Applications such as ticket routing and incident triage need decisions that software can act on. Decision models provide these outputs through explicit types for choices, binary judgments, and policy scores. We evaluate the accuracy, output validity, and request latency of eleven configurations on 1,000 English and Chinese cases across nine task suites. StartLux Instant achieves 95.3% overall accuracy, returns valid outputs on all 1,000 cases, and has a median request latency of 0.084 s. It reaches 99.4% on classification and routing and selects the correct response on all 100 tool-selection cases. The highest overall accuracy among the evaluated configurations is 97.1%. These results show how a typed decision service can support fast, programmatic decisions and why its suitability depends on task-specific errors and latency requirements.
Figures & tables
Suite
Task
Cases
Sources
S01
Classification and routing
160
BANKING77 (80), TNEWS (80)
S02
Semantic relations
160
OCNLI (100), PAWS-X (60)
S03
Document evidence
160
BoolQ (60), C3 dialogue (30), C3 long (30), ContractNLI (40)
S04
Product relevance
150
ESCI (150)
S05
Tool-response selection
100
When2Call multiple-choice subset (100)
S06
Numerical reasoning
50
AQuA (50)
Table 1: The 1,000-case benchmark: task coverage, case counts, and source resources. Source splits are listed in Appendix A .
Abbreviation
Configuration
Decision path and reasoning control
SL-I
StartLux Instant
Native readout; thinking disabled
SL-A
StartLux AutoThink
Native readout; gated thought, gate 0.9
SL-N
StartLux AutoThink (never)
Same AutoThink checkpoint; thought disabled
Clef
Clef 27B
Native joint schema head; no answer generation
Q35-F
Qwen3.5 fast
Generated JSON; thinking disabled
Q35-T
Qwen3.5 thinking
Generated JSON; thinking enabled
Table 2: Eleven tested configurations. “GPT” denotes the service identifier gpt-6-sol . Full repositories, revisions, and controls appear in Appendix B .
Configuration
Correct
Acc. (%)
95% interval
Discrete
Rule
Invalid
GPT medium
971
97.10
[96.10, 98.00]
921/950
50/50
0
Qwen3.8 medium
965
96.50
[95.40, 97.60]
915/950
50/50
0
StartLux AutoThink
959
95.90
[94.60, 97.10]
909/950
50/50
0
StartLux Instant
953
95.30
[94.00, 96.50]
903/950
50/50
0
StartLux AutoThink (never)
944
94.40
[93.00, 95.70]
894/950
50/50
0
JEV 1.14.0
938
93.80
[92.40, 95.20]
888/950
50/50
0
Table 3: Overall accuracy on the 1,000-case benchmark. Discrete and Rule report correct counts for each question type. A rule score is rounded to the nearest grade. Invalid counts cover all cases.
Figure 1: Overall accuracy with 95% stratified grouped bootstrap intervals. The left panel shows the full scale; the right panel enlarges the observed range. Colors distinguish StartLux, Clef, and Qwen3.5 (blue), Qwen3.8 (teal), and hosted services (ochre).
Configuration
Correct/950
Acc. (%)
95% interval
Rule MAE
MAE 95% interval
StartLux Instant
903
95.05
[93.68, 96.32]
0.0004
[0.0003, 0.0005]
StartLux AutoThink
909
95.68
[94.32, 96.95]
0.0030
[0.0024, 0.0036]
StartLux AutoThink (never)
894
94.11
[92.63, 95.47]
0.0030
[0.0024, 0.0036]
Clef 27B
858
90.32
[88.42, 92.00]
0.0955
[0.0766, 0.1156]
Qwen3.5 fast
747
78.63
[76.21, 81.05]
0.0400
[0.0000, 0.1200]
Qwen3.5 thinking
877
92.32
[90.63, 94.00]
0.0600
[0.0000, 0.1800]
Table 4: Discrete-decision accuracy and rule-score MAE. Accuracy intervals are in percent; MAE and its interval are on the 0–3 scale.
A
B
A only
B only
Difference (pp)
95% interval (pp)
Q38-M
Q38-F
196
13
+18.30
[+16.00, +20.80]
Q38-M
Q35-T
52
13
+3.90
[+2.30, +5.50]
Q38-F
Q35-F
75
89
-1.40
[-3.80, +1.00]
Q38-M
GPT-M
17
23
-0.60
[-1.80, +0.60]
Q38-M
SL-A
31
25
+0.60
[-0.90, +2.10]
SL-A
SL-N
21
6
+1.50
[+0.60, +2.50]
Table 5: Selected paired accuracy comparisons. Difference is A minus B in percentage points. “A only” and “B only” count discordant cases. Appendix D includes every pair.
Figure 2: Selected paired accuracy differences with 95% bootstrap intervals. Shared resampling preserves the case pairing.
Figure 3: Accuracy on the eight discrete task suites. The different column sizes define the micro-average; an unweighted macro-average is supplied in Appendix C .
Configuration
S01
S02
S03
S04
S05
S06
S07
S08
StartLux Instant
99.4
93.1
98.1
91.3
100.0
88.0
92.9
92.0
StartLux AutoThink
98.1
93.1
98.8
93.3
99.0
96.0
91.4
94.0
StartLux AutoThink (never)
98.8
93.1
98.8
92.7
98.0
78.0
92.9
88.0
Clef 27B
99.4
88.1
96.2
91.3
90.0
66.0
87.1
83.0
Qwen3.5 fast
86.2
90.0
91.2
72.7
72.0
24.0
84.3
67.0
Qwen3.5 thinking
95.0
93.1
90.0
89.3
99.0
92.0
91.4
89.0
Table 6: Per-suite discrete accuracy (%). Suite definitions and sizes are in Table 1 .
Configuration
MAE
MAE 95% interval
Rule
Clean
Attack
Both
StartLux Instant
0.0004
[0.0003, 0.0005]
50/50
35/35
30/35
30/35
StartLux AutoThink
0.0030
[0.0024, 0.0036]
50/50
35/35
29/35
29/35
StartLux AutoThink (never)
0.0030
[0.0024, 0.0036]
50/50
35/35
30/35
30/35
Clef 27B
0.0955
[0.0766, 0.1156]
50/50
35/35
26/35
26/35
Qwen3.5 fast
0.0400
[0.0000, 0.1200]
49/50
35/35
24/35
24/35
Qwen3.5 thinking
0.0600
[0.0000, 0.1800]
49/50
34/35
30/35
29/35
Table 7: Rule scoring (50 cases) and robustness (35 pairs, 70 items). Rule counts correct rounded grades. Clean and Attack count correct original and perturbed items. Both counts pairs with two correct answers.
Figure 4: Left panel shows accuracy on original (open) and perturbed (filled) items from 35 pairs. Lines connect the two observed accuracies. Right panel shows MAE on 50 rule cases with 95% grouped bootstrap intervals.
Configuration
P50 (s)
P95 (s)
Max. (s)
Total (min)
Invalid
StartLux Instant
0.084
0.318
1.120
2.12
0
StartLux AutoThink
0.120
8.605
117.962
38.76
0
StartLux AutoThink (never)
0.070
0.177
0.767
1.56
0
Clef 27B
0.102
0.217
0.672
1.90
0
Qwen3.5 fast
0.278
0.444
0.976
4.99
0
Qwen3.5 thinking
51.993
94.163
173.335
825.01
11
Table 8: Request waits over 1,000 cases. Total is cumulative wait, including failed requests.
Figure 5: Median (circle) and P95 (vertical tick) request waits, on a logarithmic scale. Labels above circles give medians in seconds.
Figure 6: Overall accuracy against cumulative request wait. The left panel enlarges the high-accuracy region; the right panel shows the full accuracy scale. Labels use the abbreviations in Table 2 .
Table 9: Source case counts, data splits, and resource links. All cases are subsets or adaptations.
Configuration
Text (850)
Image (100)
No robust (880)
Macro (8)
StartLux Instant
95.41
92.00
95.23
94.35
StartLux AutoThink
95.88
94.00
96.02
95.47
StartLux AutoThink (never)
94.82
88.00
94.20
92.52
Clef 27B
91.18
83.00
90.57
87.65
Qwen3.5 fast
80.00
67.00
78.18
73.43
Qwen3.5 thinking
92.71
89.00
92.39
92.36
Appendix
Table 10: Discrete-accuracy sensitivity views (%). Denominators are shown in the headings. Macro is the unweighted average over eight discrete suites.
Configuration
Input tokens
Output tokens
Reasoning tokens
Native triggers
Usage
StartLux Instant
342491
0
–
0/1000
1000/1000
StartLux AutoThink
342491
54918
–
359/1000
1000/1000
StartLux AutoThink (never)
342491
0
–
0/1000
1000/1000
Clef 27B
445364
0
–
–
1000/1000
Qwen3.5 fast
431001
8343
0
–
1000/1000
Qwen3.5 thinking
444001
2670281
2638718
–
1000/1000
Appendix
Table 11: Endpoint-reported usage totals over 1,000 cases per configuration. Usage is the number of cases with usage metadata; Native triggers is the number of cases triggering a native thought. Reasoning tokens are shown only where explicitly reported.
A
B
Both
A only
B only
Neither
Δ (pp)
95% interval (pp)
SL-I
SL-A
937
16
22
25
-0.60
[-1.80, +0.50]
SL-I
SL-N
930
23
14
33
+0.90
[-0.30, +2.00]
SL-I
Clef
884
69
24
23
+4.50
[+2.70, +6.30]
SL-I
Q35-F
778
175
18
29
+15.70
[+13.30, +18.00]
SL-I
Q35-T
892
61
34
13
+2.70
[+0.80, +4.50]
SL-I
GPT-M
933
20
38
9
-1.80
[-3.20, -0.40]
Appendix
Table 12: All 55 paired accuracy comparisons on 1,000 cases. Abbreviations are defined in Table 2 . Intervals are unadjusted.