cs.CVDec 23, 2024

WildPPG: A Real-World PPG Dataset of Long Continuous Recordings

Authors: Manuel Meier, Berken Utku Demirel, Christian Holz

Organizations: Department of Computer Science, ETH Zürich, Switzerland

Abstract

Reflective photoplethysmography (PPG) has become the default sensing technique in wearable devices to monitor cardiac activity via a person's heart rate (HR). However, PPG-based HR estimates can be substantially impacted by factors such as the wearer's activities, sensor placement and resulting motion artifacts, as well as environmental characteristics such as temperature and ambient light. These and other factors can significantly impact and decrease HR prediction reliability. In this paper, we show that state-of-the-art HR estimation methods struggle when processing representative data from everyday activities in outdoor environments, likely because they rely on existing datasets that captured controlled conditions. We introduce a novel multimodal dataset and benchmark results for continuous PPG recordings during outdoor activities from 16 participants over 13.5 hours, captured from four wearable sensors, each worn at a different location on the body, totaling 216,hours. Our recordings include accelerometer, temperature, and altitude data, as well as a synchronized Lead I-based electrocardiogram for ground-truth HR references. Participants completed a round trip from Zurich to Jungfraujoch, a tall mountain in Switzerland over the course of one day. The trip included outdoor and indoor activities such as walking, hiking, stair climbing, eating, drinking, and resting at various temperatures and altitudes (up to 3,571,m above sea level) as well as using cars, trains, cable cars, and lifts for transport -- all of which impacted participants' physiological dynamics. We also present a novel method that estimates HR values more robustly in such real-world scenarios than existing baselines.

Figures & tables

Appendix figures & tables2 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

May 18, 2026

Multi-site PPG: An In-the-Wild Physiological Dataset from Emerging Multi-site Wearables

Wearables are widely used for mobile health monitoring, and photoplethysmography (PPG) is a key sensing modality for heart rate and related physiological measurements. However, public in-the-wild PPG datasets remain largely wrist-centric or limited to short, controlled studies, constraining research on emerging wearable form factors. We present Multi-site PPG, an in-the-wild physiological dataset collected from four custom-developed unobtrusive wearables: a smart earring, ring, watch, and necklace. Each device records green and infrared reflective PPG, 3-axis acceleration, and temperature with timestamps for cross-device alignment, while a Polar H10 chest strap provides reference electrocardiogram (ECG). Participants wore the devices for multiple days during daytime activities while continuing their normal routines. The dataset contains over 350 hours of raw data and 230-290 hours of modeling-ready 8-second windows per wearable. We benchmark heuristic, supervised, and self-supervised heart-rate estimation methods, showing substantial body-site differences: the best methods achieve mean absolute errors (MAEs) of 2.30 bpm on the earring, 5.13 bpm on the ring, 8.37 bpm on the watch, and 8.68 bpm on the necklace. We further analyze motion effects and evaluate multi-site and PPG-accelerometer fusion, demonstrating the dataset's value for robust physiological sensing across emerging wearable form factors.
Jun 5, 2026

A robust PPG foundation model using multimodal physiological supervision

Photoplethysmography (PPG), a non-invasive measure of changes in blood volume, is widely used in both wearable devices and clinical settings. Recent PPG foundation models either use open-source ICU datasets with pretraining paradigms that require curated data and thus complicate generalization to field-like data, or use closed-source field-like PPG data. In contrast, we propose a PPG foundation model that does not require high-quality or field-like pretraining data, and instead leverages accompanying electrocardiogram and respiratory signals in ICU datasets to select contrastive samples during pretraining. Our approach allows the model to retain and learn from noisy PPG segments, improving robustness at inference. Our model, pretrained on 3x fewer subjects than existing state-of-the-art approaches, achieves performance improvements on 14 out of 15 diverse downstream tasks, including field-like daily activity and heart rate prediction. Our results demonstrate that multimodal supervision can integrate complementary physiological information to improve the robustness of PPG foundation models and enhance their generalization to consumer-grade data.
Oct 9, 2026

PPG-Bench: A Unified Benchmark for PPG Foundation Models

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.