cs.CVNov 25, 2026

Structured Noise Diffusion for Echocardiography Haze Removal

Authors: Zike Luo, Hao Li, Mengxiao Wang, Qingya Li, Ching-Hui Sia, Lei Li

Organizations: Department of Biomedical Engineering, National University of Singapore, Singapore. · Department of Medicine, National University of Singapore, Singapore. · Department of Cardiology, National University Heart Centre Singapore, Singapore

Abstract

Echocardiographic images are frequently degraded by spatially structured haze artifacts that obscure anatomical boundaries and hinder clinical analysis. Conventional diffusion models typically employ pixel-independent Gaussian noise, limiting their ability to represent localized ultrasound haze. In this study, we propose a structure-informed diffusion framework that explicitly models ultrasound haze as an accumulation of localized Gaussian components constrained by the ultrasound fan geometry. The forward process generates spatially correlated corruption by sampling component locations and scales, providing a formulation that better reflects the spatial characteristics of real echo artifacts. During reverse restoration, a dual-head network predicts an anchor probability map and Gaussian scale parameters to progressively remove structured artifacts while reducing the center bias associated with direct coordinate regression. We evaluated the framework on the public DehazingEcho2025 benchmark and two private clinical datasets, without retraining or fine-tuning on either private cohort. Our method achieved the highest mean generalized contrast-to-noise ratio across all three datasets, reaching 0.715±0.0900.715 \pm 0.090 on the public benchmark while preserving tissue edges.

Figures & tables

Explore similar work

Aug 11, 2026

HNDiff: Haze-Noise Diffusion for Image Dehazing

Existing diffusion-based methods have recently made significant progress in image dehazing. However, they typically neglect the physics of haze formation and reconstruct clean images from pure Gaussian noise, thereby limiting their restoration potential. To address this issue, we propose Haze-Noise Diffusion (HNDiff), a novel diffusion framework that embeds the atmospheric scattering model as an inductive bias. By grounding diffusion in physical principles, HNDiff ensures that the restoration aligns more closely with underlying mechanisms of haze formation. In its forward process, we introduce joint haze-noise diffusion with a haze-aware noise scheduler, which progressively adds both haze and noise to an image. Essentially, the scheduler adapts noise levels according to haze density, meaning that regions with heavier haze receive stronger noise injection to encourage content generation, while clearer regions receive lighter noise to better preserve details, which directly links the forward degradation process with the physics of haze. In the reverse process, we then derive a physically consistent dehazing-denoising process that simultaneously removes haze and noise to restore a clean image in a manner aligned with the forward degradation process. To further enhance practicality, we propose Latent HNDiff, which compiles clean latent priors that can be seamlessly integrated into existing dehazing networks to boost performance. Extensive experiments show that our work significantly improves leading dehazing backbones and achieves state-of-the-art results on benchmark datasets. The project page is available at https://jin-ting-he.github.io/HNDiff .
Feb 26, 2026

IRSDE-Despeckle: A Physics-Grounded Diffusion Model for Generalizable Ultrasound Despeckling

Ultrasound imaging is widely used for real-time, noninvasive diagnosis, but speckle and related artifacts reduce image quality and can hinder interpretation. We present a diffusion-based ultrasound despeckling method built on the Image Restoration Stochastic Differential Equations framework. To enable supervised training, we curate large paired datasets by simulating ultrasound images from speckle-free magnetic resonance images using the Matlab UltraSound Toolbox. The proposed model reconstructs speckle-suppressed images while preserving anatomically meaningful edges and contrast. On a held-out simulated test set, our approach consistently outperforms classical filters and recent learning-based despeckling baselines. We quantify prediction uncertainty via cross-model variance and show that higher uncertainty correlates with higher reconstruction error, providing a practical indicator of difficult or failure-prone regions. Finally, we evaluate sensitivity to simulation probe settings and observe domain shift, motivating diversified training and adaptation for robust clinical deployment.
Jun 8, 2026

Echo-DM: Ultrasound Marker Removal via Conditional Latent Diffusion and Region-Aware Fusion

Clinical ultrasound images often contain artificial markers, such as measurement calipers and text, to assist diagnostic interpretation and comparison. However, these markers can introduce shortcut bias in downstream automated analysis, encouraging deep learning models to rely on marker-related cues rather than clinically meaningful anatomy. Existing marker removal methods are either mask-dependent and vulnerable to error propagation, or mask-free deterministic restorers that may over-smooth ultrasound texture and perturb unaffected background regions. To address these challenges, we present Echo-DM, a framework for ultrasound marker removal via conditional latent diffusion and region-aware fusion. Echo-DM follows a common encoder-diffusion-decoder pipeline, where a DiT-based conditional latent diffusion network performs global restoration and a region-aware fusion module enforces preservation-aware image-space refinement under end-to-end mask-free inference. Building on this fixed core design, we further instantiate Echo-DM-V and Echo-DM-R with VAE-based and RAE-based latent modules, respectively, which demonstrates that the Echo-DM architecture is compatible with diverse latent-module instantiations. Extensive experiments on Echo-PAIR, a large-scale paired clinical ultrasound dataset, demonstrate superior marker removal and strong anatomical fidelity compared with representative two-stage baselines, while providing favorable quality--efficiency trade-offs across deployment settings. Data, code and models will be released at https://github.com/MiliLab/Echo-DM.