cs.HCNov 25, 2026

Decision-Aligned Value Learning for Selective Adoption of EEG Fusion in Human-Robot Collaboration

Authors: Xinjia Yu, Jing Yang, Yang Zhou, Tielin Shi, Tao Cheng

Organizations: School of Mechanical Science and Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074, China. · School of Urban Transport and Logistics, Shenzhen Technology University, 3002 Lantian Road, Shenzhen 518118, China.

Abstract

Electroencephalography (EEG) captures neural activity associated with human perception and decision-making. It provides human-robot collaboration (HRC) systems with measurable evidence for event recognition, situation assessment, and action preparation. External sensing cannot easily provide such evidence. However, the quality and complementarity of this evidence vary across samples, and existing EEG fusion methods do not explicitly determine when EEG improves a prediction. We therefore framed selective EEG use as a sample-wise incremental-value estimation problem and proposed Value Estimation and Constraint-Aware Triage for Adoption (VECTA). VECTA separates the generation of an EEG-informed Fusion prediction from the decision about whether it should replace the existing Base prediction. The framework uses system gain to quantify the loss reduction from Base to Fusion and matching gain to assess whether benefits arise from sample-matched EEG. A signed-value learner estimates system gain from decision-time evidence and prioritizes high-value Fusion outputs under budget constraints. Cross-subject evaluations on three HRC datasets showed that matched Fusion outperformed shuffled controls. Estimated gains tracked realized gains, with Spearman correlations of 0.347-0.612 and positive-gain areas under the receiver operating characteristic curve (AUROCs) of 0.708-0.842. Under budget constraints, VECTA reduced Brier loss and harmful Fusion adoption and achieved the highest mean normalized AUBC across three datasets among the selective-decision methods evaluated. Validation on three external multi-modal datasets showed that VECTA could be applied directly as a post-hoc decision layer to task-specific predictors without retraining. These results show that selective Fusion adoption can translate the uneven utility of EEG into system-level gains.

Figures & tables

Explore similar work

Mar 7, 2026

Aligning What EEG Can See: Structural Representations for Brain-Vision Matching

Visual decoding from electroencephalography (EEG) has emerged as a highly promising avenue for non-invasive brain-computer interfaces (BCIs). Existing EEG-based decoding methods predominantly align brain signals with the final-layer semantic embeddings of deep visual models. However, relying on these highly abstracted embeddings inevitably leads to severe cross-modal information mismatch. In this work, we introduce the concept of Neural Visibility and accordingly propose the EEG-Visible Layer Selection Strategy, aligning EEG signals with intermediate visual layers to minimize this mismatch. Furthermore, to accommodate the multi-stage nature of human visual processing, we propose a novel Hierarchically Complementary Fusion (HCF) framework that jointly integrates visual representations from different hierarchical levels. Extensive experiments demonstrate that our method achieves state-of-the-art performance, reaching an 84.6% accuracy (+21.4%) on zero-shot visual decoding on the THINGS-EEG dataset. Moreover, our method achieves up to a 129.8% performance gain across diverse EEG baselines, demonstrating its robust generalizability.
Oct 18, 2026

NeuroAct: Advancing EEG Analysis and Decoding via Dual-Loop Autonomous Research

EEG analysis and decoding underpin brain-computer interfaces, cognitive assessment, and sleep monitoring. Fixed pipelines and reward-driven search do not explicitly determine how signal structure, representations, predictor behavior, and training dynamics contribute to performance or generalization gaps, leaving intervention choice underdetermined. We introduce NeuroAct, an autonomous research agent framework for EEG analysis and decoding. NeuroAct implements dual-loop autonomous research across EEG foundation models, task-specific predictors, and model combinations. In an inner loop, research, development, and review roles use evidence on signal structure, representations, predictor behavior, and training dynamics to test hypotheses, select analyses or interventions, and refine candidates using performance, stability, and cost feedback. An outer loop distills outcomes into conditional, testable recommendations with task and model conditions, then validates and revises them on subsequent tasks.We evaluate four settings: (A) EEG General Analysis, (B) Cross-task Model Optimization, (C) Single-task Open Research, and (D) Collaborative Prediction. In Setting A, NeuroAct's 80.88 macro-average exceeds BrainAgent's 63.13 by 17.75 points. In Setting B, NeuroAct raises EEGPT's mean balanced accuracy (BA) by 7.34 points and HBN Pearson's (r) from 0.6894 to 0.7362; in Setting C, it improves ADFTD BA by 16.33 points; and in Setting D, it raises Workload BA from 79.69% to 85.02%. Experience reuse raises BCIC-IV-2a BA from 34.66% to 50.81% while reducing LLM tokens by 64.02%, indicating recommendations improve cross-task performance. NeuroAct enables evidence-guided EEG research improved by cross-task experience.
May 16, 2026

"I'm Not Mad, Just Focused'': Understanding Human Emotions in Human-Robot Collaboration

Human-robot collaboration (HRC) can benefit from robots' abilities to interpret human emotional states. However, current emotion recognition (ER) models in HRC often fall short, particularly due to their reliance on acted datasets and single-modality inputs like facial expressions. We propose a novel vision language model (VLM)-based ER system that leverages contextual understanding to improve emotion interpretation in HRC. We first evaluate the VLM-ER system by assessing its semantic and sentiment similarity with human annotations on an existing HRC dataset. Then, in a user study with a service robot in a collaborative delivery task, we evaluate the effects of modulating the robot's behaviour based on the user's emotional state inferred by the VLM-ER system. The results show that the proposed VLM-ER system achieves higher semantic similarity and positive sentiment alignment with human annotations compared to a baseline convolutional neural network-based system. Further, participants in the user study preferred emotion-adaptive robot behaviour facilitated by the VLM-ER system.