k
60,249
10k
Dental imaging
10k
43,035
10k
43,035
10k
Appendix
Table 9: Prompts used in each stage , by modality. OPD: on-policy distillation; single-specialist OPD uses all HuluOPDCorpus prompts of the modality. Ablation: loss ablation of Sec. 4.6 .
Setting
Warm-up
On-policy distillation
Responses
from the teacher; greedy decoding, repetition penalty 1.05
sampled by the student; temperature 0.7, top- p 0.8, top- k 20, repetition penalty 1.08
Response length
at most 2,048 new tokens (768 for DentVLM)
at most 512 new tokens (1,024 in the unified run)
Trained parameters
language model and projector; vision encoder frozen
all, including the vision encoder
Epochs
1
2
Global batch
32 (16 for dental imaging)
64
Learning rate
10−5 for HuluMed - 4B; 2×10−5 for Qwen3.5 - 0.8B ( 10−5 for its projector)
2×10−7
Appendix
Table 10: Training settings of the two stages of HuluOPD. Exceptions are given in parentheses.
HuluMed - 4B
Qwen3.5 - 0.8B
Group
Items
Teacher
Base
+ HuluOPD
Base
+ HuluOPD
DG
53,958
69.28
48.70
65.40 +16.70
40.39
61.92 +21.53
REC
52,840
84.61
66.24
77.59 +11.35
62.60
72.37 +9.77
DET
19,994
82.32
62.96
80.65 +17.69
65.36
78.87 +13.51
GEN
5,073
87.76
83.16
86.53 +3.37
81.63
86.12 +4.49
Appendix
Table 11: Unified students by task group , over all benchmarks. Task groups as in Tab. 5 ; DG, REC, and DET are scored as the Avg. of Tab. 2 , GEN by BERTScore; green: gain over Base.
Modality
Benchmark
Items
Evaluated
Left out
Ultrasound
OmniMedVQA - US [ 31 ]
10,976
ultrasound questions
other imaging modalities
U2 - BENCH [ 49 ]
3,513
disease diagnosis; view recognition and assessment; report generation; caption generation
lesion localization; organ detection; keypoint detection; clinical value estimation; plane-quality questions on ACOUSLIC-AI; fetal-orientation questions on FPUS23
Pathology
PathMMU [ 77 ]
8,202
multiple-choice questions whose images are publicly available
questions whose images are not available
PathVQA [ 29 ]
2,681
yes/no (1,552) and open-ended (1,129) questions on the 404 microscopy images of the test split
gross-pathology photographs; training and validation splits
coarse modality perception (L1a); lesion analysis (L3); ultra-widefield images (TOP and part of DeepDRiD); MMC-AMD
Appendix
Table 12: Third-party benchmarks : the parts we evaluate and the parts we leave out. Items: test items evaluated, after the check of Appendix A . Task names follow each benchmark.