eess.SPApr 15, 2024

TransfoRhythm: A Transformer Architecture Conductive to Blood Pressure Estimation via Solo PPG Signal Capturing

Authors: Amir Arjomand, Amin Boudesh, Farnoush Bayatmakou, Kenneth B. Kent, Arash Mohammadi

Organizations: Faculty of Computer Science, University of New Brunswick, Fredericton, New Brunswick, Canada · Concordia Institute for Information Systems Engineering, Concordia University, Montreal, Quebec, Canada

Abstract

Recent statistics indicate that approximately 1.3 billion individuals worldwide suffer from hypertension, a leading cause of premature death globally. Blood Pressure (BP) serves as a critical health indicator for accurate and timely diagnosis and/or treatment of hypertension. Traditional BP measurement methods rely on cuff-based approaches, which lack real-time, continuous, and reliable BP estimates, crucial for the timely diagnosis/treatment of hypertension. Driven by recent advancements in Artificial Intelligence (AI) and Deep Neural Networks (DNNs), there has been a surge of interest in developing data-driven and cuff-less BP estimation solutions. In this context, current literature predominantly focuses on coupling Electrocardiography (ECG) and Photoplethysmography (PPG) sensors, though this approach is constrained by reliance on multiple sensor types. An alternative, utilizing standalone PPG signals, presents challenges due to the absence of auxiliary sensors (ECG), requiring the use of morphological features while addressing motion artifacts and high-frequency noise. To address these issues, the paper introduces the TransfoRhythm framework, a Transformer-based DNN architecture built upon the recently released physiological database, MIMIC-IV. Leveraging the Multi-Head Attention (MHA) mechanism, TransfoRhythm identifies dependencies and similarities across data segments, forming a robust framework for cuff-less BP estimation solely using PPG signals. To our knowledge, this paper represents the first study to apply the MIMIC IV dataset for cuff-less BP estimation. TransfoRhythm achieves highly accurate results with a Root Mean Square Error (RMSE) of [2.21, 1.84] and a Mean Absolute Error (MAE) of [1.37, 1.06] for systolic and diastolic blood pressures, respectively.

Figures & tables

Explore similar work

CardsList
  1. DMT: Demographic Conditioning, Morphology-Enhanced Transformer for Cuffless Blood Pressure Estimation from PPG Signals

    Jun 9, 2026Yidan Shen, Neville Mathew, Maham Rahimi +4PhotoplethysmographyWearable Health Monitoring

  2. Single-Beat Cuffless Blood Pressure Estimation Using Ear-PPG and ECG with a Lightweight Hybrid Learning Framework

    Jul 29, 2026Kindeep K. Dhatt, Tengyue Wu, Hanbang Hua +1Wearable Health MonitoringCuffless Blood Pressure Estimation

  3. A Multidimensional Data-Driven Hybrid Transformer Framework for Non-invasive Continuous Blood Pressure Prediction

    Aug 24, 2026Yuexin Ma, Jingqi Hou, Yuxuan Kang +1Wearable Health MonitoringTime Series Transformers