Radiotherapy (RT) planning is complex, subjective, and time-intensive. Advances with artificial intelligence (AI) promise to improve its precision and efficiency, but progress is often limited by the scarcity of large, standardized datasets. To address this, we introduce the Automated Iterative RT Planning (AIRTP) system, a scalable solution for generating high-quality treatment plans. This scalable solution is designed to generate substantial volumes of consistently high-quality treatment plans, overcoming a key obstacle in the advancement of AI-driven RT planning. Our AIRTP pipeline adheres to clinical guidelines and automates essential steps, including organ-at-risk (OAR) contouring, helper structure creation, beam setup, optimization, and plan quality improvement, using AI integrated with RT planning software like Varian Eclipse. Furthermore, a novel approach for determining optimization parameters to reproduce 3D dose distributions, i.e. a method to convert dose predictions to deliverable treatment plans constrained by machine limitations is proposed. A comparative analysis of plan quality reveals that our automated pipeline produces treatment plans of quality comparable to those generated manually, which traditionally require several hours of labor per plan. Committed to public research, the first data release of our AIRTP pipeline includes nine cohorts covering head-and-neck and lung cancer sites to support an AAPM 2025 challenge. To our best knowledge, this dataset features more than 10 times number of plans compared to the largest existing well-curated public dataset. Repo: https://github.com/RiqiangGao/GDP-HMM_AAPMChallenge.

Explore similar work

May 30, 2026physics.med-ph

A Machine-to-Machine Knowledge-Guided LLM Agent for Generalizable Radiotherapy Treatment Planning

In this work, we propose a prototype machine-to-machine (M2M) knowledge-guided Large Language Model (LLM) framework for automated radiotherapy treatment planning. In the proposed paradigm, Treatment Planning Parameter (TPP) distribution knowledge discovered by a Deep Reinforcement Learning (DRL) agent is transferred to an LLM agent through in-context learning, enabling autonomous iterative planning without human intervention. While standard LLM-based planning often lacks physical intuition and struggles with convergence, the integration of DRL-derived guidance constrains the agent to a physically valid parameter space. Experimental evaluations are performed across three diverse planning scenarios: basic prostate cases, complex prostate configurations with increased organ-at-risk (OAR) constraints, and liver cases. The evaluation results demonstrate that the guided LLM agent consistently achieves optimal planning scores while significantly reducing the number of iterations compared to unguided planning. Analysis of the final TPP configurations reveals that the agent successfully learns a hierarchical priority of objectives, effectively restoring a logical "cause-and-effect" relationship between parameter tuning and dosimetric outcomes. Crucially, this prototype framework exhibits robust generalizability, maintaining high planning quality regardless of specific patient anatomy, treatment site, or initial plan quality. By bridging the specialized optimization of DRL with the adaptive reasoning of LLMs, this M2M framework establishes a scalable foundation towards generalizable autonomous treatment planning, ultimately benefiting clinical practice in realistic environments.
Md Mainul Abrar, Xun Jia, Yujie Chi
May 13, 2026cs.CV

Learning to Optimize Radiotherapy Plans via Fluence Maps Diffusion Model Generation and LSTM-based Optimization

Volumetric Modulated Arc Therapy (VMAT) is a cornerstone of modern radiation therapy, enabling highly conformal tumor irradiation and healthy-tissue sparing. Yet, its planning solves inverse and nested optimization for multi-leaf collimators, monitor units and dose parameters, while enforcing their consistency to ensure mechanical deliverability. Nevertheless, this process often requires repeated re-optimization when treatment configurations change, resulting in substantial planning time per patient. To address these problems, we present a diffusion-driven Learning-to-Optimize (L2O) method for end-to-end VMAT planning. A distribution-matching distilled diffusion model learns a clinically feasible manifold of fluence maps, enabling their one-shot generation. On top of this, an LSTM-based L2O module learns gradient update dynamics to swiftly refine fluence maps toward prescribed dose objectives during inference. Experimental results on clinical and public prostate cancer cohorts demonstrate improved planning efficiency, flexibility, and machine deliverability over currently available end-to-end VMAT planners.
Isabella Poles, Simon Arberet, Riqiang Gao +5
Jul 11, 2026eess.IV

BAT-RM: A Boundary-Aware Transformer with Region-Aware Multi-Directional Mamba for Clinically Deployed Cervical Cancer Radiotherapy Auto-Contouring

We present a clinically deployed end-to-end auto-contouring system for cervical cancer radiotherapy planning, anchored by the Boundary-Aware Transformer with Region-Aware Mamba (BAT-RM), a hybrid architecture that integrates Sobel-gated boundary attention, a linear-time, multi-directional Mamba module for long-range context, and a boundary-skeleton-guided fusion gate. This design achieves linear-time complexity for long-range context modeling, avoiding the quadratic cost of full spatial self-attention. The full pipeline spans multi-institutional data collection, rigorous inter-rater quality assurance, external validation in an independent cohort, and a web-based clinical interface natively compatible with Varian, RayStation, and Monaco. Against four baselines, BAT-RM achieves superior performance across seven anatomical classes, with statistically significant improvements in target volumes, including GTV and CTV, and in organs at risk such as the rectum and bladder. A prospective multi-center reader study involving 13 radiation oncologists demonstrated that AI assistance elevates junior oncologists' IoU from 0.899 to 0.965, approaching senior-level accuracy, while reducing contouring time by more than 80%. The system also reduced expert consultation rates and improved inter-reader consistency, reflecting gains in both efficiency and quality assurance. Following clinical deployment at a partner hospital, the system reduced patient wait times from days to hours without additional staffing, enabling same-day or next-day initiation of treatment for routine cases. BAT-RM demonstrates that a rigorous research pipeline, from data curation to clinical deployment, can translate directly into measurable patient benefit in resource-constrained settings where the demand for radiotherapy far exceeds specialist capacity.
Istiak Ahmed, Kazi Shahriar Sanjid, Galib Ahmed +16