cs.CVDec 12, 2024

How Well Can Modern LLMs Act as Agent Cores in Radiology Environments?

Authors: Qiaoyu ZhengChaoyi WuWeike ZhaoPengcheng QiuLisong DaiYa ZhangYanfeng WangWeidi Xie

Abstract

Radiology, with its heterogeneous modalities, anatomies, and evolving protocols, is a natural yet high-stakes testbed for agentic AI. As LLMs grow more capable and tool ecosystems such as MCP and Agent Skills more complex, their capability boundaries in radiology remain unclear. We introduce RadA-BenchPlat, a two-layer benchmark spanning idealized reasoning and real-world execution: a synthetic layer with 2.2k clinician-verified records, 24.2k QA pairs, and 10 tool categories under diverse availability settings; and a real-environment layer pairing 165 2D/3D cases with executable tools for grounding, diagnosis, and report generation. We find that high completion rates under idealized settings do not carry over to real environments, where the best agents trail their upper bound by approximately 15% and drop to 0.327 on long-chain tasks. Prompting strategies (few-shot exemplars, multi-agent coordination) and AutoTB (on-the-fly synthesis of missing tools) mitigate execution drift and breakdowns in difficult scenarios, lifting execution success to 94.5%, yet remain not fully reliable. Overall, our findings suggest that radiology agents are no longer limited to conceptual demonstrations, but are beginning to show potential for real-world applications. Project repository: https://github.com/MAGIC-AI4Med/RadABench

Explore similar work

May 11, 2026cs.CV

ABRA: Agent Benchmark for Radiology Applications

Existing medical-agent benchmarks deliver imaging as pre-selected samples, never as an environment the agent must navigate. We introduce ABRA, a radiology-agent benchmark in which the agent operates an OHIF viewer and an Orthanc DICOM server through twenty-one function-calling tools that span slice navigation, windowing, series selection, pixel-coordinate annotation, and structured reporting. ABRA contains 655 programmatically generated tasks across three difficulty tiers and eight types (viewer control, metadata QA, vision probe, annotation, longitudinal comparison, BI-RADS reporting, and oracle variants of annotation and BI-RADS reporting), drawn from LIDC-IDRI, Duke Breast Cancer MRI, and NLST New-Lesion LongCT. Each episode is scored along Planning, Execution, and Outcome (Bluethgen et al., 2025) by task-type-specific automatic scorers. Ten current models, five closed-weight and five open-weight, reach at least 89% Execution on real annotation but only 0-25% Outcome; on the paired oracle variant where a simulated detector supplies the finding, Outcome on the same task reaches 69-100% across the models evaluated, localising the bottleneck to perception rather than tool orchestration. Code, task generators, and scorers are released at https://github.com/Luab/ABRA
Bulat Maksudov, Vladislav Kurenkov, Kathleen M. Curran +1
May 4, 2026cs.AI

PhysicianBench: Evaluating LLM Agents in Real-World EHR Environments

We introduce PhysicianBench, a benchmark for evaluating LLM agents on physician tasks grounded in real clinical setting within electronic health record (EHR) environments. Existing medical agent benchmarks primarily focus on static knowledge recall, single-step atomic actions, or action intent without verifiable execution against the environment. As a result, they fail to capture the long-horizon, composite workflows that characterize real clinical systems. PhysicianBench comprises 100 long-horizon tasks adapted from real consultation cases between primary care and subspecialty physicians, with each task independently reviewed by a separate panel of physicians. Tasks are instantiated in an EHR environment with real patient records and accessed through the same standard APIs used by commercial EHR vendors. Tasks span 21 specialties (e.g., cardiology, endocrinology, oncology, psychiatry) and diverse workflow types (e.g., diagnosis interpretation, medication prescribing, treatment planning), requiring an average of 27 tool calls per task. Solving each task requires retrieving data across encounters, reasoning over heterogeneous clinical information, executing consequential clinical actions, and producing clinical documentation. Each task is decomposed into structured checkpoints (670 in total across the benchmark) capturing distinct stages of completion graded by task-specific scripts with execution-grounded verification. Across 13 proprietary and open-source LLM agents, the best-performing model achieves only 46% success rate (pass@1), while open-source models reach at most 19%, revealing a substantial gap between current agent capabilities and the demands of real-world clinical workflows. PhysicianBench provides a realistic and execution-grounded benchmark for measuring progress toward autonomous clinical agents.
Ruoqi Liu, Imran Q. Mohiuddin, Austin J. Schoeffler +10
Apr 16, 2026cs.AI

RadAgent: A tool-using AI agent for stepwise interpretation of chest computed tomography

Vision-language models (VLM) have markedly advanced AI-driven interpretation and reporting of complex medical imaging, such as computed tomography (CT). Yet, existing methods largely relegate clinicians to passive observers of final outputs, offering no interpretable reasoning trace for them to inspect, validate, or refine. To address this, we introduce RadAgent, a tool-using AI agent that generates CT reports through a stepwise and interpretable process. Each resulting report is accompanied by a fully inspectable trace of intermediate decisions and tool interactions, allowing clinicians to examine how the reported findings are derived. In our experiments, we observe that RadAgent improves chest CT report generation over its 3D VLM counterpart, CT-Chat, across three dimensions. Clinical accuracy improves by 5.8 points (35.4% relative) in macro-F1 and 5.1 points (18.6% relative) in micro-F1. Robustness under adversarial conditions improves by 24.7 points (41.9% relative). Furthermore, RadAgent achieves 37.0% in faithfulness, a new capability entirely absent in its 3D VLM counterpart. By structuring the interpretation of chest CT as an explicit, tool-augmented and iterative reasoning trace, RadAgent brings us closer toward transparent and reliable AI for radiology.
Mélanie Roschewitz, Kenneth Styppa, Yitian Tao +10