cs.CVAug 5, 2025

SSFMamba: Learning Symmetry-driven Spatial-Frequency Modeling for Physically Consistent 3D Medical Image Segmentation

Authors: Bo Zhang, Yifan Zhang, Shuo Yan, Yu Bai, Zheng Zhang, Wu Liu, Xiuzhuang Zhou, Wendong Wang

Organizations: State Key Laboratory of Networking and Switching Technology, School of Computer Science (National Pilot Software Engineering School), Beijing University of Posts and Telecommunications. · School of Intelligent Engineering and Automation, Beijing University of Posts and Telecommunications. · School of Information Science and Technology, University of Science and Technology of China.

Abstract

Accurate 3D medical image segmentation requires a delicate balance between fine-grained local details and global contextual understanding. While spatial-domain models often struggle with long-range dependencies, existing frequency-based approaches frequently overlook intrinsic spectral properties such as Hermitian symmetry, leading to suboptimal feature integration. In this paper, we propose SSFMamba, a Mamba-based Symmetry-driven Spatial-Frequency fusion framework tailored for 3D medical imaging. Our architecture employs a complementary dual-branch design: the spatial branch models voxel sequences to preserve intricate anatomical textures, while the frequency branch operates on spectral components, each of which aggregates information from the entire volume, to capture global context. A core innovation is the 3D Multi-Directional Scanning Mechanism (MDSM), which integrates Hermitian symmetry with the causal nature of State Space Models (SSMs) to enable direction-aware global modeling. Crucially, by shifting the modeling focus to frequency-domain spectral components, SSFMamba captures the underlying structural characteristics of anatomical tissues. This leads to a highly adaptable framework that excels in both MRI and CT applications, regardless of the significant variations in intensity distributions. Extensive evaluations on the BraTS2020, BraTS2023, and BTCV datasets demonstrate that SSFMamba consistently outperforms state-of-the-art methods. Notably, our approach achieves exceptional performance on low-contrast organs such as the pancreas (81.97% Dice), underscoring its potential as a unified and physically consistent perception framework for diverse 3D clinical applications.

Figures & tables

Explore similar work

May 29, 2026

BiSegMamba: Efficient Bidirectional Tri-Oriented Mamba for 3D Medical Image Segmentation

Accurate 3D medical image segmentation requires both long-range volumetric context and fine boundary preservation. CNN-based methods have limited global dependency modeling, while Transformer-based models are often computationally expensive for dense 3D inputs. Recent Mamba-based methods provide an efficient alternative, but existing volumetric designs still depend on repeated high-resolution scanning, forward-only sequential modeling, and fixed directional summation, causing high cost, scan-order bias, and suboptimal directional aggregation. We propose BiSegMamba, an efficient bidirectional tri-oriented Mamba network for 3D medical image segmentation. BiSegMamba follows a compact-to-detail design, where a progressive compacting stem (PCS) enables efficient latent-space reasoning while retaining shallow high-resolution features for reconstruction. A multi-scale spatial mixer (MSSM) captures local anatomical patterns in early stages, and the proposed bidirectional tri-oriented Ortho Mamba (Bi-ToOM) block models long-range dependencies from multiple orthogonal views using jointly processed forward and backward scan sequences. Adaptive directional fusion (ADF) learns input-dependent channel-wise weights across scan orientations, replacing fixed summation with orientation-aware fusion. Experiments on a collected carotid CTA dataset and three public benchmarks, BraTS2023, ACDC, and AMOS-CT, show that BiSegMamba generalizes well across vascular, cardiac, brain tumor, and abdominal multi-organ segmentation tasks. Compared with SegMamba-V2, BiSegMamba achieves slightly better performance on BraTS2023 and clear improvements on ACDC and the carotid dataset, while reducing computational cost by up to 77.9% FLOPs, demonstrating a strong accuracy-efficiency balance for general 3D medical image segmentation.
Feb 26, 2026

SpectralMamba-UNet: Frequency-Disentangled State Space Modeling for Texture-Structure Consistent Medical Image Segmentation

Accurate medical image segmentation requires effective modeling of both global anatomical structures and fine-grained boundary details. Recent state space models (e.g., Vision Mamba) offer efficient long-range dependency modeling. However, their one-dimensional serialization weakens local spatial continuity and high-frequency representation. To this end, we propose SpectralMamba-UNet, a novel frequency-disentangled framework to decouple the learning of structural and textural information in the spectral domain. Our Spectral Decomposition and Modeling (SDM) module applies discrete cosine transform to decompose low- and high-frequency features, where low frequency contributes to global contextual modeling via a frequency-domain Mamba and high frequency preserves boundary-sensitive details. To balance spectral contributions, we introduce a Spectral Channel Reweighting (SCR) mechanism to form channel-wise frequency-aware attention, and a Spectral-Guided Fusion (SGF) module to achieve adaptively multi-scale fusion in the decoder. Experiments on five public benchmarks demonstrate consistent improvements across diverse modalities and segmentation targets, validating the effectiveness and generalizability of our approach.
Mar 23, 2026

SegMaFormer: A Hybrid State-Space and Transformer Model for Efficient Segmentation

The advent of Transformer and Mamba-based architectures has significantly advanced 3D medical image segmentation by enabling global contextual modeling, a capability traditionally limited in Convolutional Neural Networks (CNNs). However, state-of-the-art Transformer models often entail substantial computational complexity and parameter counts, which is particularly prohibitive for volumetric data and further exacerbated by the limited availability of annotated medical imaging datasets. To address these limitations, this work introduces SegMaFormer, a lightweight hybrid architecture that synergizes Mamba and Transformer modules within a hierarchical volumetric encoder for efficient long-range dependency modeling. The model strategically employs Mamba-based layers in early, high-resolution stages to reduce computational overhead while capturing essential spatial context, and reserves self-attention mechanisms for later, lower-resolution stages to refine feature representation. This design is augmented with generalized rotary position embeddings to enhance spatial awareness. Despite its compact structure, SegMaFormer achieves competitive performance on three public benchmarks (Synapse, BraTS, and ACDC), matching the Dice coefficient of significantly larger models. Empirically, our approach reduces parameters by up to 75x and substantially decreases FLOPs compared to current state-of-the-art models, establishing an efficient and high-performing solution for 3D medical image segmentation.